(C052CA6) Glass Standard Cuvette, 5 mm Path, 1.75 mL
Original price was: $38.00.$35.00Current price is: $35.00.
C052CA6 is a glass standard cuvette for visible absorbance work with a 5 mm optical path, Two-Way Light transmission and 1.75 mL nominal capacity. The open-top cell is supplied as 1 cuvette per price unit and does not include a lid.
Description
C052CA6 is a glass standard cuvette for visible absorbance measurements from 350 to 2000 nm. It combines a 5 mm optical path with a 1.75 mL nominal capacity in an open-top, Two-Way Light format, making it suitable when you want direct top filling in a compact rectangular cell. This sale unit is 1 cuvette, and no lid is included.
- Path Length
- 5 mm
- Sample Volume (Nominal)
- 1.75 mL
- Opening Configuration
- Open Top
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Standard Cuvette |
| Measurement Mode | Visible Absorbance Spectroscopy |
| Path Length | 5 mm |
| Light Transmission Configuration | Two-Way Light |
| Wavelength Range — Lower Limit | 350 nm |
| Wavelength Range — Upper Limit | 2000 nm |
| Sample Volume (Nominal) | 1.75 mL |
| External Dimensions | 7.5 × 12.5 × 45 mm |
| Uncapped Cell Dimensions | 7.5 × 12.5 × 45 mm |
| External Dimensions Scope | Uncapped Cell |
| Material | Glass |
| Closure Type | Lid |
| Closure Included | No |
| Opening Configuration | Open Top |
Choose this option
Choose C052CA6 when your method calls for a 5 mm absorbance path and you prefer an open cell with no added cover to manage. The open top suits direct pipette filling, emptying and rinsing, while the supplier’s fused integrated construction wording points to a fixed cuvette body rather than a demountable sample chamber. That makes this option straightforward for routine bench use where simple access matters more than closure.
What makes this option different
- Open-top cell without a lid gives direct access for filling and rinsing, with no cover to remove or reinstall during routine bench work.
- 5 mm optical path suits absorbance methods built around this shorter transmission distance.
- Two-Way Light layout supports standard straight-through measurement through opposing optical faces.
- 1.75 mL nominal capacity provides a defined sample chamber size, but your working fill still needs to cover the beam in your instrument.
- Fused integrated construction indicates a fixed cell body rather than a user-assembled chamber, which is useful when you want ordinary cuvette handling and cleaning without extra assembly parts.
Using this cell
Fill the cell from the top and make sure the liquid fully covers the beam during measurement. The 1.75 mL figure is a nominal capacity for the cell, not a minimum working volume, so the required fill level still depends on your beam position and method setup.
Handle the cuvette by the non-optical faces where possible, keep the light path clean, and remove visible bubbles before measurement. Because no lid is included, plan this option around open-cell use rather than covered storage or transport after filling.
First-use check
Before first use, inspect the optical faces, top rim and corners for chips, residue or handling marks. Place the empty cell in your holder to confirm stable seating, then test with a blank to verify that your normal fill level covers the beam path as intended.
Fit and optical alignment
The stated 7.5 × 12.5 × 45 mm dimensions apply to the uncapped cell body. Use those dimensions to check holder seating and overhead clearance for filling and handling.
Z Height is not specified for this option. If your spectrometer, holder or sampling routine depends on a defined beam-center height, confirm that point before ordering rather than assuming alignment from the outside dimensions alone.
Solvents and cleaning
This glass cuvette is specified for visible absorbance use, but the exact chemical limits of the assembly are not established here. If your samples or cleaning routine involve aggressive chemicals, prolonged contact, elevated temperature or specific organic solvents, check suitability for your exact conditions before use.
For routine cleaning, use methods appropriate to your sample and avoid abrasive tools or cleaners that could mark the optical faces. For general background on cuvette construction and selection, see Fabrication Method of Cuvettes.
Included with this option
1 cuvette per listed price unit. Supplied without a lid.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
If you need the same general cell style with a different path length, material or related geometry, you can contact us about a custom version. Custom designs are quoted separately from this listed specification.
Additional information
| Weight | 30 g |
|---|
You must be logged in to post a review.








Reviews
There are no reviews yet.