(C012WS) Quartz Rectangular Sample Cell, 1 mm Path, 350 µL
Original price was: $380.00.$342.00Current price is: $342.00.
C012WS is a JGS1 quartz rectangular sample cell with a 1 mm optical path, Two-Way Light geometry and a single open neck for direct top filling. Its 350 µL nominal volume and slim 12.5 × 3.5 mm body section suit UV/Vis work where a short path and a narrow seated footprint are more important than a standard-width cuvette body. Sold as 1 cuvette per price unit.
Description
C012WS is a JGS1 quartz rectangular sample cell for UV/Vis spectroscopy across the stated 200–2500 nm range. It combines a 1 mm optical path with Two-Way Light transmission and a single open neck, giving direct access to the sample chamber from above. The 350 µL nominal volume and slim body section make it a practical choice when you need a short path length in a narrow rectangular format rather than a broader standard body.
- Path Length
- 1 mm
- Sample Volume (Nominal)
- 350 µL
- Opening Configuration
- Single Open Neck
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Rectangular Sample Cell |
| Measurement Mode | UV/Vis Spectroscopy |
| Path Length | 1 mm |
| Light Transmission Configuration | Two-Way Light |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 350 µL |
| Body Height | 45 mm |
| Base Dimensions | 12.5 × 3.5 mm |
| Material | Quartz |
| Material Grade | JGS1 |
| Port Count | 1 |
| Tube Outer Diameter (OD) | 6.35 mm |
| Fabrication Method | Molded 83 |
| Opening Configuration | Single Open Neck |
Choose this option
Choose C012WS when your method needs a 1 mm transmission path in a quartz cell that fills from the top through one necked opening. This layout is useful when you want straightforward sample introduction and a compact seated section in the holder area. Its Molded 83 construction also makes it a suitable option for methods that may involve organic-solvent handling, while still requiring normal quartz care limits.
What makes this option different
- 1 mm optical path: suited to methods that call for a short transmission distance through the sample.
- Single open neck: sample access is from the top through one neck rather than through a wide open chamber.
- 350 µL nominal volume: useful for small sample charges in a compact rectangular chamber.
- Slim 12.5 × 3.5 mm seated body section: helpful when holder width and side clearance matter.
Using this cell
Fill the cell through the open neck and make sure the sample fully covers the optical path during measurement. For short-path work, bubbles, streaks and droplets on the light path can affect the reading more quickly than in a larger chamber, so inspect the filled sample region before placing the cell in the instrument.
Use a consistent orientation for blank and sample measurements. Handle the cell by non-optical surfaces, and keep fingerprints away from the optical faces.
First-use check
- Inspect the optical faces and neck opening for chips, residue or packing debris.
- Test the empty cell in your holder to confirm seating and top clearance.
- After rinsing, fill the cell and check that the beam area is fully covered and free of bubbles.
Fit and optical alignment
The body height is 45 mm, and the illustrated overall height including the neck section is 95 mm. The seated rectangular body section is 12.5 × 3.5 mm, which is the most useful dimension here for holder fit and side clearance around the cell body.
The neck outer diameter is 6.35 mm, which can help when planning top-side clearance near sleeves, clips or nearby tubing hardware. Z Height is not established for this cell, so if your instrument depends on a fixed beam-center height, check holder geometry before ordering. The single neck provides sample access, but it should not be treated as a confirmed flow-through or pressure-rated connection.
Solvents and cleaning
Molded 83 quartz cells are commonly chosen for methods involving organic solvents and applications with temperature-related handling requirements. Select the actual sample and cleaning routine for the complete cell and your working conditions.
Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaning methods. Clean the optical faces gently with suitable non-abrasive lab wipes or optical tissue.
Included with this option
1 cuvette per listed price unit. If you need a supplied closure or other accessory, contact us before ordering.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We coordinate custom JGS1 quartz production for requirements involving dimensions, optical path length, sample volume, optical windows or Z Height, closures and connections, fabrication and tolerances. Send a dimensioned drawing or labelled sketch and identify the dimensions and tolerances that matter to your application. Prototype batches typically involve 2–4 cells; final feasibility, quantity, price and production time are confirmed in the quotation. Discuss your requirements and quote part number C012WS.
Additional information
| Weight | 30 g |
|---|
You must be logged in to post a review.







Reviews
There are no reviews yet.