(C102CF2) Quartz Standard Cuvette, 10 mm Path, 3.5 mL
Original price was: $247.00.$223.00Current price is: $223.00.
C102CF2 is a JGS1 quartz standard cuvette for UV/Vis work with a 10 mm optical path, 3.5 mL nominal capacity and a lid. Its standard rectangular body suits routine liquid measurements where you need direct top access for filling and cleaning, while the stated 190–2500 nm range supports UV/Vis methods using quartz cells.
Description
C102CF2 is a JGS1 quartz standard cuvette for UV/Vis measurements with a 10 mm optical path and 3.5 mL nominal capacity. It combines a familiar rectangular cell body with a lid over the top opening, so you can fill and inspect the sample directly before measurement while still covering the opening during routine handling.
This option is useful when your method is written around a 10 mm path and your sample volume suits a full-size standard cell rather than a micro-format chamber. The stated 190–2500 nm range and quartz body make it suitable for UV/Vis work that requires quartz rather than glass.
- Path Length
- 10 mm
- Sample Volume (Nominal)
- 3.5 mL
- Closure Type
- Lid
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Standard Cuvette |
| Measurement Mode | UV/Vis Spectroscopy |
| Path Length | 10 mm |
| Light Transmission Configuration | Two-Way Light |
| Wavelength Range — Lower Limit | 190 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 3.5 mL |
| External Dimensions | 12.5 × 12.5 × 45 mm |
| Uncapped Cell Dimensions | 12.5 × 12.5 × 45 mm |
| External Dimensions Scope | Uncapped Cell |
| Material | Quartz |
| Material Grade | JGS1 |
| Closure Type | Lid |
| Closure Included | Yes |
| Fabrication Method | Molded 0.01 |
Choose this option
Choose C102CF2 when you need a quartz standard cuvette with direct top filling, a 10 mm optical path and a full-size sample chamber. The 3.5 mL nominal capacity fits routine liquid measurements, and the lid helps cover the opening between preparation and reading without turning the cell into a sealed or pressure-rated assembly.
What makes this option different
- 10 mm optical path for methods specified around this standard transmission length.
- JGS1 quartz body with a stated 190–2500 nm range for UV/Vis applications that need quartz-cell transmission rather than glass.
- 3.5 mL nominal capacity in a standard rectangular cell format for general liquid sampling.
- Lid over the top opening, allowing direct filling and visual checking of the sample before measurement.
- Molded 0.01 fabrication for customers selecting this build style for work that places more attention on path-length control in a quartz cuvette format.
- Listed body dimensions apply to the uncapped cell, which is important when checking holder seating and clearance above the opening.
Using this cell
Fill the cuvette from the top opening and make sure the liquid fully covers the beam area used by your instrument. Remove visible bubbles before measurement, and keep the cell orientation consistent between blank and sample if your procedure depends on repeatable positioning.
The lid is useful as a cover during routine handling and measurement setup, but it should be treated as a cover rather than a leak-proof, pressure-rated or transport seal. Hold the cuvette by the non-optical surfaces to reduce fingerprints on the clear faces.
First-use check
Inspect the optical faces and inner chamber before first use. Rinse with a cleaning liquid suitable for your method, check for residue or handling marks, and run a blank in the same orientation you plan to use for sample measurements.
Fit and optical alignment
The uncapped cell body measures 12.5 × 12.5 × 45 mm. Use those dimensions to check holder seating and to confirm that you have enough clearance above the cell for filling, lid placement and removal.
Z Height is not stated for this option. If your instrument or holder depends on a fixed beam center height, confirm alignment from your fixture requirements rather than assuming fit from the outer body size alone.
Solvents and cleaning
Molded 0.01 is the option to consider when your method calls for closely specified optical-path precision. For the 10 mm path on this cell, agree the required tolerance and measurement conditions for the order.
For customer selection, that makes most sense when you are choosing among quartz cuvette build styles for work where the optical path specification matters and you want to keep your cleaning method controlled and consistent with the cell assembly.
Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaning, and wipe the optical faces gently with non-abrasive optical tissue. Chemical compatibility for the complete cell-and-lid assembly is not fully established here, so if your samples or cleaning steps involve aggressive solvents, high-pH solutions or long contact times, please check suitability before ordering.
Included with this option
A lid is included with this option. The priced sale quantity and any additional package contents are not stated here, so please confirm the sale unit if you need a specific ordering quantity.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We coordinate custom JGS1 quartz production for requirements involving dimensions, optical path length, sample volume, optical windows or Z Height, closures and fabrication details. Send a dimensioned drawing or labelled sketch, together with your holder or instrument information, critical dimensions, sample conditions and target quantity. Discuss your requirements and quote part number C102CF2.
Additional information
| Weight | 30 g |
|---|
You must be logged in to post a review.








Reviews
There are no reviews yet.