(C1002CC) Glass Rectangular Sample Cell, 100 mm Path, 60 mL
Original price was: $95.00.$86.00Current price is: $86.00.
C1002CC is a glass rectangular sample cell with a 100 mm optical path, open-top filling and 60 mL nominal capacity. It is intended for work within the stated 350–800 nm range and gives direct access to the sample during filling and cleaning. Sold as 1 cuvette per listed MQ sale.
Description
C1002CC is a glass rectangular sample cell for measurements within the stated 350–800 nm range. It combines a 100 mm optical path with an open-top body and 60 mL nominal capacity, making it a practical choice when your method needs a long light path and straightforward access to the sample chamber.
- Path Length
- 100 mm
- Sample Volume (Nominal)
- 60 mL
- Opening Configuration
- Open Top
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Rectangular Sample Cell |
| Measurement Mode | UV/Vis Spectroscopy |
| Path Length | 100 mm |
| Light Transmission Configuration | Two-Way Light |
| Wavelength Range — Lower Limit | 350 nm |
| Wavelength Range — Upper Limit | 800 nm |
| Sample Volume (Nominal) | 60 mL |
| External Dimensions | 104 × 20 × 40 mm |
| Cell Body Dimensions | 104 × 20 × 40 mm |
| External Dimensions Scope | Body Only |
| Material | Glass |
| Fabrication Method | Standard 80 |
| Opening Configuration | Open Top |
| Wall Thickness | 2 mm |
Choose this option
Choose C1002CC when your method is built around a 100 mm rectangular cell and you want direct top access for filling, level checking and cleaning. Its glass body and adhesive-bonded Standard 80 construction suit routine room-temperature water-based samples and buffers better than methods that require aggressive solvent cleaning or heated chemical exposure.
What makes this option different
- 100 mm optical path for methods that require a long rectangular transmission length.
- Open-top access for direct filling, pipetting and visual checking of the liquid level.
- 60 mL nominal capacity for larger sample volumes in one cell.
- 350–800 nm stated range for measurements carried out within that wavelength span.
Using this cell
Fill the cell from the top and make sure the liquid covers the beam region used by your instrument. Remove visible bubbles from the optical path area and keep the same orientation for blank and sample runs.
Handle the cell by the non-optical surfaces where possible. Because this is an open-top design, it is best used where direct access to the sample is acceptable and where splashing or evaporation will not disturb the measurement.
First-use check
- Inspect the optical faces for chips, scratches or handling residue.
- Rinse with a suitable cleaning medium for your process.
- Test the cell in the intended holder before preparing analytical samples.
- Run a blank and confirm that the beam passes cleanly through the intended faces.
Fit and optical alignment
The stated body dimensions are 104 × 20 × 40 mm, and they apply to the body only. Use them to check holder clearance and compartment space, especially for long-path arrangements where the overall body length matters.
Z Height is not stated for this option. If your holder or spectrometer depends on a defined beam-center height, check that point before purchase rather than assuming fit from body size alone.
Solvents and cleaning
This adhesive-bonded glass cuvette is listed as Standard 80. That makes it a practical choice for routine room-temperature water-based samples and buffers. A chemical compatibility range is not specified for this option, so discuss the exact liquid, concentration, temperature and contact time before using organic solvents, aggressive reagents or heated cleaning.
Keep hydrofluoric acid away from glass. Avoid hot strong alkalis and abrasive cleaners, and clean the optical faces gently with non-abrasive optical tissue.
Included with this option
Supplied as 1 cuvette.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We can review custom requirements related to dimensions, optical path length, sample volume, optical windows or Z Height, closures and fabrication. Send a dimensioned drawing or labelled sketch, together with your holder or instrument details, sample conditions and target quantity, through our contact page and reference C1002CC.