(MQAVC006) Quartz Atomic Vapor Cell, 1 mm path, 720 µL nominal capacity, Single Fill Stem
Description
MQAVC006 is a JGS1 quartz atomic vapor cell for atomic spectroscopy work that uses a 1 mm optical path in a compact square-body format. It combines a Two-Way Light layout, a 720 µL nominal capacity and a single fill stem, giving you a defined chamber style when you need a short optical path and direct access from above.
This model uses Molded 83 fabrication with supplier-described integrated-forming construction. It is sold as one cell.
- Path Length
- 1 mm
- Sample Volume (Nominal)
- 720 µL
- Opening Configuration
- Single Fill Stem
Selection Specifications
| Product Kind | Specialized Cell |
|---|---|
| Cell Type | Atomic Vapor Cell |
| Measurement Mode | Atomic Spectroscopy |
| Path Length | 1 mm |
| Light Transmission Configuration | Two-Way Light |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 720 µL |
| Cell Body Dimensions | 50 × 10 × 50 mm |
| Internal Dimensions | 30 × 1 × 30 mm |
| Material | Quartz |
| Material Grade | JGS1 |
| Tube Outer Diameter (OD) | 6 mm |
| Tube Inner Diameter (ID) | 4 mm |
| Fabrication Method | Molded 83 |
| Opening Configuration | Single Fill Stem |
| Pack Quantity | 1 Piece |
| Package Contents | 1 × Quartz Atomic Vapor Cell |
Choose this option
Choose MQAVC006 when your method is built around a 1 mm path and you want a block-style vapor cell rather than a cylindrical body. The 50 × 10 × 50 mm bare body gives a clear holder footprint, while the top stem separates chamber access from the main optical block so you can plan fixture space and handling more easily.
What makes this option different
- 1 mm optical path for methods designed around a short transmission length.
- Two-Way Light configuration for transmission through opposing optical faces.
- 720 µL nominal capacity for planning chamber scale without treating it as a minimum working fill.
- 50 × 10 × 50 mm body with single fill stem for setups that need a compact block body plus top access.
Using this cell
Fill and use the cell in the intended optical direction for your method, keeping the same orientation for blank and sample measurements. The single stem is the access point shown for this model, so any filling, sealing or gas-handling approach should be planned around that one-stem arrangement.
Support the main body during handling and avoid side load on the projecting stem. The cell geometry does not establish a supplied gas composition, closure, pressure rating or minimum working volume, so those requirements should be defined separately if they are important to your process.
First-use check
- Inspect the optical faces, body and fill stem for chips, residue or transport damage.
- Test the body support and clearance around the projecting stem before connecting process hardware.
- Align the beam through the intended sample chamber, clear of the chamber edges, and establish the background in the final measurement orientation.
Fit and optical alignment
View the English selection reference.
The bare body is 50 × 10 × 50 mm, and the internal chamber is 30 × 1 × 30 mm. The fill stem is shown as 30 mm long with 6 mm outer diameter and 4 mm inner diameter, so top clearance and access space should be checked separately from the holder pocket for the body.
Z Height is not available for this SKU. If your instrument has a fixed beam-center requirement, verify that fit from your holder or a current reference cell instead of assuming it from the body size.

Solvents and cleaning
Molded 83 quartz is commonly chosen for methods that may involve organic solvents or temperature-controlled work, but the suitable sample and cleaning routine still depends on the complete assembly and actual operating conditions. If your method involves demanding chemistry, extended contact time or elevated temperature, please check suitability before ordering.
Do not use hydrofluoric acid with quartz. Avoid hot strong alkalis and abrasive cleaners, and clean the exterior optical faces gently with non-abrasive optical tissue.
Included with this option
1 Quartz Atomic Vapor Cell.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
If you need a different chamber size, path length, body envelope or stem arrangement, send a labelled drawing or sketch with the critical dimensions and operating conditions. Holder details are helpful when the cell must fit an existing mounting space.
Send a product-selection enquiry with SKU MQAVC006, your drawing or holder details, sample conditions, quantity and delivery destination.
Additional information
| Weight | 3600 g |
|---|
You must be logged in to post a review.










Reviews