Quartz 30mm micro-volume flow cuvette, 96 ul, two-way light windows, 12.5 × 32.5 × 35 mm. Standard 80 fabrication, 190-2500 nm, SKU: C302WS1 Z dimension: 8.5 mm.

In Stock
Add to Wishlist
Add to Wishlist
SKU: C302WS1 Categories: , ,

Description

The C302WS1 is a quartz micro-volume flow cuvette with 30 mm path length and two-way light windows (two polished optical faces for standard UV-Vis absorbance geometry), holding 96 ul of sample. The cell measures 12.5 × 32.5 × 35 mm externally with an internal chamber of 10 × 30 × 32 mm. Inlet and outlet ports enable continuous sample flow for real-time monitoring applications. Fabricated using Standard 80 technique with precision-glued quartz construction, delivering >80% transmittance across the 190-2500 nm range. The quartz body is suitable for aqueous (water-based) solutions only. Do not use with organic solvents, strong acids, or strong bases. The Z dimension (beam center height) is 8.5 mm from the cell bottom — verify compatibility with your instrument’s beam height before ordering.

Technical Specifications
Material Quartz (Fused Silica) SKU C302WS1
Type Micro-Volume Flow Cuvette Path Length 30 mm
Volume 96 ul Optical Windows Two-Way Light (2)
Fabrication Standard 80 Transmittance >80%
Wavelength Range 190-2500 nm Exterior Dimensions 12.5 × 32.5 × 35 mm
Interior Dimensions 10 × 30 × 32 mm Z Dimension 8.5 mm
Cap / Closure None (Flow Cell) Package 1pc/ea

Applications

◆ Ultra-small-volume UV-Vis spectroscopy
◆ Precious & limited sample analysis
◆ Micro-flow injection analysis (µFIA)
◆ On-chip spectroscopic detection
◆ Single-drop & capillary analysis
◆ Pharmaceutical micro-dose quantification
◆ Microfluidics & lab-on-chip coupling
◆ High-throughput screening of rare compounds

Why Two-Way Light Windows?

The two-way configuration provides two optically polished opposing faces for standard transmission-mode spectroscopy (UV-Vis, NIR). The remaining two walls are frosted (ground) to suppress internal reflections and stray light, improving baseline stability and measurement reproducibility. This is the most common geometry for absorbance-based flow analysis — compatible with virtually every single-beam and double-beam spectrophotometer on the market.

Why a Flow Cell?

Flow cells enable continuous, real-time spectroscopic monitoring without manual sample handling. Micro-volume flow cells minimize sample consumption while maintaining full optical-path performance. The reduced chamber volume allows faster sample turnover, sharper concentration transitions, and lower dead volume — critical for precious samples, micro-flow injection analysis, and coupling with micro-bore chromatography systems.

Why Standard 80 Fabrication?

The Standard 80 fabrication creates a monolithic fused-quartz cell from a single block — no adhesive joints, no bonding layers. This delivers >80% transmittance and complete resistance to all common laboratory solvents, concentrated acids, and bases (avoid HF). The seamless construction eliminates leakage risks and withstands repeated thermal cycling, making Standard 80 the premium choice for demanding flow applications.

Usage Tips: The micro-volume design requires careful priming to eliminate air bubbles from the optical path. Use a syringe or low-pulsation pump to fill the cell slowly. Ensure all tubing connections are secure before starting flow. The small chamber volume means fast response time but also higher sensitivity to blockages — pre-filter samples if particulates are present. Clean with spectroscopic-grade solvent between sample types. The 30 mm path length follows Beer-Lambert law: A = εlc.
Custom Orders & Academic Purchasing: Need a custom path length, tube diameter, volume, or window configuration? We manufacture made-to-order flow cells tailored to your exact specifications. Academic institutions: we accept Purchase Orders (POs) with pay-after-delivery terms. Request a custom quote.
Disclaimer: Specifications are nominal values measured under standard laboratory conditions. Actual transmittance may vary slightly with wavelength and sample composition. Images are representative; minor cosmetic variations between production batches are normal and do not affect optical performance. For critical applications, request a Certificate of Analysis at time of order.

Additional information

Weight 30 g

Reviews

There are no reviews yet.

Be the first to review “Quartz 30mm, Two-Way Light, Micro Flow Cuvette, 96 ul, Standard 80, C302WS1”

You may also like…

Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • SKU
  • Rating
  • Price
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Weight
  • Dimensions
  • Additional information
  • Attributes
  • Custom attributes
  • Custom fields
Click outside to hide the compare bar
Compare