(C302CA2) Quartz Large-Window Cuvette
Original price was: $80.00.$72.00Current price is: $72.00.
C302CA2 is a JGS1 quartz large-window cuvette for UV/Vis work, with an open top for direct filling and an included PTFE closure. Its 12.5 × 32.5 × 45 mm body gives a broader optical face than a narrow square cell. This listing covers the selected cuvette option with PTFE closure included.
Description
C302CA2 is a JGS1 quartz large-window cuvette for UV/Vis spectroscopy. Its broad-face body and open-top format make it easier to fill, rinse and inspect than a narrower rectangular cell, and the included PTFE closure supports covered handling after loading. This option is best selected when the body shape and holder clearance matter as much as the optical material.
- Sample Volume (Nominal)
- 10.5 mL
- Opening Configuration
- Open Top
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Large-Window Cuvette |
| Measurement Mode | UV/Vis Spectroscopy |
| Sample Volume (Nominal) | 10.5 mL |
| Cell Body Dimensions | 12.5 × 32.5 × 45 mm |
| Body Height | 45 mm |
| Base Dimensions | 12.5 × 32.5 mm |
| Material | Quartz |
| Material Grade | JGS1 |
| Closure Type | Lid |
| Closure Material | PTFE |
| Closure Included | Yes |
| Opening Configuration | Open Top |
Choose this option
Choose C302CA2 when you need a large-window cuvette body with direct top access rather than a narrow standard-format cell. The 12.5 × 32.5 mm base and 45 mm body height are the key fit points for holder seating and vertical clearance, while the JGS1 quartz body suits UV/Vis use. Because the beam-center height is not established here, this option is most practical when you can verify beam position in your own holder.
What makes this option different
- Large-window body with a broader optical face than a narrow square cuvette.
- Open-top access for direct filling, emptying and visual inspection.
- JGS1 quartz body for UV/Vis spectroscopy.
- PTFE closure included for the selected cuvette option.
- 12.5 × 32.5 × 45 mm body size for holder and chamber-clearance checks.
Using this cell
Fill the cell from the open top and make sure the sample covers the illuminated region used by your instrument. For repeatable work, keep the same orientation for blank and sample measurements and avoid touching the optical faces during handling.
If you use the included PTFE closure during measurement or between bench steps, seat it consistently and check that it suits your handling routine. This page does not establish a pressure rating, so the cuvette should be chosen as an open-top laboratory cell rather than as a pressurised assembly.
First-use check
- Inspect the optical faces and top opening for dust, residue or edge damage.
- Place the cuvette in your holder and check that it seats securely without side interference.
- Run a blank to verify that the beam passes through the intended sample region.
- Check the PTFE closure fit if you plan to use it during handling or measurement.
Fit and optical alignment
The body measures 12.5 × 32.5 × 45 mm, with a 12.5 × 32.5 mm base. That broader body can affect holder fit, side clearance and the way the optical faces line up in instruments designed around narrower cuvettes.
Z Height is not established for this exact option. If your instrument uses a fixed beam position or a tight holder, check both the mechanical fit and the beam-height requirement before ordering.
Solvents and cleaning
This quartz cuvette is presented for UV/Vis use, and the source describes qualitative resistance to acids, alkalis and organic liquids. Treat that as a general material-direction statement, not as a complete compatibility list for every chemical, concentration, temperature, exposure time or wetted component in your setup.
Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaning. Wipe the exterior optical faces gently with non-abrasive optical tissue. For fabrication-related background, see MQ Cuvette Fabrication Glossary.
Included with this option
This listing is for the selected C302CA2 cuvette option with an included PTFE closure. Supplied quantities for any additional package items are confirmed with the order.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We coordinate custom JGS1 quartz production for changes involving dimensions, optical path length, sample volume, optical windows or Z Height, closures and connections, fabrication and tolerances. Send a dimensioned drawing or labelled sketch together with your holder or instrument details, critical dimensions, sample conditions and target quantity. Prototype batches typically involve 2–4 cells; feasibility, final specifications, price and production time are confirmed in the project quotation. Discuss your requirements and mention part number C302CA2.
Additional information
| Weight | 100 g |
|---|
You must be logged in to post a review.