(MQQSC068) Quartz Screw-Top Cuvette, 40/10 mm paths, Long Low Chamber
$948.00
Quartz Screw-Top Cuvette for UV/Vis spectroscopy with a 40 mm primary path, 10 mm secondary path and five-sided optical windows. Its 4 mL nominal capacity and GL14 screw-top neck suit methods that need a longer optical path with top filling and closure. Sold as 1 piece with accompanying closure.
Description
MQQSC068 is a JGS1 quartz screw-top cuvette for UV/Vis spectroscopy with a 40 mm primary path and a 10 mm secondary path. The five-sided optical window layout gives additional optical access around the sample chamber, while the GL14 threaded neck keeps filling and closure at the top of the cell. With a 4 mL nominal capacity, it suits methods that need a longer path in a larger filled chamber.
This version is supplied as one cuvette with an accompanying closure. The listed body dimensions apply to the bare optical body, while the overall height with cap is separate and important for holder clearance.
- Path Length
- 40 mm / 10 mm (dual path)
- Sample Volume (Nominal)
- 4 mL
- Opening Configuration
- Single Threaded Neck
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Screw-Top Cuvette |
| Measurement Mode | UV/Vis Spectroscopy |
| Path Length | 40 mm / 10 mm (dual path) |
| Light Transmission Configuration | Five-Sided Optical Windows |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 4 mL |
| Cell Body Dimensions | 42.5 × 12.5 × 12.5 mm |
| Overall Height without Closure | 47 mm |
| External Dimensions Scope | Body Only |
| Overall Height with Closure | 52 mm |
| Material | Quartz |
| Material Grade | JGS1 |
| Closure Type | Screw Cap |
| Closure Material | PTFE |
| Closure Included | Yes |
| Fabrication Method | Molded 83 |
| Opening Configuration | Single Threaded Neck |
| Closure Thread | GL14 |
| Pack Quantity | 1 Piece |
| Package Contents | 1 × Quartz Screw-Top Cuvette; Accompanying PTFE screw cap |
Choose this option
Choose MQQSC068 when your method is built around a 40 mm measurement path and you also want the extra 10 mm path available in the same cell format. The screw-top GL14 neck is useful where you want top access for filling and recapping, and the five-sided optical layout can help in setups that need more than one viewing direction around the chamber.
What makes this option different
- Dual path geometry: 40 mm primary path with 10 mm secondary path for methods that use this defined cell orientation.
- Five-sided optical windows: extra optical access around the chamber beyond a simple two-face layout.
- GL14 screw-top neck: top filling and closure are part of the installed geometry and matter for overhead clearance.
- 4 mL nominal capacity: a larger sample chamber than a low-volume micro cuvette format.
Using this cell
Fill the cell through the threaded top opening, then fit the closure before measurement as required by your procedure. Keep the orientation consistent between blank and sample so the intended path and window faces stay the same throughout the run.
Before reading, make sure the illuminated region is fully covered and that no bubbles remain in the active optical area. After filling or recapping, wipe the outside optical faces so droplets do not remain on the windows.
First-use check
- Inspect the optical faces, neck and closure seating area for chips, residue or transport dust.
- Place the cell in the holder and confirm that the beam uses the intended window pair in the chosen orientation.
- Run a blank in the same orientation you will use for sample measurements.
Fit and optical alignment
View the English selection reference. Also available in the product gallery.
The bare optical body is 42.5 × 12.5 × 12.5 mm, while the overall height with cap is 52 mm. Check both the holder cavity and the vertical space needed for the neck and closure, because the body dimensions do not describe the full installed envelope.
Z Height is not established for this SKU. If your holder or instrument depends on a defined beam-center height, check that requirement before ordering.

Solvents and cleaning
Molded 83 quartz is often selected for methods involving organic solvents or elevated-temperature work, but suitability depends on the complete cell assembly, including the closure and your actual process conditions.
Do not use hydrofluoric acid with quartz. Avoid hot strong alkalis and abrasive cleaning materials. If your sample or cleaning routine is chemically demanding, check the exact liquid, concentration, temperature and contact time for this assembled configuration before use.
Included with this option
1 Quartz Screw-Top Cuvette with accompanying closure. The listed price is for one piece.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We coordinate custom JGS1 quartz production for requirements involving dimensions, optical path length, sample volume, optical windows, closures and tolerances. Modified designs and prototype batches are quoted separately from the listed SKU.
Send a product-selection enquiry with SKU MQQSC068, your holder details or drawing, sample conditions, quantity and delivery destination.
Additional information
| Weight | 75 g |
|---|
You must be logged in to post a review.














Reviews