(C352CR) Quartz Large-Window Cuvette, 35 mm Path, 5.3 mL
Original price was: $90.00.$81.00Current price is: $81.00.
C352CR is a JGS1 quartz large-window cuvette for UV/Vis spectroscopy with a 35 mm optical path, Two-Way Light layout and 5.3 mL nominal capacity. Its open-top body gives direct access for filling, rinsing and visual inspection of the sample chamber. Sold as 1 cuvette per price unit.
Description
C352CR is a JGS1 quartz large-window cuvette for UV/Vis spectroscopy with a 35 mm optical path, Two-Way Light geometry and 5.3 mL nominal capacity. The open-top body gives you direct access to the sample chamber, while the slim internal section keeps this long-path option more compact than a broader high-volume chamber.
This version suits methods that call for a 35 mm transmission path and a manually filled open cell. It is also useful when holder space is limited, because the uncapped body remains compact at 37.5 × 7.5 × 40 mm.
- Path Length
- 35 mm
- Sample Volume (Nominal)
- 5.3 mL
- Opening Configuration
- Open Top (Cell Body)
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Large-Window Cuvette |
| Measurement Mode | UV/Vis Spectroscopy |
| Path Length | 35 mm |
| Light Transmission Configuration | Two-Way Light |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 5.3 mL |
| External Dimensions | 37.5 × 7.5 × 40 mm |
| Uncapped Cell Dimensions | 37.5 × 7.5 × 40 mm |
| Overall Height without Closure | 40 mm |
| External Dimensions Scope | Uncapped Cell |
| Body Height | 40 mm |
| Internal Dimensions | 34.5 × 5 × 38.5 mm |
| Material | Quartz |
| Material Grade | JGS1 |
| Opening Configuration | Open Top (Cell Body) |
Choose this option
Choose C352CR when you need a long 35 mm optical path in an open-top quartz cell that is still relatively compact in body size and nominal volume. The sample chamber is directly accessible from above for pipetting, rinsing and visual checks, and the listed 5.3 mL nominal capacity helps you judge whether this chamber format suits your method without moving to a much wider body.
What makes this option different
- 35 mm optical path for UV/Vis methods built around a longer transmission distance.
- Two-Way Light layout for straight-through optical use along the defined measurement axis.
- Open-top chamber for direct filling, rinsing and viewing of the sample region from above.
- 5.3 mL nominal capacity paired with a narrow internal section rather than a broad large-volume body.
- Powder-fused construction as the supplier’s stated construction term, relevant when you compare fabrication styles for routine use and cleaning approach.
- Compact uncapped body at 37.5 × 7.5 × 40 mm for holder and compartment clearance checks.
Using this cell
Fill the cell from the open top and make sure the liquid level covers the optical path used in your instrument. The 5.3 mL figure is a nominal capacity, not a minimum working volume, so partial-fill methods should be checked against the actual beam position in your setup.
Before measurement, inspect the sample region for bubbles or residue and keep the same orientation for blank and sample runs. Handle the cell by non-optical surfaces where possible, and rinse promptly after use so deposits do not dry on the chamber walls or optical faces.
First-use check
Inspect the chamber and optical faces for dust, residue or handling marks before first use. Rinse with a suitable liquid for your method, place the empty cell in the holder to confirm seating and beam access, and run a blank before routine measurements.
Fit and optical alignment
The uncapped outer body measures 37.5 × 7.5 × 40 mm. Use these dimensions to check whether the cell can seat in your holder, whether the compartment accepts the 7.5 mm body width, and whether you have enough top clearance to fill and remove an open cell comfortably.
The listed dimensions describe the bare cell body rather than a lid-installed assembly. Z Height is not stated for this SKU, so if your spectrometer or accessory has a fixed beam-center height, confirm that requirement before ordering instead of relying on overall body height alone.
Solvents and cleaning
This cuvette is made from JGS1 quartz, with the supplier describing the construction as powder-fused. In practical use, treat the cell as a precision quartz sample chamber: use cleaning liquids that suit your method, rinse thoroughly, and avoid letting residues dry inside the narrow chamber. For general fabrication background, see Compare fabrication options.
Specific chemical compatibility limits for this exact SKU are not stated here. Do not use hydrofluoric acid on quartz, and avoid hot strong alkalis and abrasive cleaning materials. Wipe the optical faces gently with non-abrasive optical tissue.
Included with this option
1 cuvette per listed price unit. If you need a supplied closure or other accessory, contact us before ordering.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We coordinate custom JGS1 quartz production for requirements involving dimensions, optical path length, sample volume, optical windows or Z Height, closures and connections, fabrication and tolerances. Send a dimensioned drawing or labelled sketch and identify the dimensions and tolerances that are critical to your application. Prototype batches typically involve 2–4 cells; the final quantity, feasibility, specifications, price and production time are confirmed in the project quotation. Discuss your requirements and mention part number C352CR.
Additional information
| Weight | 100 g |
|---|
You must be logged in to post a review.






Reviews
There are no reviews yet.