Site Navigation

(MQAVC001) Quartz Atomic Vapor Cell, 60 mm path, Angled Cylindrical Chamber

Weight250 g
SKU: MQAVC001

$948.00

In Stock

JGS1 quartz atomic vapor cell with a 60 mm optical path, 19 mm outside diameter and inclined end faces. The 62 mm body has a single fill stem projecting 8 mm, with 4 mm OD and 2 mm ID, for planning body support and stem clearance. One cell supplied.

In Stock
Add to Wishlist
Add to Wishlist
Shipping and order support
  • Worldwide delivery to door service, hassle free shipping
  • Contact us for quotation of bulk purchase discount
  • Custom design. Send us graphic drawing for solution
  • POs for Academics. Pay after delivery.
  • Availability and dispatch timing vary by item and quantity. Contact us to confirm timing for your order.

Description

MQAVC001 is a quartz atomic vapor cell for atomic spectroscopy with a 60 mm optical path, a 19 mm outer diameter body and a single fill stem. It is a practical choice when you need the longer path but also need to match a larger cylindrical body and leave room above the cell for filling or final assembly work. Supplied as one JGS1 quartz cell, this option suits setups built around the cell envelope as much as the optical length.

Path Length
60 mm
Cell Type
Atomic Vapor Cell
Opening Configuration
Single Fill Stem

Selection Specifications

Product KindSpecialized Cell
Cell TypeAtomic Vapor Cell
Measurement ModeAtomic Spectroscopy
Path Length60 mm
Wavelength Range — Lower Limit200 nm
Wavelength Range — Upper Limit2500 nm
Outer Diameter (OD)19 mm
MaterialQuartz
Material GradeJGS1
Tube Outer Diameter (OD)4 mm
Tube Inner Diameter (ID)2 mm
Fabrication MethodMolded 83
Opening ConfigurationSingle Fill Stem
Wall Thickness1 mm
Pack Quantity1 Piece
Package Contents1 × Quartz Atomic Vapor Cell

Choose this option

Choose MQAVC001 when your fixture is designed around a 19 mm cylindrical body and a 60 mm path, and when the fill stem needs to remain accessible from the top. The stem dimensions are also useful at the ordering stage, because they let you check tubing, sealing hardware or shielding clearance before the cell is built into the apparatus.

What makes this option different

  • 60 mm optical path for atomic spectroscopy layouts that use this longer absorption length.
  • 19 mm outer diameter body for holders or clamps sized around a larger cylindrical envelope.
  • Single fill stem with 4 mm OD and 2 mm ID for planning the access point and connected hardware.
  • Angled end geometry with a 79° annotated feature that should be checked against nearby mounting space.

Using this cell

Handle the cell by the main body and avoid putting load on the fill stem. The stem is part of the working geometry, so filling, sealing and any gas-handling steps should be planned around the final assembly you intend to use.

This page covers the quartz cell itself. Gas composition, pressure limit, final sealing details and working fill conditions are not specified here, so those points should be defined for the complete setup if they matter to your experiment.

First-use check

  1. Inspect the optical faces, body and fill stem for chips, residue or transport damage.
  2. Test the body support and clearance around the projecting stem before connecting process hardware.
  3. Align the beam through the intended sample chamber, clear of the chamber edges, and establish the background in the final measurement orientation.

Fit and optical alignment

View the English selection reference.

Check the 19 mm body diameter and the 62 mm body length against your holder or heater block, then check the separate clearance needed for the fill stem. The tube wall is specified as 1 mm. The drawing also shows the stem projecting 8 mm, which matters when the cell sits inside a close-fitting clamp, shield or enclosure.

Z Height is not specified for this cell. If your instrument depends on a defined beam-center height, send the holder or beam geometry for review rather than assuming fit from the body diameter alone.

English selection reference
Selection reference ↗

Solvents and cleaning

Molded 83 construction is often chosen for quartz cells used in methods that may involve organic solvents or heated process conditions. Cleaning suitability should be considered for the complete assembly, especially if your process adds sealing materials or external fittings.

Keep hydrofluoric acid away from quartz. Avoid hot strong alkalis and abrasive cleaning materials, and clean the optical faces gently with non-abrasive lab tissue or another suitable non-scratching method.

Included with this option

1 Quartz Atomic Vapor Cell.

Availability and ordering

Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.

Discuss a custom version

We coordinate custom JGS1 quartz production for requirements involving path length, body size, openings, stem layout and related geometry for atomic vapor cell use. Send a drawing or labelled sketch with the critical dimensions, holder information, sample conditions and target quantity.

Send a product-selection enquiry with SKU MQAVC001 if you need a different body diameter, stem arrangement or fit for a specific apparatus.

Additional information

Weight250 g

Reviews

There are no reviews yet.

Be the first to review “(MQAVC001) Quartz Atomic Vapor Cell, 60 mm path, Angled Cylindrical Chamber”

You may also like…

Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • SKU
  • Rating
  • Price
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Weight
  • Dimensions
  • Additional information
Click outside to hide the comparison bar
Compare