(C0.24TS1) Quartz Screw-Top Cuvette, 0.2 mm Path, 70 µL
Original price was: $608.00.$548.00Current price is: $548.00.
C0.24TS1 is a JGS1 quartz screw-top cuvette with a 0.2 mm optical path, 70 µL nominal capacity and Four-Way Light layout. Its slim 12.5 × 2.7 mm measurement body is paired with an M10 threaded opening, so path length, body fit and top access should be selected together. Supplied as 1 cuvette.
Description
C0.24TS1 is a specialised JGS1 quartz screw-top cuvette built around a very short 0.2 mm optical path and a 70 µL nominal capacity. The Four-Way Light layout provides optical access from multiple sides, while the M10 threaded opening gives a larger screw-top access point above a slim measurement body. This is a good choice when your method requires this exact short-path geometry rather than a general-purpose cuvette shape.
- Path Length
- 0.2 mm
- Sample Volume (Nominal)
- 70 µL
- Closure Type
- Screw Cap
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Screw-Top Cuvette |
| Measurement Mode | Fluorescence Spectroscopy |
| Pack Quantity | 1 Piece |
| Path Length | 0.2 mm |
| Light Transmission Configuration | Four-Way Light |
| Sample Volume (Nominal) | 70 µL |
| Body Height | 35 mm |
| Overall Height with Closure | 58 mm |
| Base Dimensions | 12.5 × 2.7 mm |
| Material | Quartz |
| Material Grade | JGS1 |
| Closure Type | Screw Cap |
| Port Thread | M10 |
| Fabrication Method | Molded 83 |
Choose this option
Choose C0.24TS1 when the path length itself is the deciding factor and you need that 0.2 mm path in a quartz screw-top cell with multi-side optical access. The narrow 12.5 × 2.7 mm body helps define how the cell sits in a holder, while the M10 threaded opening gives a different top profile from the measuring section below it.
What makes this option different
- 0.2 mm optical path for methods designed around a very short transmission path.
- Four-Way Light layout with optical access on multiple sides of the cell.
- 70 µL nominal capacity in a compact sample chamber.
- M10 threaded opening above a 12.5 × 2.7 mm body so top access and holder fit should be checked separately.
- Molded 83 fabrication designation with a construction style commonly selected for organic-solvent methods and temperature-controlled work.
Using this cell
Use this cuvette when your procedure is written for a 0.2 mm path. Fill carefully so the sample covers the active optical region and check for trapped air before measurement. In a small chamber like this, a bubble or residue film can affect the usable path quickly.
The opening is specified as M10, but the supplied closure details are not listed here. If your method depends on a particular cap, liner or sealing arrangement, please confirm that before ordering.
First-use check
- Inspect the optical faces and opening area for dust or residue before filling.
- Check that the body seats properly in your holder and that the upper threaded section clears nearby parts.
- Run a blank with your method solvent before measuring samples.
Fit and optical alignment
The measurement body is 12.5 × 2.7 mm at the base, with a 35 mm body height and 58 mm overall height with cap. That makes both the lower holder fit and the clearance around the threaded top important. Treat the slim body and the enlarged threaded opening as separate parts when checking surrounding space.
Z Height is not listed for this cuvette. Do not assume instrument compatibility from the Four-Way Light layout alone; if your fluorimeter or holder uses a fixed beam height, compare it with your current cell or ask before ordering.
Solvents and cleaning
Molded 83 is the fabrication designation used for this cuvette. This type is commonly chosen for methods involving organic solvents and for applications that may include temperature control, but the exact chemical limits of this assembled cell are not listed here.
Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaning. Clean the optical faces gently with non-abrasive optical tissue, and check compatibility for the full cell-and-closure assembly before using aggressive reagents or cleaning solvents.
Included with this option
Price is for 1 cuvette. Other package contents are not specified here.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We coordinate custom JGS1 quartz production for requirements involving dimensions, optical path length, sample volume, optical windows or Z Height, closures and connections, fabrication and tolerances. Send a dimensioned drawing or labelled sketch and identify the dimensions and tolerances that matter to your setup. Discuss your requirements and quote part number C0.24TS1.
Additional information
| Weight | 30 g |
|---|
You must be logged in to post a review.









Reviews