(C024CR) Quartz Fluorescence Cuvette, 2 mm Path, 700 µL
Description
C024CR is a JGS3 quartz fluorescence cuvette for infrared and fluorescence measurements, combining a 2 mm optical path with Four-Way Light access in a slim rectangular body. Its 700 µL nominal capacity suits small sample volumes, and the open-top format gives direct access to the sample chamber for filling and inspection. A closure is included with this option.
- Path Length
- 2 mm
- Sample Volume (Nominal)
- 700 µL
- Opening Configuration
- Open Top
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Fluorescence Cuvette |
| Measurement Mode | Infrared Spectroscopy; Fluorescence Spectroscopy |
| Path Length | 2 mm |
| Light Transmission Configuration | Four-Way Light |
| Wavelength Range — Lower Limit | 260 nm |
| Wavelength Range — Upper Limit | 3500 nm |
| Sample Volume (Nominal) | 700 µL |
| External Dimensions | 12.5 × 4.5 × 45 mm |
| Uncapped Cell Dimensions | 12.5 × 4.5 × 45 mm |
| External Dimensions Scope | Uncapped Cell |
| Material | Quartz |
| Material Grade | JGS3 |
| Closure Type | Lid |
| Closure Included | Yes |
| Opening Configuration | Open Top |
Choose this option
Choose C024CR when your method needs a short 2 mm path length together with optical access from four sides. This combination is useful for setups where excitation and collection geometry matters, while the narrow body format helps when your holder or fixture accepts a slim rectangular cell. The listed wavelength range is 260–3500 nm for the stated infrared and fluorescence uses.
What makes this option different
- 2 mm optical path: match the measurement method to this transmission distance and align the beam through the sample region.
- Four-Way Light: use the available side faces to arrange illumination and collection in a measurement geometry suitable for this cell.
- 700 µL nominal capacity: plan the working fill and beam footprint together so liquid covers the illuminated region; nominal capacity is not a minimum working fill.
- Open-top access: load and rinse through the sample opening, leaving room above the body for filling and any accompanying closure.
- Supplier-described fused integrated construction: keep the body assembled for routine cleaning and rinse through the sample opening, using liquids suitable for the complete quartz assembly.
Using this cell
Fill the sample chamber from the top and keep the optical faces clear in the beam area. Before measurement, check for bubbles, droplets, suspended matter or dried residue that could interfere with the optical path.
If your method depends on a defined excitation and collection direction, keep the same orientation for blank and sample measurements. The 700 µL figure is a nominal capacity, not a minimum working volume, so low-fill methods should be checked against the actual beam position in your instrument.
First-use check
Inspect the optical faces and edges for chips, cracks or visible contamination before first use. Rinse with a liquid suitable for your method, test-fit the empty cell in the holder, and run a blank in the same orientation you plan to use for the sample.
Fit and optical alignment
The listed 12.5 × 4.5 × 45 mm dimensions apply to the uncapped cell body. Use those dimensions to check holder seating, side clearance and top access, especially if your fixture is designed around a narrow rectangular cell format.
Z Height is not listed for this SKU. If your holder has a fixed beam-center height or limited vertical adjustment, confirm that the beam will pass through the intended sample region before ordering or before routine use.
Solvents and cleaning
For general construction background, see Compare fabrication options. Specific chemical limits for this exact assembled cell are not listed here, so please check suitability for your sample, concentration, temperature and contact time if your method uses aggressive chemicals or demanding cleaning conditions.
Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaning. Clean the optical faces gently with non-abrasive optical tissue, and choose a cleaning routine suitable for the assembled cell and its included closure.
Included with this option
This configuration includes an accompanying closure. Confirm the cell quantity and any separately specified accessories covered by your order.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
If you need a different path length, body size, sample volume, optical window arrangement or holder fit, we can review a custom quartz version. Send a drawing or labelled sketch, holder or instrument details, critical dimensions, wavelength range and sample conditions through our contact page, and include part number C024CR.
Additional information
| Weight | 30 g |
|---|
You must be logged in to post a review.






Reviews
There are no reviews yet.