(C502SS) Quartz Stoppered Cuvette, 50 mm Path, 17.5 mL
Original price was: $252.00.$227.00Current price is: $227.00.
C502SS is a JGS1 quartz stoppered cuvette with a 50 mm optical path, Two-Way Light geometry and 17.5 mL nominal capacity. This long-path covered format suits transmission methods that need a defined 50 mm beam path together with a filled sample region that remains covered during handling and measurement. Sold per listed price unit as 1 cuvette, with closure included.
Description
C502SS is a JGS1 quartz stoppered cuvette for transmission measurements using a 50 mm optical path. Its long-path, covered format combines Two-Way Light geometry with a 17.5 mL nominal capacity, making it useful when your method needs a defined straight-through beam path and a larger filled sample region than shorter-path cells. The listed price unit is 1 cuvette, and the supplier describes the cell as supplied with a closure and box.
- Path Length
- 50 mm
- Sample Volume (Nominal)
- 17.5 mL
- Closure Type
- Stopper
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Stoppered Cuvette |
| Measurement Mode | UV/Vis Spectroscopy |
| Pack Quantity | 1 Piece |
| Path Length | 50 mm |
| Light Transmission Configuration | Two-Way Light |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 17.5 mL |
| External Dimensions | 52.5 × 12.5 × 45 mm |
| Body Height | 45 mm |
| Base Dimensions | 52.5 × 12.5 mm |
| Material | Quartz |
| Material Grade | JGS1 |
| Closure Type | Stopper |
| Closure Included | Yes |
Choose this option
Choose C502SS when your procedure is written for a 50 mm path and you want the sample covered rather than left open at the top. In this exact format, the longer path and 17.5 mL nominal capacity matter together: you are filling a comparatively large sample region so the liquid can cover the optical measurement area used by a long-path transmission method, then closing the cell for handling and measurement.
What makes this option different
- 50 mm optical path suits methods specified for a long transmission distance through the sample.
- Two-Way Light geometry is arranged for straight-through optical access across opposite faces, which is the standard layout to check in transmission holders and beam paths.
- Stoppered format keeps the opening covered after filling, which is useful when you want the sample contained during transfer and measurement.
- 17.5 mL nominal capacity indicates a larger sample region than micro-volume cells, so filling requirements are different from short-path, low-volume formats.
- JGS1 quartz body is specified for the 200–2500 nm range stated for this SKU.
- Fused integrated construction is the supplier’s construction term for this assembled cell, so construction choice should be considered together with your sample and cleaning conditions rather than treated as a separate cap-only detail.
Using this cell
Fill the cell so the liquid fully covers the optical measurement region required by your method, then insert the stopper carefully. Because this is a 50 mm path cell with a 17.5 mL nominal capacity, it is best treated as a long-path filled sample chamber rather than as a low-volume cell; the nominal capacity is a stated total capacity, not a minimum working fill.
Before measurement, remove visible bubbles and keep the same cell orientation for blank and sample. Handle the cuvette by the outer non-optical surfaces where possible to keep the transmission faces clean.
First-use check
Inspect the optical faces for dust, fingerprints or packing residue before first use. Rinse with a suitable liquid for your method, fill the cell in its intended orientation, and confirm that the sample region covers the beam path cleanly without trapped bubbles before taking readings.
Fit and optical alignment
The cuvette body is 52.5 × 12.5 × 45 mm, with the same 52.5 × 12.5 mm base footprint. These dimensions are useful for checking holder seating and general instrument clearance, while the stoppered top means you should also allow enough vertical space to insert and remove the closure comfortably.
Z Height is not specified for this SKU. If your instrument has a fixed beam height or a tightly defined holder position, check the required beam alignment before ordering instead of relying on body height alone.
Solvents and cleaning
This cuvette is described by the supplier as having fused integrated construction. For general construction background, see cuvette fabrication methods, but choose cleaning and sample contact conditions for the full assembled cell, including its covered access arrangement.
The chemical limits of this exact assembled cell are not established here. If your work involves aggressive solvents, elevated temperature or long contact time, check suitability for the complete cell before use.
Do not use hydrofluoric acid with quartz. Avoid hot strong alkalis and abrasive cleaning, and clean the optical faces gently with non-abrasive optical tissue or another suitable laboratory wipe.
Included with this option
1 cuvette per listed price unit. Closure included.
Availability and ordering
Order this listed specification directly, or ask about current availability and dispatch. If your delivery date is important, ask before checkout; preparation or production time is separate from transit and customs clearance.
Discuss a custom version
If you need a different path length, body geometry or other dimensional change, send a drawing or describe the change you need. Custom JGS1 quartz enquiries are handled separately from this listed specification, and feasibility, quantity, price and production time are confirmed in the project quotation.
Additional information
| Weight | 100 g |
|---|---|
| Dimensions | 1.25 × 5.25 × 4.5 mm |
You must be logged in to post a review.






Reviews