Site Navigation

(MQQCU007) Shallow Quartz Cell, 10 mm Path, 600 µL, Three Optical Faces

Weight50 g
SKU: MQQCU007

$179.00

In Stock

Shallow quartz sample cell with a 10 mm optical path, 600 µL nominal capacity and a 24 × 14 × 5 mm body. The transmitting front, back and bottom faces provide optical access for a fixture designed around this low-profile geometry. This is the powder-fused option, supplied as one cell.

In Stock
Add to Wishlist
Add to Wishlist
Shipping and order support
  • Worldwide delivery to door service, hassle free shipping
  • Contact us for quotation of bulk purchase discount
  • Custom design. Send us graphic drawing for solution
  • POs for Academics. Pay after delivery.
  • Availability and dispatch timing vary by item and quantity. Contact us to confirm timing for your order.

Description

MQQCU007 is a shallow, open-top quartz cell with a stated 10 mm optical path and 600 µL nominal capacity. The 24 × 14 × 5 mm body has transmitting front, back and bottom faces, giving you access to the sample region from the sides and below in a suitable fixture.

This is the powder-fused construction option in this cell format. It is supplied as one cell; the low-profile geometry and three transmitting faces are the main points to match to your optical arrangement.

Path Length
10 mm
Sample Volume (Nominal)
600 µL
Opening Configuration
Open Top

Selection Specifications

Product KindCuvette
Cell TypeRectangular Sample Cell
Measurement ModeUV/Vis Spectroscopy
Path Length10 mm
Light Transmission ConfigurationThree-Way Light
Optical Window LayoutFront; Back; Bottom
Sample Volume (Nominal)600 µL
External Dimensions24 × 14 × 5 mm
Cell Body Dimensions24 × 14 × 5 mm
External Dimensions ScopeBody Only
Body Height5 mm
MaterialQuartz
Opening ConfigurationOpen Top
Pack Quantity1 Piece
Package Contents1 × Quartz Rectangular Sample Cell

Choose this option

Choose MQQCU007 when your setup needs a shallow sample region with front/back and bottom optical access. Check that the support leaves the required faces unobstructed and that filling access remains comfortable once the cell is installed.

What makes this option different

  • Three transmitting faces: front, back and bottom optical access for the intended illumination and detection geometry.
  • 24 × 14 × 5 mm body: a shallow form that needs a fixture matched to its seating area and beam position.
  • 10 mm stated optical path: use the intended measurement orientation; establish the liquid path separately if measuring in another direction.
  • 600 µL nominal capacity: plan the working fill to cover the illuminated region without bubbles.
  • Powder-fused option: the joining method selected for this shallow cell; review the liquid and cleaning conditions for your method.

Structure and dimensions

MQQCU007 shallow cell body with the 24 × 14 × 5 mm exterior dimensions.
MQQCU007 shallow cell body with the 24 × 14 × 5 mm exterior dimensions.Open image ↗

Using this cell

Support the cell without obscuring the optical face used by the method. Fill from the open top, remove trapped bubbles and keep the cell in the same orientation for blank and sample measurements.

The 600 µL figure is a nominal capacity rather than a verified minimum working fill. Set the liquid level and beam footprint for the installed arrangement, and keep exterior droplets, fingerprints and residue off the optical faces.

First-use check

  • Inspect the optical faces, rim and sample region for chips or residue.
  • Seat the cell and check that the selected optical face remains clear of the support.
  • Run a suitable blank, then recheck fill level and bubbles in the same orientation.

Fit and optical alignment

Check the complete 24 × 14 × 5 mm body envelope and the available space for loading and rinsing. Z Height is not specified for this SKU; establish the beam position from your actual fixture.

View the English selection reference. Send a holder drawing or an existing cell reference if you need a different support or optical arrangement.

English selection reference
Selection reference ↗

Solvents and cleaning

Select the liquid and cleaning routine for the powder-fused cell and your handling conditions. For organic solvents, aggressive liquids, heating or prolonged soaking, send the liquid, concentration, temperature and contact time for a suitability review.

Keep hydrofluoric acid away from quartz. Avoid hot strong alkalis and abrasive cleaners. Clean exterior optical faces gently with non-abrasive optical tissue.

Included with this option

One MQQCU007 shallow quartz sample cell. The listed price is for one cell.

Availability and ordering

You can order the listed specification directly, or contact us to check availability and dispatch timing before ordering. If your selected option is temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, please contact us before checkout; preparation time is separate from shipping transit time.

Discuss a custom version

Send the required path, capacity, external envelope, windows or Z Height, closure/interface details and fabrication/tolerance requirements. Custom material is generally JGS1 quartz. Prototype orders are usually 2–4 cells, with feasibility, specification, quantity, price and timing confirmed for the project.

Send a product-selection enquiry with SKU MQQCU007, your drawing or holder details, sample conditions, quantity and delivery destination.

Additional information

Weight50 g

Reviews

There are no reviews yet.

Be the first to review “(MQQCU007) Shallow Quartz Cell, 10 mm Path, 600 µL, Three Optical Faces”

You may also like…

Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • SKU
  • Rating
  • Price
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Weight
  • Dimensions
  • Additional information
Click outside to hide the comparison bar
Compare