(C504CA2) Quartz Fluorescence Cuvette, 50 mm / 10 mm (dual path) Path, 17.5 mL
Original price was: $237.00.$214.00Current price is: $214.00.
C504CA2 is a JGS1 quartz fluorescence cuvette with a 50 mm primary path, a 10 mm secondary path and 17.5 mL nominal capacity for long-path fluorescence measurements. A PTFE closure is included, and this listing is sold as 1 cuvette.
Description
C504CA2 is a JGS1 quartz fluorescence cuvette for fluorescence spectroscopy setups that use a long 50 mm optical path. It combines a 50 mm primary path, a 10 mm secondary path and a 17.5 mL nominal capacity in a larger cuvette body, which is useful when your method is built around longer path geometry rather than a standard square fluorescence cell. A PTFE closure is included with this sale unit.
- Path Length
- 50 mm / 10 mm (dual path)
- Sample Volume (Nominal)
- 17.5 mL
- Closure Type
- Lid
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Fluorescence Cuvette |
| Measurement Mode | Fluorescence Spectroscopy |
| Pack Quantity | 1 Piece |
| Path Length | 50 mm / 10 mm (dual path) |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 17.5 mL |
| External Dimensions | 12.5 × 52.5 × 45 mm |
| Uncapped Cell Dimensions | 12.5 × 52.5 × 45 mm |
| External Dimensions Scope | Uncapped Cell |
| Material | Quartz |
| Material Grade | JGS1 |
| Closure Type | Lid |
| Closure Material | PTFE |
| Closure Included | Yes |
Choose this option
Choose C504CA2 when your measurement method specifically calls for a 50 mm fluorescence cuvette and you need the stated 10 mm secondary direction in the same cell. The larger body and 17.5 mL nominal capacity make it a practical choice for methods that work with a deeper filled sample region and need long-path geometry without moving to a flow-cell format.
What makes this option different
- 50 mm primary path: suited to fluorescence work built around a long optical path.
- 10 mm secondary path: provides a second stated optical direction in the same cell body.
- 17.5 mL nominal capacity: useful for methods that use a larger filled cuvette than a routine 10 mm body.
- PTFE closure included: supplied with a fitted closure rather than as an open cell only.
Using this cell
Fill the cell according to your method and keep the outer optical faces clean and dry. Before measurement, check that the beam area is free of bubbles, droplets and residue, especially if your procedure depends on stable alignment through the 50 mm direction.
If your workflow uses both stated path directions, keep the cell orientation consistent between blank and sample measurements. Marking the measurement direction before routine use can help avoid rotating the cell into a different optical position partway through a run.
First-use check
Inspect the optical faces for chips, transit marks or residue, then rinse the cell using a cleaning routine suitable for your application. Test fit the empty cell in the holder first, and confirm the orientation you will use before introducing sample.
Fit and optical alignment
The stated external dimensions apply to the uncapped cell: 12.5 × 52.5 × 45 mm. Use those dimensions to check holder space and compartment clearance, especially at the wider 52.5 mm side, and allow extra room above the holder position for the installed closure.
Z Height is not stated for this option. If your holder or instrument depends on a defined beam-center height, check that requirement before ordering rather than relying on the outer body dimensions alone.
Solvents and cleaning
Quartz is widely used for laboratory optical work, but the specific chemical limits for this exact cell and closure combination are not stated here. Choose sample and cleaning conditions for the complete assembly, not for the quartz body alone.
Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaning, and wipe the exterior optical faces gently with non-abrasive optical tissue. For general fabrication background across MQ cuvette ranges, see Compare fabrication methods.
Included with this option
Supplied as 1 fluorescence cuvette with a PTFE closure included.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We coordinate custom JGS1 quartz production for related requirements involving dimensions, optical path length, sample volume, optical windows or Z Height, closures and tolerances. Send a dimensioned drawing or labelled sketch, your holder or instrument details, sample conditions and target quantity via https://machinedquartz.com/contact/, and quote part number C504CA2.
Additional information
| Weight | 100 g |
|---|
You must be logged in to post a review.






Reviews
There are no reviews yet.