(C104TF5) Quartz Screw-Top Cuvette, 10 mm Path, 3.5 mL, Pack of 2
Original price was: $466.00.$420.00Current price is: $420.00.
C104TF5 is a quartz screw-top cuvette with a 10 mm optical path, Four-Way Light geometry and 3.5 mL nominal capacity. The capped top and four optical faces suit methods that need a covered sample chamber with side optical access. Supplied as a pack of 2, with screw caps included.
Description
C104TF5 is a quartz screw-top cuvette built around a 10 mm optical path in a full-size square cuvette format. It combines a 3.5 mL nominal capacity with Four-Way Light access and a covered opening, making it useful when you want manual filling, a capped sample chamber and optical access from more than two sides. This option is sold as a pack of 2, with screw caps included.
- Path Length
- 10 mm
- Sample Volume (Nominal)
- 3.5 mL
- Closure Type
- Screw Cap
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Screw-Top Cuvette |
| Measurement Mode | Fluorescence Spectroscopy |
| Pack Quantity | Pack of 2 |
| Path Length | 10 mm |
| Light Transmission Configuration | Four-Way Light |
| Sample Volume (Nominal) | 3.5 mL |
| Cell Body Dimensions | 12.5 × 12.5 × 35 mm |
| Overall Height without Closure | 54 mm |
| Body Height | 35 mm |
| Overall Height with Closure | 58 mm |
| Base Dimensions | 12.5 × 12.5 mm |
| Material | Quartz |
| Closure Type | Screw Cap |
| Closure Included | Yes |
| Fabrication Method | Molded 0.01 |
Choose this option
Choose C104TF5 when your method uses a 10 mm path and you want a covered quartz cell with optical access on all four sides of the sample region. The 3.5 mL nominal capacity gives a larger sample chamber than compact micro cells, while the square 12.5 × 12.5 mm base keeps the familiar cuvette footprint used in many holders.
What makes this option different
- 10 mm optical path for methods that specify this path length.
- Four-Way Light configuration for optical access from all four vertical faces.
- Screw-top format with cap included for a covered sample chamber after filling.
- Pack of 2 for buyers who need two physical cuvettes in the priced sale unit.
Using this cell
Fill the cuvette through the threaded opening, then seat the cap gently before measurement. Use enough sample to cover the beam path used by your instrument, and clear any bubbles from the optical region before running a blank or sample.
Keep the same orientation for repeat measurements when your method depends on consistent positioning. Handle the cell by the non-optical surfaces where possible to reduce fingerprints on the optical faces. The stated 3.5 mL is nominal capacity, not a minimum working volume.
First-use check
- Inspect the optical faces, base and threaded opening for dust, chips or visible residue.
- Rinse with a cleaning liquid suitable for your method and the full assembled cell.
- Test fit the cuvette and confirm that the fitted cap clears the space above it.
- Run your blank in the same orientation planned for sample measurements.
Fit and optical alignment
The cuvette body is 12.5 × 12.5 × 35 mm with a 12.5 × 12.5 mm base. Stated overall height is 54 mm without the cap and 58 mm with the cap fitted, which is the key clearance check if your holder, compartment lid or cover sits close above the cell.
Z Height is not established for this SKU. If your instrument requires a defined beam-center height, check that point against your holder before ordering rather than assuming instrument-specific alignment from the general body format.
Solvents and cleaning
For a method with a defined optical path tolerance, specify that tolerance and its measurement conditions when selecting the Molded 0.01 option. The final requirement is agreed for the order.
This cuvette is listed under Molded 0.01. This fabrication category is used for quartz cuvettes selected for tighter path-length requirements, but chemical limits for this exact assembled SKU are not established here, so compatibility should be checked for the complete cell and closure when your process involves aggressive chemicals or heated cleaning.
Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaning materials, and wipe the optical faces gently with non-abrasive optical tissue.
Included with this option
Price is for 2 cuvettes. A screw cap is included with this cuvette format.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We also review custom JGS1 quartz cuvette requests involving dimensions, optical path length, sample volume, optical windows or Z Height, closures and fabrication requirements. Send a labelled drawing or sketch, your holder or instrument details, sample conditions and target quantity via our contact page, and refer to part number C104TF5.
Additional information
| Weight | 30 g |
|---|
You must be logged in to post a review.







Reviews
There are no reviews yet.