(C054TS4) Quartz Flow Cell, 5 mm / 10 mm (dual path) Path, 1.2 mL
Original price was: $313.00.$282.00Current price is: $282.00.
C054TS4 is a JGS1 quartz flow cell for UV/Vis work with a 5 mm / 10 mm dual optical path, Four-Way Light geometry and 1.2 mL nominal capacity. Two opposed M6 threaded end openings support straight-through flow-line layout. Sold as 1 cell per listed price unit.
Description
C054TS4 is a quartz flow cell for UV/Vis setups that need a dual-path optical layout together with a larger nominal cell volume than compact micro-flow formats. It combines a 5 mm primary path, a 10 mm secondary path, Four-Way Light access and a 1.2 mL nominal capacity in one threaded flow-through body.
The JGS1 quartz cell supports the stated 200–2500 nm application range. This listing is sold as 1 cell per listed price unit.
- Path Length
- 5 mm / 10 mm (dual path)
- Sample Volume (Nominal)
- 1.2 mL
- Opening Configuration
- Two Threaded End Openings
Selection Specifications
| Product Kind | Flow Cell |
|---|---|
| Cell Type | Flow Cell |
| Measurement Mode | UV/Vis Spectroscopy |
| Path Length | 5 mm / 10 mm (dual path) |
| Light Transmission Configuration | Four-Way Light |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 1.2 mL |
| Material | Quartz |
| Material Grade | JGS1 |
| Closure Type | Screw Cap |
| Port Count | 2 |
| Port Thread | M6 |
| Fabrication Method | Molded 83 |
| Opening Configuration | Two Threaded End Openings |
Choose this option
Choose C054TS4 when your method needs both 5 mm and 10 mm optical paths in the same flow cell, and when a moderate internal volume suits your liquid-handling plan better than a very small-volume body. The opposed M6 end openings also help when your tubing layout is easiest with straight-through end connections rather than side access.
What makes this option different
- Dual optical path with 5 mm and 10 mm path lengths in one cell format.
- Four-Way Light layout for optical access from four faces of the cell body.
- 1.2 mL nominal capacity for methods that need more internal cell volume than compact low-volume formats.
- Two opposed M6 end openings for a defined threaded connection layout at both ends.
Using this cell
Connect the liquid line through the two opposed M6 threaded end openings and fill the cell gradually so the sample reaches the optical region without leaving bubbles in the illuminated section. After the flow path is fully wetted, set the blank under the same operating conditions you will use for measurement.
The 1.2 mL figure is the nominal volume of the cell itself. Total liquid held by the full system will also depend on your tubing, fittings and any additional upstream or downstream components.
No pressure limit is stated for this option, so use in a pressurized circuit should be checked against your own fittings, seals and operating conditions.
First-use check
- Inspect the quartz faces and threaded port areas for chips, residue or transport damage.
- Verify that your fittings match the M6 threaded openings.
- Flush with a suitable blank or process liquid and inspect the optical region for trapped bubbles.
- Confirm beam alignment through the intended optical path in your holder or measurement fixture.
Fit and optical alignment
This format is useful when you need four optical access faces and end-to-end plumbing in the same cell body. The opposed port layout can simplify tubing runs, but you should still check the space needed for fittings and bend radius around both ends of the cell.
Z Height is not established for this SKU, so do not assume holder fit from the optical path values alone. If your instrument or fixture requires a fixed beam height, please confirm that dimension before ordering.
Solvents and cleaning
Molded 83 quartz is commonly selected for methods that may involve organic solvents and temperature-controlled work. Chemical suitability still depends on the complete wetted assembly, including the cell, fittings and any seals used in your setup.
Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaning. Use a cleaning solvent and procedure that are suitable for the full assembled flow path.
Included with this option
1 cuvette per listed price unit. If you need a supplied closure or other accessory, contact us before ordering.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We coordinate custom JGS1 quartz production for requirements involving dimensions, optical path length, sample volume, optical windows or Z Height, closures and connections, fabrication and tolerances. Send a labelled drawing or sketch with holder details, sample conditions and the dimensions that matter to your installation. Discuss your requirements and quote part number C054TS4.
Additional information
| Weight | 30 g |
|---|
You must be logged in to post a review.






Reviews
There are no reviews yet.