(C104TS15) Quartz Micro Cuvette, 10 mm / 2 mm (dual path) Path, 700 µL, Pack of 2
Original price was: $949.00.$855.00Current price is: $855.00.
C104TS15 is a JGS1 quartz micro cuvette for fluorescence spectroscopy, combining a 10 mm main path with a 2 mm secondary path in a Four-Way Light layout. Its 700 µL nominal capacity and compact 12.5 × 12.5 mm base suit methods that need side optical access in a small covered cell. Supplied as a pack of 2 cuvettes, with closures included.
Description
C104TS15 is a JGS1 quartz micro cuvette for fluorescence spectroscopy with a 10 mm / 2 mm dual-path layout in a compact square body. The Four-Way Light configuration gives side optical access for fluorescence setups, while the 700 µL nominal capacity keeps the cell in a small covered format rather than a larger body size. This sales option is supplied as a pack of 2 cuvettes.
- Path Length
- 10 mm / 2 mm (dual path)
- Sample Volume (Nominal)
- 700 µL
- Closure Type
- Screw Cap
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Micro Cuvette |
| Measurement Mode | Fluorescence Spectroscopy |
| Pack Quantity | Pack of 2 |
| Path Length | 10 mm / 2 mm (dual path) |
| Light Transmission Configuration | Four-Way Light |
| Optical Window Dimensions | 2 mm |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 700 µL |
| External Dimensions | 12.5 × 12.5 × 56 mm |
| Cell Body Dimensions | 12.5 × 12.5 × 45 mm |
| Uncapped Cell Dimensions | 12.5 × 12.5 × 56 mm |
| Overall Height without Closure | 56 mm |
| External Dimensions Scope | Uncapped Cell |
| Body Height | 45 mm |
| Overall Height with Closure | 60 mm |
| Base Dimensions | 12.5 × 12.5 mm |
| Material | Quartz |
| Material Grade | JGS1 |
| Closure Type | Screw Cap |
| Closure Included | Yes |
| Fabrication Method | Molded 83 |
| Detection Channel Width | 2 mm |
Choose this option
Choose C104TS15 when your method needs both a 10 mm path and a 2 mm secondary path in the same micro cuvette, and when buying two cells in one order suits your routine or parallel work. The covered top is useful for sample handling, and the 12.5 × 12.5 mm base fits setups built around a compact square cuvette footprint.
What makes this option different
- 10 mm / 2 mm dual path: two stated optical directions in one micro cuvette body.
- Four-Way Light configuration: side optical access supports fluorescence measurement geometry that uses multiple faces.
- 700 µL nominal capacity: micro-cuvette volume in a compact covered format.
- Pack of 2 cuvettes: this MQ sales option includes two physical cuvettes per price unit.
Using this cell
Fill the cell so the illuminated sample region is fully covered during measurement. The 700 µL value is the nominal capacity, not a minimum working volume, so set your actual fill level according to your beam position and the way the cell is used in your instrument.
Keep the optical faces clean and free from droplets, fingerprints and dried residue. Use the same seating direction for blank and sample runs, and fit the closure gently after filling.
First-use check
Before first measurement, inspect the optical faces under good light and rinse with a liquid suitable for your method. Check that the cuvette seats squarely in the holder, then run a blank in the same orientation you will use for the sample.
Fit and optical alignment
The square base is 12.5 × 12.5 mm. For holder planning, distinguish between the 45 mm body height, the 56 mm uncapped overall height and the 60 mm overall height with the closure fitted, because the neck and cap can affect vertical clearance even when the main body fits the holder.
Z Height is not specified for this SKU. If your instrument has a fixed beam height or a tight fluorescence collection geometry, check the actual beam position against your holder rather than assuming alignment from the outside height alone.
Solvents and cleaning
This cuvette uses Molded 83 fabrication. This type is commonly chosen for methods involving organic solvents or temperature-related work, but suitability should still be checked for the complete assembled cell, including the closure, under your actual sample and cleaning conditions.
Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaning. For routine care, rinse promptly after use and wipe the exterior optical faces gently with non-abrasive optical tissue or another suitable non-scratching material.
Included with this option
Supplied as 2 micro cuvettes. A closure is included.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We coordinate custom JGS1 quartz production for requirements involving dimensions, optical path length, sample volume, optical windows or Z Height, closures and fabrication details. Send a dimensioned drawing or labelled sketch and identify the dimensions and tolerances that are critical to your application. Prototype batches typically involve 2–4 cells; the final quantity, feasibility, specifications, price and production time are confirmed in the project quotation. Modified designs and prototype batches are quoted separately from the listed SKU. Discuss your requirements and mention part number C104TS15.
Additional information
| Weight | 30 g |
|---|
You must be logged in to post a review.









Reviews
There are no reviews yet.