Quartz 10mm Ultra-Micro Cuvette, 50 µl, Standard 80, Two-Way Light, PTFE Cap, 1pc/ea, C102CE26
Description
The C102CE26 is a precision quartz ultra-micro cuvette with 10 mm path length and two-way light optical windows, designed for UV-Vis spectrophotometry (190–2500 nm). The two-way light configuration transmits the beam through two opposing polished optical faces, delivering clean baseline performance for absorbance measurements. A raised quartz platform inside the cuvette body elevates just 50 µl of sample to the beam center at Z = 8.5 mm, saving 99% compared to a standard 3.5 ml cell. Fabricated using Standard 80 (>80% transmittance). Includes a PTFE cap for chemical-resistant sealing.
| Technical Specifications | |||
|---|---|---|---|
| Material | Quartz (Fused Silica) | SKU | C102CE26 |
| Path Length | 10 mm | Minimum Volume | 50 µl |
| Optical Windows | 2 (Two-Way Light) | Z Dimension | 8.5 mm |
| Fabrication | Standard 80 | Transmittance | >80% |
| Wavelength | 190–2500 nm | Exterior Dimensions | 12.5 × 12.5 × 45 mm |
| Cap | PTFE Cap | Package | 1 pc/ea |
Applications
Why Ultra-Micro?
A raised quartz platform elevates 50 µl of sample precisely into the spectrophotometer beam at Z = 8.5 mm, saving 99% compared to a standard 3.5 ml cell while maintaining the full 10 mm optical path (Beer–Lambert law: A = εlc). This is essential for precious biological samples, limited column fractions, or expensive synthetic compounds. Important: the Z dimension must match your instrument’s beam center height — verify before ordering.
Black-Wall Design Benefits
This cuvette features a black-wall (dark-wall) exterior on the two non-optical faces. The opaque coating absorbs stray ambient light and eliminates fluorescence interference from scattered excitation photons bouncing off internal walls. Benefits include: reduced stray-light artifacts at low absorbance readings, improved signal-to-noise in fluorescence measurements, cleaner baselines in the deep-UV region (<230 nm) where scattered light is most problematic, and sharper spectral resolution in high-sensitivity absorbance work. If your application does not require lateral light transmission (excitation/emission at 90°), the black-wall two-way configuration delivers measurably better optical performance than an all-clear four-way cuvette.
Why Standard 80 Construction?
Standard 80 is the premium fabrication method: the cuvette is integrally fused as a single piece with no adhesive or joints. This eliminates solvent attack points and enables operation up to 1200 °C — far exceeding sintered (600 °C) or glue-assembled (200 °C) alternatives. The one-piece construction delivers a path length variation of just ±0.02 mm, ensuring the highest level of reproducibility. With transmittance >80%, Standard 80 is the gold standard for demanding research applications.
Additional information
| Weight | 30 g |
|---|