(MQQMC032) Black-Wall JGS1 Quartz Micro Cuvette, 10 mm Path, 700 µL, Pack of 2
$696.00
Pack of two black-wall JGS1 quartz micro cuvettes with a 10 mm optical path, 2 mm slit and 700 µL nominal capacity per cell. Two opposing optical faces provide transmission access through the narrow sample region. Molded 83 construction, an open top and supplied covers complete this two-cell pack.
Description
MQQMC032 combines the 10 mm transmission path with a narrow 2 mm slit in a black-wall quartz body. Each cell has a 700 µL nominal capacity. The listed price covers two cells with their supplied covers and protective packaging.
- Path Length
- 10 mm
- Sample Volume (Nominal)
- 700 µL
- Opening Configuration
- Open Top
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Micro Cuvette |
| Measurement Mode | UV/Vis Spectroscopy |
| Path Length | 10 mm |
| Light Transmission Configuration | Two-Way Light |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 700 µL |
| External Dimensions | 12.5 × 12.5 × 45 mm |
| Cell Body Dimensions | 12.5 × 12.5 × 45 mm |
| External Dimensions Scope | Body Only |
| Body Height | 45 mm |
| Base Dimensions | 12.5 × 12.5 mm |
| Material | Quartz |
| Material Grade | JGS1 |
| Closure Included | Yes |
| Fabrication Method | Molded 83 |
| Opening Configuration | Open Top |
| Detection Channel Width | 2 mm |
| Sales Unit | pack of 2 |
| Package Contents | 2 × Micro Cuvette; Accompanying closures |
Choose this option
Choose this format when your transmission method needs a 10 mm path and a narrow sample region enclosed by black walls. The 2 mm slit and the beam position are key selection points. For fluorescence methods requiring adjacent optical access, compare a suitable four-face cell. Choose this pack when you need two cells of the same design for routine work or a spare; optical matching is not specified.
What makes this option different
- 10 mm optical path: the transmission distance through the sample is separate from the 2 mm slit width.
- 2 mm slit: the narrow sample region makes beam position and repeatable seating especially important. Check the beam footprint against the actual opening.
- Black-wall, two-face layout: align the intended opposing transmitting faces with the beam. Keep the same measurement direction when moving between the blank and sample.
- 700 µL nominal capacity per cell: this describes each chamber. Establish the working fill required to cover your beam without bubbles.
- Two-cell sales pack: two cells are supplied at the listed price. If your method requires optical matching, include the matching tolerance in your enquiry.
Using this cell
Fill through the open top and remove bubbles before measurement. Keep the slit, transmitting faces and cell orientation consistent between blank and sample. Handle the rim or edges to keep fingerprints away from the optical region. The supplied cover helps protect the opening during handling; sealing performance and pressure capability are not specified.
Nominal capacity is not a minimum working-volume specification. Establish a fill that fully covers the beam at the actual measurement position, then use the same procedure for the blank and sample.
First-use check
- Inspect the rim, body and optical faces for damage, dust or residue.
- Seat the cell in the holder and check beam access with a suitable blank.
- Confirm full beam coverage, clear bubbles and repeatable positioning before measuring the sample.
Fit and optical alignment
The bare body is 12.5 × 12.5 × 45 mm. Use the external dimensions to check holder seating and clearance, allowing additional room for the cover and pipette access. Check the beam against the 2 mm slit separately; a common 10 mm path does not establish instrument compatibility.
Z Height is not specified for this option. Check beam-centre alignment in the actual holder before selecting the working fill.
View the English selection reference.
The gallery shows one individual cell from different angles; the sales quantity for this listing is two cells.

Solvents and cleaning
This cell uses Molded 83 construction. When selecting it for organic-solvent methods or procedures involving heat, review the chemical, concentration, temperature and contact time for the complete cell and cover. The construction designation does not replace application-specific compatibility checks.
Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis, abrasive cleaning and sudden temperature changes. Rinse away sample residue and clean exterior optical faces gently with non-abrasive optical tissue.
Included with this option
Two MQQMC032 black-wall micro cuvettes with supplied covers and protective packaging. The price is per two-cell pack.
Availability and ordering
Contact us to confirm current availability and dispatch timing for your quantity. For a required delivery date, check timing before checkout; preparation and production are separate from carrier transit and customs clearance.
Discuss a custom version
For a different path, sample region, optical layout, body geometry or closure, send a drawing or labelled sketch, holder and beam details, sample conditions and required quantity. Material, construction, feasibility and any prototype batch are confirmed for the quoted project. Contact us and include MQQMC032.