(C054WS) Quartz Fluorescence Cuvette, 5 mm Path, 1.75 mL
Original price was: $346.00.$312.00Current price is: $312.00.
C054WS is a JGS1 quartz fluorescence cuvette with a 5 mm optical path, Four-Way Light geometry and a single open neck above the sample chamber. Its 1.75 mL nominal capacity and 8 mm tube OD make it useful when you need top access and optical access from multiple sides. The listed price is for 1 cuvette.
Description
C054WS is a JGS1 quartz fluorescence cuvette for fluorescence spectroscopy, combining a 5 mm optical path with Four-Way Light geometry and a single open neck. Its 1.75 mL nominal capacity, 45 mm body height and narrow 12.5 × 7.5 mm base help when you need a compact cell that still leaves direct access from above for filling and handling.
This version also has an 8 mm tube OD at the top. That upper section matters for practical installation: the base footprint is only part of the space the cell occupies once it is in a holder or fixture.
- Path Length
- 5 mm
- Sample Volume (Nominal)
- 1.75 mL
- Opening Configuration
- Single Open Neck
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Fluorescence Cuvette |
| Measurement Mode | Fluorescence Spectroscopy |
| Path Length | 5 mm |
| Light Transmission Configuration | Four-Way Light |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 1.75 mL |
| Body Height | 45 mm |
| Base Dimensions | 12.5 × 7.5 mm |
| Material | Quartz |
| Material Grade | JGS1 |
| Port Count | 1 |
| Tube Outer Diameter (OD) | 8 mm |
| Fabrication Method | Molded 83 |
| Opening Configuration | Single Open Neck |
Choose this option
Choose C054WS when your fluorescence method uses a 5 mm path and benefits from optical access on four sides, while the sample is introduced from a single top neck. It is a useful format for setups where you need to fill, inspect or empty the cell from above instead of working with a sealed or side-connected design.
What makes this option different
- 5 mm optical path for methods built around this shorter path length.
- Four-Way Light geometry gives optical access from multiple sides of the sample region.
- Single open neck with 8 mm tube OD provides direct top access and affects the clearance needed above the cell.
- Compact 12.5 × 7.5 mm base with 45 mm body height helps when holder space is limited at the seating point.
Using this cell
Fill and empty the cell through the open neck at the top. Keep the optical faces clean and make sure the sample region is free from visible bubbles, droplets and dried residue before measurement.
For fluorescence work, keep the cell orientation consistent between blank and sample measurements so the same optical faces are used each time. The 1.75 mL figure is the nominal capacity of the cell, not a stated minimum working volume, so partial-fill methods should be checked against your own beam position and measurement routine.
First-use check
Before first use, inspect the optical faces and the neck opening for chips, scratches, particles or residue. Rinse with a liquid suitable for your method, seat the cell in the intended holder, and run a blank in the same orientation you will use for the sample.
Fit and optical alignment
The base dimensions are 12.5 × 7.5 mm and the body height is 45 mm, but the neck projects above the body. Plan for insertion, filling and finger clearance around the upper section rather than checking fit from the base footprint alone.
Four-Way Light describes the optical access geometry of the cuvette itself. Z Height is not listed for this option, so do not assume beam-center alignment from the outer height alone if your holder or instrument requires a defined beam position.
Solvents and cleaning
This cuvette uses Molded 83 fabrication in JGS1 quartz. That construction is commonly chosen for methods involving organic solvents, but the chemical limits for this exact assembly are not specified here, so check your sample and cleaning liquids before extended contact or more demanding conditions.
Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaning, and wipe the optical faces gently with non-abrasive optical tissue.
Included with this option
1 cuvette per listed price unit. Please contact us before ordering if you need a supplied closure or other accessory.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.