Site Navigation

(C104SS2) Quartz Fluorescence Cuvette, 10 mm Path, 3.5 mL

Weight30 g
SKU: C104SS2

Original price was: $332.00.Current price is: $299.00.

In Stock

JGS1 quartz fluorescence cuvette with a 10 mm optical path, Four-Way Light access and 3.5 mL nominal capacity. Its long single-tube layout keeps the optical body in a standard 12.5 × 12.5 mm footprint while extending access above the cell for filling or connected handling. Sold per 1 piece.

In Stock
Add to Wishlist
Add to Wishlist
SKU: C104SS2 Categories: , , Brand:
Shipping and order support
  • Worldwide delivery to door service, hassle free shipping
  • Contact us for quotation of bulk purchase discount
  • Custom design. Send us graphic drawing for solution
  • POs for Academics. Pay after delivery.
  • Availability and dispatch timing vary by item and quantity. Contact us to confirm timing for your order.

Description

C104SS2 is a JGS1 quartz fluorescence cuvette with a 10 mm optical path, Four-Way Light geometry and 3.5 mL nominal capacity. The optical body stays within a 12.5 × 12.5 mm footprint, while a long single-tube upper section extends the uncapped height to 95 mm, which can help when you need access above the measurement zone for filling, connection routing or fixture clearance.

Path Length
10 mm
Sample Volume (Nominal)
3.5 mL
Opening Configuration
Single Tube Opening

Selection Specifications

Product KindCuvette
Cell TypeFluorescence Cuvette
Measurement ModeUV/Vis Spectroscopy; Fluorescence Spectroscopy
Pack Quantity1 Piece
Path Length10 mm
Light Transmission ConfigurationFour-Way Light
Sample Volume (Nominal)3.5 mL
External Dimensions12.5 × 12.5 × 95 mm
Cell Body Dimensions12.5 × 12.5 × 45 mm
Uncapped Cell Dimensions12.5 × 12.5 × 95 mm
Overall Height without Closure95 mm
External Dimensions ScopeUncapped Cell
MaterialQuartz
Material GradeJGS1
Tube Outer Diameter (OD)8 mm
Opening ConfigurationSingle Tube Opening

Choose this option

Choose C104SS2 when your method uses a 10 mm quartz cell but your setup also benefits from sample access above the body instead of a short open-top format. The single-tube opening gives you a defined upper access point, and the Four-Way Light layout suits UV/Vis spectroscopy and fluorescence work that uses side optical access around the sample region.

What makes this option different

  • Single-tube opening above the cell body gives sample access from the top of the assembly and leaves the optical section below available for holder support.
  • Four-Way Light configuration supports optical access from multiple sides for UV/Vis and fluorescence measurement layouts that use the cell side faces.
  • 10 mm optical path suits methods built around this standard cuvette path length.
  • 3.5 mL nominal capacity provides a larger sample chamber than micro-volume cell formats, while remaining a cuvette-style body rather than a bottle or vial.
  • 12.5 × 12.5 mm body with 95 mm uncapped overall height separates the holder footprint from the extra vertical reach needed above the measurement area.
  • 8 mm tube outer diameter helps you plan the mating tubing, sleeve or clamp space around the upper section.
  • German HEL(L)MA process is the supplier’s construction wording for this cell, identifying the build style used for this SKU without implying a monolithic body, a specific joint mechanism or a separate performance grade.

Using this cell

Fill and handle the cell through the upper tube section, keeping the optical faces clean and the beam area free of bubbles, droplets and residue. In fluorescence work, keep the same cell orientation between blank and sample measurements so the illuminated and observed faces remain consistent.

The nominal 3.5 mL value is the stated cell capacity, not a minimum working volume. If your method depends on liquid height at the beam position, confirm that your actual fill covers the required optical region under your measurement conditions.

First-use check

  1. Inspect the optical faces and the tube opening for dust, residue or handling marks.
  2. Check that the body seats correctly in the holder and that the upper tube section has adequate free space above the mount.
  3. Run a blank with your measurement solvent and confirm that the optical region is fully covered and visibly free of bubbles.

Fit and optical alignment

The cell body is 12.5 × 12.5 × 45 mm, while the full uncapped assembly height is 95 mm. This matters when the holder accepts the lower body but the space above the holder must also accommodate the long tube section for filling, tubing or manual access.

The 8 mm outer diameter on the tube section is useful for selecting nearby fittings or support clearances, but it does not by itself define sealing details, tube inner diameter or flow direction. Z Height is not established here, so this listing does not by itself confirm beam-center fit for a specific fluorimeter or spectrophotometer.

Solvents and cleaning

This cell uses quartz with a supplier-described German HEL(L)MA process construction. That wording identifies the build style for this SKU, but it does not by itself establish a full solvent list for every sample or cleaning condition. If your method involves aggressive chemicals, long soaking steps or unusual cleaning procedures, check suitability for the complete assembled cell before use.

Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaning, and wipe the optical faces gently with non-abrasive optical tissue. For general fabrication background, see MQ Cuvette Fabrication Glossary.

Included with this option

1 cuvette per listed price unit. If you need a supplied closure or other accessory, contact us before ordering.

Availability and ordering

Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.

Discuss a custom version

We can review custom JGS1 quartz versions for changes to dimensions, optical path length, sample volume, optical access, Z Height, closures, connections and tolerance requirements. Send a dimensioned drawing or labelled sketch together with your holder details, measurement method, sample conditions and target quantity.

Discuss your requirements and quote part number C104SS2.

Additional information

Weight30 g

Reviews

There are no reviews yet.

Be the first to review “(C104SS2) Quartz Fluorescence Cuvette, 10 mm Path, 3.5 mL”

You may also like…

10%
(C104SS1) Quartz Flow Cell, 10 mm Path, 4 mL

(C104SS1) Quartz Flow Cell, 10 mm Path, 4 mL

100 g
In Stock
Original price was: $428.00.Current price is: $386.00.
Add to Wishlist
Add to Wishlist
10%
Quartz 10mm Square-Bottom Fluorescence Flow Cuvette, 3.5ml, Molded 83, Four-Way Light, 1pc/ea, C104WE1

Quartz 10mm Square-Bottom Fluorescence Flow Cuvette, 3.5ml, Molded 83, Four-Way Light, 1pc/ea, C104WE1

30 g
In Stock
Original price was: $466.00.Current price is: $420.00.
Add to Wishlist
Add to Wishlist
10%
Quartz 1mm Fluorescence Flow Cuvette, 350ul, Molded 83, Four-Way Light, PTFE Valve, 1pc/ea, C014WE

Quartz 1mm Fluorescence Flow Cuvette, 350ul, Molded 83, Four-Way Light, PTFE Valve, 1pc/ea, C014WE

30 g
In Stock
Original price was: $608.00.Current price is: $548.00.
Add to Wishlist
Add to Wishlist
10%
(C103WS) Quartz Flow Cell, 10 mm Path, 32 µL

(C103WS) Quartz Flow Cell, 10 mm Path, 32 µL

30 g
In Stock
Original price was: $293.00.Current price is: $264.00.
Add to Wishlist
Add to Wishlist
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • SKU
  • Rating
  • Price
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Weight
  • Dimensions
  • Additional information
Click outside to hide the comparison bar
Compare