(MQQFL076) Glass Rectangular Sample Cell, 1/25 mm paths, 1.3 mL nominal capacity, V-Shaped End Openings
$96.00
Glass rectangular sample cell for visible spectroscopy and visible-light fluorescence, with 1 mm and 25 mm optical paths, Four-Way Light access and a 1.3 mL nominal capacity. Open V-shaped ends at both sides give direct access for filling and handling, and the listed sale unit is 1 piece.
Description
MQQFL076 is a glass rectangular sample cell for visible-light fluorescence and visible spectroscopy, combining 1 mm and 25 mm optical paths in one body. Its Four-Way Light layout and open V-shaped ends at both sides are useful when you need direct access to the sample and a repeatable optical orientation in a fixture. The nominal capacity is 1.3 mL.
- Path Length
- 1 mm / 25 mm (dual path)
- Sample Volume (Nominal)
- 1.3 mL
- Opening Configuration
- Open at Both Ends
Selection Specifications
| Product Kind | Flow Cell |
|---|---|
| Cell Type | Flow Cell |
| Measurement Mode | Visible-Light Fluorescence; Visible Spectroscopy |
| Path Length | 1 mm / 25 mm (dual path) |
| Light Transmission Configuration | Four-Way Light |
| Wavelength Range — Lower Limit | 350 nm |
| Wavelength Range — Upper Limit | 2000 nm |
| Sample Volume (Nominal) | 1.3 mL |
| External Dimensions | 31 × 11 × 55 mm |
| Cell Body Dimensions | 31 × 11 × 55 mm |
| External Dimensions Scope | Body Only |
| Body Height | 55 mm |
| Material | Glass |
| Fabrication Method | Standard 80 |
| Opening Configuration | Open at Both Ends |
| Pack Quantity | 1 Piece |
| Package Contents | 1 × Glass Rectangular Sample Cell |
Choose this option
Choose MQQFL076 when your method needs two optical directions in the same cell and access from both ends for filling or sample handling. This format is particularly useful when the way you introduce or remove the sample matters as much as the optical path you measure through.
What makes this option different
- 1 mm and 25 mm optical paths in the same cell body for two measurement directions.
- Four-Way Light access for visible-light fluorescence and visible spectroscopy layouts that use side optical access.
- Open at both ends with V-shaped openings for direct filling and sample handling from either side.
- 31 × 11 × 55 mm body dimensions for holder-clearance planning around the cell body.
Structure and dimensions

Using this cell
Use the same optical direction consistently through blank and sample measurements. Fill the cell so the illuminated region is fully covered, and remove visible bubbles before reading.
Because both ends are open, this cell should be used in a suitable holder or fixture that keeps the body seated and oriented repeatably. The open V-shaped ends can be helpful during filling and draining, but they are part of the handling access and should be considered when planning how the cell is supported during use.
First-use check
- Inspect the optical faces and both V-shaped end openings for chips, residue or handling marks.
- Place the cell in the intended holder and confirm stable seating before introducing the sample.
- Run a blank in the selected optical direction, then repeat after filling to confirm bubble-free coverage.
Fit and optical alignment
The stated 31 × 11 × 55 mm dimensions apply to the cell body only. Use them to check holder clearance and handling access, especially around both end openings, but do not treat them as a beam-height specification.
Z Height is not stated for this SKU. If your instrument or mount depends on a fixed beam center height, please check that separately before ordering.
View the English selection reference.

Solvents and cleaning
Clean the optical faces gently with a non-abrasive method suitable for glass. Keep hydrofluoric acid away from glass, and avoid hot strong alkalis and abrasive cleaners.
This cell uses adhesive-bonded Standard 80 construction. For this type, room-temperature water-based samples and buffer solutions are the usual direction. If your method involves organic solvents, aggressive chemicals, elevated temperature or prolonged contact, please check the full sample and cleaning conditions before use.
Included with this option
1 Glass Rectangular Sample Cell. The listed price is for one piece.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
If you need a different body size, optical path, opening arrangement or material, please send your drawing or holder details together with sample conditions and quantity. Send a product-selection enquiry with SKU MQQFL076 and the dimensions or handling requirements that matter for your setup.
Additional information
| Weight | 65 g |
|---|
You must be logged in to post a review.