(C104SR29) Quartz Micro Cuvette, 10 mm Path, 1.05 mL
Original price was: $293.00.$264.00Current price is: $264.00.
C104SR29 is a quartz micro cuvette for fluorescence spectroscopy with a 10 mm optical path, Four-Way Light access and a 1.05 mL nominal capacity. Its 3 mm sample-region width provides a broader measurement zone than the narrower slit versions, and the stoppered opening lets you cover the sample during handling and measurement. Sold as 1 cuvette per price unit, with stopper included.
Description
C104SR29 is a quartz micro cuvette for fluorescence spectroscopy with a 10 mm optical path, Four-Way Light configuration and 1.05 mL nominal capacity. Its 3 mm sample-region width gives a broader sample zone than the narrow-slit versions in the same style, and the stoppered opening is useful when you want the sample covered during filling, setup and measurement.
- Path Length
- 10 mm
- Sample Volume (Nominal)
- 1.05 mL
- Closure Type
- Stopper
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Micro Cuvette |
| Measurement Mode | Fluorescence Spectroscopy |
| Path Length | 10 mm |
| Light Transmission Configuration | Four-Way Light |
| Optical Window Dimensions | 3 mm |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 1.05 mL |
| Material | Quartz |
| Closure Type | Stopper |
| Closure Included | Yes |
| Detection Channel Width | 3 mm |
Choose this option
Choose C104SR29 when you want a 10 mm path micro cuvette with four-side optical access and a wider sample region than the 1 mm type. The 3 mm sample region and 1.05 mL nominal capacity make it a practical choice for fluorescence work that needs a defined but less narrow measurement zone, while still using a covered stoppered opening.
What makes this option different
- 10 mm optical path suits methods designed around that standard path length.
- Four-Way Light configuration provides optical access from multiple sides for fluorescence setups with suitable beam geometry.
- 3 mm sample-region width gives a broader illuminated sample zone than the narrower slit versions of this cuvette style.
- 1.05 mL nominal capacity offers a larger nominal fill than the smaller-volume versions while keeping the same 10 mm path concept.
- Stopper closure lets you cover the opening during sample handling and measurement.
- Quartz body supports the stated 200–2500 nm wavelength range for this listing.
Using this cell
Fill the cuvette so the measurement region is fully covered at the beam position, and keep the same orientation for blank and sample. The 3 mm sample region gives you a defined illuminated zone, so consistent seating and clean optical faces help keep measurements comparable.
Insert the stopper gently after filling when you want the sample covered during routine handling or measurement. This page does not establish a pressure limit, leak-tight performance or closed-loop fluid use.
First-use check
- Inspect the optical faces, opening and stopper seating area for chips, dust or residue.
- Rinse with a method-suitable liquid before first measurement.
- Test the cuvette in your holder and verify beam alignment with a blank.
- Insert the stopper gently and check that it seats cleanly before running samples.
Fit and optical alignment
The 10 mm path length and 3 mm sample-region width should suit the beam geometry used by your method. Four-Way Light describes the available optical access pattern, but it does not by itself establish compatibility with every fluorescence instrument or holder arrangement.
Z Height is not established for this SKU. If your instrument has a fixed beam center or limited holder adjustment, confirm the required beam height and seating geometry before ordering.
The 1.05 mL figure is a nominal capacity, not a minimum working volume. Set the actual fill level so the beam passes through liquid cleanly and without bubbles.
Solvents and cleaning
This cuvette uses a fused integrated construction as described by the source. For selection purposes, that construction style is commonly chosen for quartz cells used in solvent-based methods, but the exact chemical limits of this assembled SKU are not established on this listing.
Review your sample and cleaning liquids against the full cell assembly before routine use. See Compare fabrication options for general construction guidance. Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaning, and wipe the exterior optical faces with non-abrasive optical tissue.
Included with this option
1 cuvette per listed price unit. Stopper included.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We coordinate custom JGS1 quartz production for requirements involving optical path length, sample volume, optical windows, closures, beam-height constraints and other geometry details. Send a drawing or labelled sketch together with your holder or instrument information, sample conditions and target quantity. Discuss your requirements and quote part number C104SR29.
Additional information
| Weight | 30 g |
|---|