(C1004CS) Quartz Fluorescence Cuvette, 100 mm / 10 mm (dual path) Path, 35 mL
Original price was: $751.00.$676.00Current price is: $676.00.
C1004CS is a JGS1 quartz fluorescence cuvette with a 100 mm primary optical path, a stated 10 mm secondary path and Four-Way Light access. Its long open-top body and 35 mL nominal capacity suit methods that need an extended path length in a larger sample cell. Supplied as 1 cuvette per price unit.
Description
C1004CS is a JGS1 quartz fluorescence cuvette built around a 100 mm primary optical path, with a stated secondary 10 mm path in the same cell. The long open-top body provides Four-Way Light access and a 35 mL nominal capacity, making this a larger-format option for fluorescence work where the extended path is the main reason to choose the cell. This sale option is supplied as 1 cuvette.
- Path Length
- 100 mm / 10 mm (dual path)
- Sample Volume (Nominal)
- 35 mL
- Opening Configuration
- Open Top
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Fluorescence Cuvette |
| Measurement Mode | Fluorescence Spectroscopy |
| Path Length | 100 mm / 10 mm (dual path) |
| Light Transmission Configuration | Four-Way Light |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 35 mL |
| External Dimensions | 102.5 × 12.5 × 45 mm |
| Uncapped Cell Dimensions | 102.5 × 12.5 × 45 mm |
| External Dimensions Scope | Uncapped Cell |
| Body Height | 45 mm |
| Base Dimensions | 102.5 × 12.5 mm |
| Material | Quartz |
| Material Grade | JGS1 |
| Opening Configuration | Open Top |
Choose this option
Choose C1004CS when your method specifically requires a long-path fluorescence cuvette and your holder can accommodate a much longer body than standard rectangular cells. The key distinction is not just capacity but geometry: this is a long quartz cell intended for setups built around a 100 mm optical path, with a second stated 10 mm path also part of the design.
What makes this option different
- 100 mm primary optical path with a stated 10 mm secondary path in one cuvette.
- Four-Way Light geometry for fluorescence layouts that use side optical access.
- 35 mL nominal capacity for larger sample volumes than compact fluorescence cells.
- Long open-top body with stated uncapped dimensions of 102.5 × 12.5 × 45 mm.
Using this cell
Fill the cell from the open top and handle it carefully when placing it in the holder so the long body seats evenly without twisting. Keep the optical faces clean in the beam area, and keep the same orientation between blank and sample runs if your measurement depends on a fixed excitation and collection direction.
The stated 35 mL figure is a nominal capacity, not a minimum working volume. If your method depends on a defined fill height, beam coverage or limited sample quantity, check suitability in your own holder and instrument setup before routine use.
First-use check
Before first use, inspect the long optical faces and the top opening for chips, residue or handling marks. Place the empty cell in the holder to confirm full seating and compartment clearance, then run a blank and check that the beam area stays free of bubbles and visible contamination after filling.
Fit and optical alignment
The stated dimensions are for the uncapped cell: 102.5 × 12.5 × 45 mm. Check the sample-compartment length as well as holder slot width, body height and top clearance for filling. This long body may need more clearance than a standard short fluorescence cuvette even when the cross-section fits.
Z Height is not specified for this SKU, so beam-center alignment should not be assumed from overall body height alone. Four-Way Light describes the side optical access arrangement, but instrument fit still depends on your holder geometry and beam position. The stated wavelength range for this cuvette is 200–2500 nm.
Solvents and cleaning
This cuvette is made from JGS1 quartz. For a general overview of cuvette construction options, see Compare fabrication options.
Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaning methods. Clean the optical faces gently with non-abrasive optical tissue or another non-scratching lab wipe suitable for your procedure.
Included with this option
1 cuvette per listed price unit. If you need a supplied closure or other accessory, contact us before ordering.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We coordinate custom JGS1 quartz production for requirements involving dimensions, optical path length, sample volume, optical windows or Z Height, closures and connections, fabrication and tolerances. Send a dimensioned drawing or labelled sketch and identify the dimensions and tolerances that are critical to your application. Prototype batches typically involve 2–4 cells; final specifications, quantity, price and production time are confirmed in the project quotation. Discuss your requirements and quote part number C1004CS.
Additional information
| Weight | 100 g |
|---|
You must be logged in to post a review.








Reviews
There are no reviews yet.