(MQQFC030) Quartz Rectangular Sample Cell, 5/1 mm Dual Path, 225 µL, Open at Both Ends
Description
MQQFC030 is a JGS1 quartz rectangular sample cell for setups that need two defined optical directions in the same compact body. It combines 5 mm and 1 mm path directions, a Four-Way Light layout and an open-at-both-ends sample chamber, so you can build the surrounding holder, sealing and loading method around the cell instead of buying a finished flow assembly.
Its 225 µL nominal capacity and 5 × 1 × 45 mm internal chamber give you a clear starting point for planning sample handling, while the 7.5 × 3.5 × 45 mm exterior helps you check fixture clearance. Because this is a bare open cell body, beam height, end sealing and the final mounted operating volume remain part of your own assembly design.
- Path Length
- 5 mm / 1 mm (dual path)
- Sample Volume (Nominal)
- 225 µL
- Opening Configuration
- Open at Both Ends
Selection Specifications
| Product Kind | Specialized Cell |
|---|---|
| Cell Type | Rectangular Sample Cell |
| Measurement Mode | Transmission Spectroscopy |
| Path Length | 5 mm / 1 mm (dual path) |
| Light Transmission Configuration | Four-Way Light |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 225 µL |
| External Dimensions | 7.5 × 3.5 × 45 mm |
| Body Height | 45 mm |
| Base Dimensions | 7.5 × 3.5 mm |
| Internal Dimensions | 5 × 1 × 45 mm |
| Material | Quartz |
| Material Grade | JGS1 |
| Fabrication Method | Molded 83 |
| Opening Configuration | Open at Both Ends |
| Pack Quantity | 1 Piece |
Choose this option
Choose MQQFC030 when your method benefits from two path directions in one rectangular cell and you need direct access from both ends. This format suits custom fixtures, end supports or special loading arrangements where the cell body must stay small but still offer side optical access and a defined internal chamber.
View the English selection reference. Also available in the product gallery. Group photographs illustrate other options in the series.
What makes this option different
- Two path directions in one body: the cell provides both 5 mm and 1 mm optical paths, so orientation matters during mounting and measurement.
- Open at both ends: sample loading and retention are handled by your holder or end arrangement rather than by built-in caps or fittings.
- Four-Way Light layout: optical access from four sides supports measurement geometries that need more than a single transmission direction.
- Compact rectangular format: the small external envelope helps when the cell must fit a dedicated fixture with limited clearance.
- Molded 83 fabrication: this construction is suited to quartz cuvette applications that need a formed quartz body rather than a disposable insert.
Structure and dimensions

Using this cell
Load the sample with a method that matches your own end support and sealing approach. Since the chamber is open at both ends, sample retention, filling direction and bubble control depend on how the cell is mounted and how the liquid is introduced.
Keep the orientation consistent so the beam always travels through the intended 5 mm or 1 mm direction. Use the same orientation for blank and sample measurements to keep the optical setup consistent.
First-use check
- Inspect the optical faces and end edges for cleanliness before mounting.
- Check that the holder supports the cell securely without point loading or over-tight clamping.
- Run a blank in the intended orientation and confirm stable filling, sample retention and bubble-free optical access.
Fit and optical alignment
Use the 7.5 × 3.5 × 45 mm external size to check holder clearance and support points, and use the 5 × 1 × 45 mm internal dimensions to understand the sample chamber itself. The holder should support the body evenly without excessive clamping force on the quartz faces or edges.
Z Height is not specified for this cell, so do not assume beam position from the body height alone. If your instrument or holder has a fixed beam line, verify the mounted beam alignment in the actual fixture before ordering.

Solvents and cleaning
This cell uses Molded 83 fabrication with a JGS1 quartz body. Choose your cleaning method with the full assembly in mind, including any seals, supports or other parts that contact the sample in your setup.
Do not use hydrofluoric acid with quartz. Avoid hot strong alkalis and abrasive cleaning methods. Clean the optical faces gently with non-abrasive optical tissue and a cleaning liquid suitable for both the sample residue and the mounted assembly.
Included with this option
1 MQQFC030 rectangular sample cell. The listed price is for one piece.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We coordinate custom JGS1 quartz production for changes to path length, body dimensions, chamber geometry, openings or fabrication requirements. If you need a different mounting fit, send your holder drawing or labelled sketch, beam position, critical dimensions, sample conditions and target quantity for review.
Send a product-selection enquiry with SKU MQQFC030 and your application details.
Additional information
| Weight | 50 g |
|---|