Site Navigation

(MQQFC033) Quartz Rectangular Sample Cell, 5 mm Path, 1 mL, Open at Both Ends

Weight50 g
SKU: MQQFC033

$359.00

In Stock

JGS1 quartz rectangular sample cell with a 5 mm optical path, Four-Way Light access and 1 mL nominal capacity. The body is open at both ends, so you can build it into your own holder, sealing method or sample-handling setup. Supplied as 1 piece.

In Stock
Add to Wishlist
Add to Wishlist
Shipping and order support
  • Worldwide delivery to door service, hassle free shipping
  • Contact us for quotation of bulk purchase discount
  • Custom design. Send us graphic drawing for solution
  • POs for Academics. Pay after delivery.
  • Availability and dispatch timing vary by item and quantity. Contact us to confirm timing for your order.

Description

MQQFC033 is a slim JGS1 quartz rectangular sample cell for methods that need a 5 mm optical path in a narrow body. Its Four-Way Light layout gives optical access from four sides, while the open-at-both-ends form leaves filling, sealing and mounting to your own fixture. The nominal capacity is 1 mL, which makes this model useful when you need a small rectangular chamber without built-in connections.

Path Length
5 mm
Sample Volume (Nominal)
1 mL
Opening Configuration
Open at Both Ends

Selection Specifications

Product KindSpecialized Cell
Cell TypeRectangular Sample Cell
Measurement ModeTransmission Spectroscopy
Path Length5 mm
Light Transmission ConfigurationFour-Way Light
Wavelength Range — Lower Limit200 nm
Wavelength Range — Upper Limit2500 nm
Sample Volume (Nominal)1 mL
External Dimensions7 × 7 × 45 mm
Body Height45 mm
Base Dimensions7 × 7 mm
Internal Dimensions5 × 5 × 45 mm
MaterialQuartz
Material GradeJGS1
Fabrication MethodMolded 83
Opening ConfigurationOpen at Both Ends
Pack Quantity1 Piece

Choose this option

Choose MQQFC033 when your setup is built around a 5 mm path and you want a straight rectangular cell body that can be integrated into custom hardware. The 7 × 7 mm outer section helps where holder space is limited, and the four-side optical access is useful when the measurement geometry needs side access rather than a single fixed window pair.

View the English selection reference. Also available in the product gallery. Group photographs illustrate other options in the series.

What makes this option different

  • 5 mm optical path suits methods specified around that path length.
  • Four-Way Light configuration allows optical access from four sides of the rectangular body.
  • Open at both ends leaves sealing, filling and retention to your own holder or assembly.
  • 7 × 7 × 45 mm outer size with 5 × 5 × 45 mm internal dimensions helps you separate fixture clearance from chamber space.

Using this cell

Install the cell so the beam travels through the intended 5 mm path. Because the body is open at both ends, liquid use depends on the fixture you build around it, including how the sample is introduced, retained and cleared of bubbles before measurement.

The 1 mL value is the nominal chamber capacity. It should not be treated as the minimum working fill, because actual working volume depends on your end sealing, holder geometry and any added parts outside the supplied quartz body.

First-use check

  1. Inspect the optical faces, end edges and open ends for chips, residue or handling marks.
  2. Place the cell in the intended holder and verify beam position with a blank.
  3. For liquid use, confirm that your filling and sealing arrangement retains the sample properly and leaves the beam area free of bubbles.

Fit and optical alignment

Use the 7 × 7 × 45 mm outer dimensions to check holder clearance and support points. The 5 × 5 × 45 mm internal dimensions describe the sample chamber, not the opening required in your fixture.

Z Height is not listed for this model. If your instrument or holder depends on a defined beam-center height, check that from the mounted geometry rather than assuming it from the body height alone. Support the cell evenly and avoid point loading at the optical faces or end edges.

English selection reference
Selection reference ↗

Solvents and cleaning

This cell is made in Molded 83 construction. That fabrication is commonly selected for organic-solvent methods and heated applications, but the suitability of the full setup also depends on any seals, fittings or supports added around the cell body.

Keep hydrofluoric acid away from quartz. Avoid hot strong alkalis and abrasive cleaning methods. Clean the optical faces gently with non-abrasive optical tissue and a cleaning liquid suitable for your method.

Included with this option

1 rectangular sample cell, SKU MQQFC033. The listed price is for one piece.

Availability and ordering

Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.

Discuss a custom version

We can review custom JGS1 quartz versions of this type for changes to path length, body dimensions, capacity, optical layout, closures or connection details. Please send your drawing or holder information, critical dimensions, sample conditions and required quantity through our contact page.

Additional information

Weight50 g

Reviews

There are no reviews yet.

Be the first to review “(MQQFC033) Quartz Rectangular Sample Cell, 5 mm Path, 1 mL, Open at Both Ends”

You may also like…

Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • SKU
  • Rating
  • Price
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Weight
  • Dimensions
  • Additional information
Click outside to hide the comparison bar
Compare