(C104CS50) Quartz Micro Cuvette, 10 mm / 5 mm (dual path) Path, 1.75 mL
Original price was: $72.00.$65.00Current price is: $65.00.
JGS1 quartz micro cuvette for fluorescence spectroscopy with a 10 mm primary path, 5 mm secondary path and Four-Way Light access. This adhesive-bonded Standard 80 option has a 1.75 mL nominal capacity and is intended for neutral water-based sample conditions rather than acid, alkali or organic-solvent use. Supplied as 1 quartz micro cuvette, with a closure included.
Description
C104CS50 is a JGS1 quartz micro cuvette for fluorescence spectroscopy with a 10 mm primary path, a 5 mm secondary path and Four-Way Light access around the sample region. This version uses adhesive-bonded Standard 80 construction, so it suits neutral water-based sample conditions rather than acid, alkali or organic-solvent work. Its nominal capacity is 1.75 mL, and this sales option is supplied as 1 quartz micro cuvette, with a closure included.
- Path Length
- 10 mm / 5 mm (dual path)
- Sample Volume (Nominal)
- 1.75 mL
- Closure Type
- Lid
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Micro Cuvette |
| Measurement Mode | Fluorescence Spectroscopy |
| Pack Quantity | 1 Piece |
| Path Length | 10 mm / 5 mm (dual path) |
| Light Transmission Configuration | Four-Way Light |
| Optical Window Dimensions | 5 mm |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 1.75 mL |
| External Dimensions | 12.5 × 12.5 × 45 mm |
| Uncapped Cell Dimensions | 12.5 × 12.5 × 45 mm |
| External Dimensions Scope | Uncapped Cell |
| Material | Quartz |
| Material Grade | JGS1 |
| Closure Type | Lid |
| Closure Included | Yes |
| Fabrication Method | Standard 80 |
| Detection Channel Width | 5 mm |
Choose this option
Choose this cuvette when you need the stated 10 mm / 5 mm dual-path fluorescence geometry and your sample conditions fit an adhesive-bonded quartz cell for neutral aqueous work. The four-side optical access supports fluorescence layouts around the sample region, while the chemical limits make this version a practical choice only where water-based handling and cleaning are suitable.
What makes this option different
- 10 mm / 5 mm dual-path geometry for methods using two stated optical directions in one compact cell.
- Four-Way Light configuration for optical access from four sides around the sample region.
- Standard 80 adhesive-bonded construction suited to room-temperature neutral water-based samples and buffers.
- Supplier chemical limits exclude acid, alkali and organic-solvent use, including ethanol soaking or rinsing.
Using this cell
Fill the cell so the illuminated region is covered during measurement, and keep the same orientation for blank and sample runs. If your method uses side optical access or the secondary path, repeatable seating helps keep the same sample geometry from run to run.
The 1.75 mL figure is the nominal capacity of the cell, not a minimum working volume. If your instrument uses a fixed beam height or a small beam footprint, confirm the practical fill level in the actual holder before routine use.
First-use check
- Inspect the optical faces, chamber and closure seating area before first use.
- Place the empty cell in the holder to confirm body fit and top clearance.
- Run a blank in the intended orientation and verify that the beam crosses the intended sample region.
- Confirm that the fill level covers the illuminated area without bubbles or residue on the optical faces.
Fit and optical alignment
The stated external dimensions, 12.5 × 12.5 × 45 mm, apply to the uncapped cell body. Use those body dimensions to check holder fit and insertion clearance, and leave extra room above the cell because the installed height with the closure is not established here.
Z Height is not available for this SKU. If your fluorescence holder or optical bench depends on a defined beam-centre height, check that point in your own setup rather than assuming fit from the external body size alone.
Solvents and cleaning
This cuvette uses Standard 80 adhesive-bonded quartz construction. This MQ fabrication option is generally used for room-temperature water-based samples and buffers, and it should be selected with the full sample and cleaning routine in mind.
For this exact option, the supplier excludes acid, alkali and organic-solvent use, and also prohibits ethanol soaking or rinsing. Do not use hydrofluoric acid with quartz, avoid hot strong alkalis and abrasive cleaning, and wipe the exterior optical faces gently with non-abrasive optical tissue.
Included with this option
1 quartz micro cuvette with lid.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We coordinate custom JGS1 quartz versions for changes to dimensions, optical path length, sample volume, optical windows, Z Height, closures and fabrication requirements. If your method needs different chemical resistance or a different geometry, send a drawing or labelled sketch together with holder details, sample conditions and target quantity for review. Discuss your requirements and mention part number C104CS50.
Additional information
| Weight | 30 g |
|---|
You must be logged in to post a review.






Reviews
There are no reviews yet.