Site Navigation

(C052CS5) Glass Large-Window Cuvette, 5 mm Path, 7 mL

Weight100 g
SKU: C052CS5

Original price was: $80.00.Current price is: $72.00.

In Stock

C052CS5 is a glass large-window cuvette with a 5 mm optical path, an open top and a 7 mL nominal capacity. Its Two-Way Light layout supports straightforward transmission measurements, while the open sample chamber makes filling, rinsing and visual checking easy during routine manual work. Sold as 1 cuvette per price unit.

In Stock
Add to Wishlist
Add to Wishlist
SKU: C052CS5 Categories: , , Brand:
Shipping and order support
  • Worldwide delivery to door service, hassle free shipping
  • Contact us for quotation of bulk purchase discount
  • Custom design. Send us graphic drawing for solution
  • POs for Academics. Pay after delivery.
  • Availability and dispatch timing vary by item and quantity. Contact us to confirm timing for your order.

Description

C052CS5 is a glass large-window cuvette for transmission measurements with a 5 mm optical path and 7 mL nominal capacity. The open-top chamber gives direct access for pipetting, emptying and visual inspection, which is useful when you want simple manual handling rather than a closed or connected cell format. Its stated 350–800 nm wavelength range suits methods that work within that band.

The large-window body also gives you a broader cuvette format than a micro-volume cell. That makes it easier to handle at the bench, while the 5 mm path keeps the optical length fixed for methods built around that path.

Path Length
5 mm
Sample Volume (Nominal)
7 mL
Opening Configuration
Open Top

Selection Specifications

Product KindCuvette
Cell TypeLarge-Window Cuvette
Measurement ModeUV/Vis Spectroscopy
Path Length5 mm
Light Transmission ConfigurationTwo-Way Light
Wavelength Range — Lower Limit350 nm
Wavelength Range — Upper Limit800 nm
Sample Volume (Nominal)7 mL
External Dimensions40 × 9 × 40 mm
Body Height40 mm
Base Dimensions40 × 9 mm
MaterialGlass
Fabrication MethodStandard 80
Opening ConfigurationOpen Top

Choose this option

Choose C052CS5 when you need a glass cuvette that combines open-top sample access with a defined 5 mm transmission path. It is a practical choice for routine filling and rinsing by hand, especially when your method uses millilitre-scale sample loading and your instrument setup does not require a sealed cap, tubing connection or confirmed fixed beam height.

What makes this option different

  • Open-top access: you can fill, decant and inspect the sample directly from above, which suits manual pipetting and quick chamber rinsing between runs.
  • Two-Way Light layout: this cell is arranged for a straight transmission light path through the sample, so it fits methods based on opposing optical faces rather than side-access measurement geometry.
  • 5 mm path length: select this option when your method or holder is set up around a 5 mm optical path rather than a longer standard cell path.
  • 7 mL nominal capacity: the chamber is sized for a larger sample charge than a micro cell, which can be useful when your procedure is prepared at that scale.
  • Adhesive-bonded glass construction: this Standard 80 build is a sensible choice for routine room-temperature aqueous samples and buffer-based work, rather than methods that depend on aggressive organic exposure during use or cleaning.
  • Large-window body format: the broader 40 × 9 × 40 mm body is easier to place and remove by hand than a very small cuvette, but it still needs holder clearance to match.

Using this cell

Fill the cell from the top and make sure the sample level fully covers the beam during measurement. Because the chamber is open, it is easy to check for bubbles or suspended residue before you place the cell in the holder.

Use the same orientation for blank and sample if your procedure depends on consistent placement. Handle the cuvette by the non-optical surfaces where possible, and remember that the open-top format is for direct access rather than sealed, pressure-rated use.

First-use check

Before first use, inspect the optical faces for visible damage or residue, rinse with a suitable liquid for your method, and test the fit in the holder without forcing. After filling, confirm that the sample sits above the beam line and that the cell can be inserted and removed cleanly.

Fit and optical alignment

The body dimensions are 40 × 9 × 40 mm, with a 40 × 9 mm base. Check your holder width, depth and compartment clearance if the slot is closely sized, because this is a broad large-window body rather than a narrow micro-cell shape.

Z Height is not listed for this item. If your instrument uses a fixed beam position, check beam-height compatibility before ordering, since the outer dimensions and 5 mm path length do not by themselves establish optical center alignment.

Solvents and cleaning

This cuvette uses adhesive-bonded glass construction and maps to Standard 80 in the MQ fabrication glossary. In practice, this construction is typically selected for routine room-temperature aqueous samples and buffer solutions, where direct top filling and normal bench rinsing are part of the workflow.

Avoid treating it as a general-purpose choice for aggressive organic sample contact or organic cleaning solvents. Exact chemical limits are not listed for this SKU, so unusual chemicals, elevated temperatures or long contact times should be checked before use. Avoid HF-based cleaning and abrasive cleaning methods.

Included with this option

1 cuvette per listed price unit. If you need a supplied closure or other accessory, contact us before ordering.

Availability and ordering

Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.

Discuss a custom version

If this listed cell does not suit your holder or method, we can review a separate custom cuvette enquiry. Send a labelled drawing or sketch with the critical dimensions, optical path, holder or instrument details, sample conditions and target quantity through Discuss your requirements, and refer to part number C052CS5.

Additional information

Weight100 g

Reviews

There are no reviews yet.

Be the first to review “(C052CS5) Glass Large-Window Cuvette, 5 mm Path, 7 mL”

You may also like…

10%
(C052CA5) Glass Standard Cuvette, 5 mm Path, 1.75 mL

(C052CA5) Glass Standard Cuvette, 5 mm Path, 1.75 mL

30 g
In Stock
Original price was: $20.00.Current price is: $18.00.
Add to Wishlist
Add to Wishlist
8%
(C052CA6) Glass Standard Cuvette, 5 mm Path, 1.75 mL

(C052CA6) Glass Standard Cuvette, 5 mm Path, 1.75 mL

30 g
In Stock
Original price was: $38.00.Current price is: $35.00.
Add to Wishlist
Add to Wishlist
10%
(C052CC) Glass Large-Window Cuvette, 5 mm Path, 2 mL

(C052CC) Glass Large-Window Cuvette, 5 mm Path, 2 mL

30 g
In Stock
Original price was: $61.00.Current price is: $55.00.
Add to Wishlist
Add to Wishlist
10%
(C052CC1) Glass Large-Window Cuvette, 5 mm Path, 7 mL

(C052CC1) Glass Large-Window Cuvette, 5 mm Path, 7 mL

100 g
In Stock
Original price was: $80.00.Current price is: $72.00.
Add to Wishlist
Add to Wishlist
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • SKU
  • Rating
  • Price
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Weight
  • Dimensions
  • Additional information
Click outside to hide the comparison bar
Compare