Quartz rectangular sample cell with dual 9 mm and 6.2 mm optical paths, Four-Way Light geometry and 1.4 mL nominal capacity. Its compact open-at-both-ends body lets you choose between two path directions in one cell when building a custom holder or end-sealing arrangement. Sold as 1 piece.

In Stock
Add to Wishlist
Add to Wishlist
Shipping and order support
  • Worldwide delivery to door service, hassle free shipping
  • Contact us for quotation of bulk purchase discount
  • Custom design. Send us graphic drawing for solution
  • POs for Academics. Pay after delivery.
  • Availability and dispatch timing vary by item and quantity. Contact us to confirm timing for your order.

Description

MQQFC047 is a compact JGS1 quartz rectangular sample cell with two specified optical paths: 9 mm in one direction and 6.2 mm in the other. The Four-Way Light body gives optical access from four sides, and the open-through design leaves end sealing and sample handling to your own assembly. This combination is useful when one small cell body needs two selectable measurement directions.

Path Length
9 mm / 6.2 mm (dual path)
Sample Volume (Nominal)
1.4 mL
Opening Configuration
Open at Both Ends

Selection Specifications

Product KindSpecialized Cell
Cell TypeRectangular Sample Cell
Measurement ModeTransmission Spectroscopy
Path Length9 mm / 6.2 mm (dual path)
Light Transmission ConfigurationFour-Way Light
Wavelength Range — Lower Limit200 nm
Wavelength Range — Upper Limit2500 nm
Sample Volume (Nominal)1.4 mL
External Dimensions10 × 7.2 × 26 mm
Body Height26 mm
Base Dimensions10 × 7.2 mm
Internal Dimensions9 × 6.2 × 26 mm
MaterialQuartz
Material GradeJGS1
Fabrication MethodMolded 83
Opening ConfigurationOpen at Both Ends
Pack Quantity1 Piece

Choose this option

Choose this cell when your method needs a small rectangular chamber and you want to work with either a 9 mm or 6.2 mm path in the same body. Its compact outer size helps when fixture space is limited, while the open ends allow the loading and sealing method to be defined around your holder and procedure.

View the English selection reference.

What makes this option different

  • Dual optical paths: the body provides both 9 mm and 6.2 mm path directions in one cell.
  • Four-Way Light geometry: optical access is available from four sides of the rectangular body.
  • Compact size: the 10 × 7.2 × 26 mm exterior suits small fixtures and limited installation space.
  • Open at both ends: sealing and sample handling depend on the holder or end arrangement used in your system.

Structure and dimensions

Product dimensions for checking holder clearance and sample access.
Product dimensions for checking holder clearance and sample access.Open image ↗

Using this cell

Install the cell so the beam follows the path direction required by your method, and keep that orientation consistent between blank and sample. Because this body offers two path directions, it is useful to label the mounted orientation in your procedure or holder setup.

The cell is open at both ends, so filling, drainage and sample retention depend on the external end treatment. The 1.4 mL figure is a nominal cell volume for the body, not a minimum working volume.

First-use check

  1. Inspect all optical faces and the end openings before fitting the cell.
  2. Confirm which mounted orientation gives the required 9 mm or 6.2 mm path.
  3. Run a blank to check alignment, filling behaviour and bubble removal in the finished assembly.

Fit and optical alignment

Use the 10 × 7.2 × 26 mm exterior for holder clearance and support design. The 9 × 6.2 × 26 mm internal dimensions describe the chamber itself, not the opening required in the fixture.

Z Height is not listed, so beam-height compatibility should be checked from the actual mounted position rather than assumed from the 26 mm body height. Support the body carefully and avoid side pressure across the optical faces.

English selection reference
Selection reference ↗

Solvents and cleaning

This cell is listed with Molded 83 fabrication. Choose the cleaning and sample-contact conditions for the full assembly, including any end seals or fittings used with the open-through body.

Do not use hydrofluoric acid with quartz. Avoid hot strong alkalis and abrasive cleaning methods. Clean the optical faces gently, and review any aggressive solvent, heat or long contact-time use in the context of the complete mounted setup.

Included with this option

1 rectangular sample cell. The listed price is for one piece.

Availability and ordering

Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.

Discuss a custom version

We coordinate custom JGS1 quartz versions for alternative path combinations, chamber sizes, exterior dimensions and opening details. Send your drawing or labelled sketch, required orientation, sample conditions and quantity through the contact page if you need a related custom body or holder review.

Additional information

Weight50 g

Reviews

There are no reviews yet.

Be the first to review “(MQQFC047) Quartz Rectangular Sample Cell, 9/6.2 mm Dual Path, 1.4 mL, Open at Both Ends”

You may also like…

Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • SKU
  • Rating
  • Price
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Weight
  • Dimensions
  • Additional information
Click outside to hide the comparison bar
Compare