(MQQST011) JGS1 Quartz Cylindrical Cell, 1 mm Path, 57 mm OD
$828.00
JGS1 quartz cylindrical cell with a 1 mm optical path in a large round-body format for UV/Vis work. This version combines a 57 mm outer diameter disc, a 50 mm internal diameter sample region and a stoppered filling neck for setups built around circular cell geometry rather than a square cuvette footprint. Supplied as 1 piece with stopper.
Description
MQQST011 is a JGS1 quartz cylindrical cell for UV/Vis spectroscopy with a 1 mm optical path and a broad circular body. Its 57 mm outer diameter, 50 mm internal diameter and stoppered neck make it a specialist choice when your holder supports a round disc format and you need direct top filling without changing to a rectangular cuvette style.
- Path Length
- 1 mm
- Cell Type
- Cylindrical Cell
- Opening Configuration
- Stoppered Filling Neck
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Cylindrical Cell |
| Measurement Mode | UV/Vis Spectroscopy |
| Path Length | 1 mm |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Overall Height without Closure | 66 mm |
| External Depth | 3.5 mm |
| Overall Height with Closure | 69 mm |
| Internal Dimensions | 50 × 1 mm |
| Outer Diameter (OD) | 57 mm |
| Inner Diameter (ID) | 50 mm |
| Material | Quartz |
| Material Grade | JGS1 |
| MQ Grade | Molded 83 |
| Closure Type | Stopper |
| Closure Included | Yes |
| Fabrication Method | Molded 83 |
| Opening Configuration | Stoppered Filling Neck |
| Pack Quantity | 1 Piece |
| Package Contents | 1 × Cylindrical Cell; Stopper included |
Choose this option
Choose this cell when your method needs a 1 mm path in a circular body rather than a standard square cuvette. The wide disc format is useful where the support or fixture locates the cell by its round body, and the stoppered neck gives a simple way to fill, close and reopen the cell from above during routine UV/Vis handling.
What makes this option different
- 1 mm optical path in a cylindrical cell format, not a standard rectangular cuvette body.
- 57 mm outer diameter disc with 3.5 mm external thickness for holder and support planning.
- 50 mm internal diameter creates a wide circular sample region separate from the optical path dimension.
- Stoppered filling neck included, with 66 mm overall height without the stopper and 69 mm with it fitted.
Using this cell
Fill through the neck and fit the stopper after the sample region is covered and free of visible bubbles in the beam area. For repeatable measurements, keep the same orientation for blank and sample. Support the body securely while keeping fingers off the optical faces.
Support the round body during filling and transfer. Do not rely on the neck alone to carry the cell, and avoid clamping or point pressure on the disc edge.
The separate stopper lets you cover the filling opening between handling steps without taking the disc body apart. It does not establish an airtight or pressure-rated seal. Stopper material and joint size are not specified for this option; check these details with us if they are critical to your sample chemistry or fixture.
First-use check
- Inspect the optical faces, disc edge, neck and stopper for chips, residue or shipping damage.
- Place the cell in the intended support and confirm that the round body seats securely without edge stress.
- Run a blank at your intended fill level and confirm that the illuminated region is fully covered and bubble-free.
Fit and optical alignment
Plan mechanical fit from the actual body geometry: 57 mm outer diameter, 3.5 mm disc thickness, 66 mm overall height without the stopper and 69 mm with the stopper in place. Leave enough clearance above the neck for filling, stopper insertion and removal.
The 1 mm value is the optical path. The 50 mm internal diameter describes the circular sample region and should not be treated as beam height, optical aperture or holder reference height. Z Height is not specified for this model, so if your instrument depends on a defined beam-center height, that should be checked against your holder before ordering.
View the English selection reference. Also available in the product gallery.

Solvents and cleaning
This cell is listed as Molded 83. This fabrication is commonly chosen for methods that may involve organic solvents or elevated-temperature measurement conditions, but suitability still depends on the actual liquid, concentration, temperature, contact time and the complete wetted assembly.
Do not use hydrofluoric acid with quartz. Avoid hot strong alkalis, abrasive cleaners and mechanical stress on the body or neck. Clean the optical faces gently with suitable non-abrasive optical tissue.
Included with this option
1 MQQST011 cylindrical cell with stopper. Price is for one cell.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
If you need a different disc diameter, path length, neck arrangement or support geometry, send a holder drawing or a labelled sketch with the critical fit dimensions, beam position, sample liquid and target quantity.
Custom enquiries generally use JGS1 quartz, and prototype batches typically involve 2–4 cells. Feasibility, final specifications, price and production time are confirmed in the project quotation. Send a product-selection enquiry and quote MQQST011.
Design notes for this configuration: Thin Circular Quartz Cell: Filling a Wide Window through a Narrow Gap
Additional information
| Weight | 50 g |
|---|
You must be logged in to post a review.








Reviews
There are no reviews yet.