(C024TS6) Quartz Screw-Top Cuvette, 2 mm Path, 700 µL, Pack of 2
Original price was: $569.00.$513.00Current price is: $513.00.
C024TS6 is a JGS1 quartz screw-top cuvette for fluorescence spectroscopy with a 2 mm optical path, Four-Way Light geometry and 700 µL nominal capacity. The threaded opening and included closure suit covered sample handling in a compact four-side optical format. Supplied as a pack of 2 cuvettes.
Description
C024TS6 is a JGS1 quartz screw-top cuvette for fluorescence spectroscopy with a 2 mm optical path and a 700 µL nominal capacity. Its Four-Way Light geometry gives optical access from multiple side directions, while the threaded opening and included closure make it useful when you want a covered sample cell instead of an open-top chamber. This sales option is supplied as a pack of 2 cuvettes.
- Path Length
- 2 mm
- Sample Volume (Nominal)
- 700 µL
- Opening Configuration
- Threaded Opening
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Screw-Top Cuvette |
| Measurement Mode | Fluorescence Spectroscopy |
| Pack Quantity | Pack of 2 |
| Path Length | 2 mm |
| Light Transmission Configuration | Four-Way Light |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 700 µL |
| Body Height | 35 mm |
| Base Dimensions | 12.5 × 4.5 mm |
| Material | Quartz |
| Material Grade | JGS1 |
| Closure Type | Screw Cap |
| Closure Included | Yes |
| Opening Configuration | Threaded Opening |
Choose this option
Choose C024TS6 when your fluorescence setup uses a 2 mm path and benefits from side optical access around the sample region. The combination of Four-Way Light geometry, JGS1 quartz and a screw-top opening suits workflows where you want a compact capped cell for filling, transfer and measurement, while the pack-of-two sale unit is practical for duplicate work, blank-and-sample use or keeping a spare in the same format.
What makes this option different
- 2 mm optical path for methods built around this shorter path length.
- Four-Way Light geometry for optical access from multiple side orientations around the cell.
- JGS1 quartz body specified here for fluorescence use over a 200–2500 nm stated range.
- Threaded opening with closure included for covered sample handling.
- Pack of 2 cuvettes for paired routine use in the same format.
Using this cell
Fill the cell so the liquid fully covers the optical region used by your setup, then close the threaded top carefully. Before measurement, remove visible bubbles and keep the same orientation when your fluorescence method depends on repeatable positioning.
Handle the cuvette by the non-optical surfaces to keep the optical faces clean. The screw-top format is useful for routine handling of filled samples, but no pressure rating is stated for this item, so it should not be selected for pressure service or assumed leak-tight transport under demanding conditions.
First-use check
- Inspect the optical faces, threaded opening and cap for chips, residue or shipping damage.
- Rinse with a cleaning liquid suitable for your method before first use.
- Place the cell in your holder and confirm stable seating and cap clearance.
- Run a blank or reference in the same orientation planned for the sample.
Fit and optical alignment
The optical body footprint is listed as 12.5 × 4.5 mm, and the body height is 35 mm. These figures are useful for checking holder support and body clearance, especially in compact fluorescence compartments.
Z Height is not stated for this SKU, and the full capped envelope is not listed here. If your holder or instrument depends on a defined beam-center height or tight clearance around the cap area, those points should be checked before ordering.
Solvents and cleaning
JGS1 quartz is specified for this SKU, but the chemical limits of the complete assembly are not stated here. If your method uses aggressive chemicals, elevated temperatures or long contact times, review the full sample and cleaning conditions for the assembled cell rather than relying on the quartz body alone.
For general background, see the fabrication overview. Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaning, and wipe the optical faces gently with non-abrasive optical tissue.
Included with this option
Supplied as 2 screw-top cuvettes. A closure is included with this option. The exact package contents beyond the included closure are not separately specified here.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
If you need a related quartz cuvette with different dimensions, path length, sample volume, optical access or closure details, send a dimensioned drawing or labelled sketch together with your instrument or holder information. Discuss your requirements and quote part number C024TS6.
Additional information
| Weight | 30 g |
|---|
You must be logged in to post a review.