(C052CA4) Glass Standard Cuvette, 5 mm Path, 1.75 mL
Original price was: $11.00.$10.00Current price is: $10.00.
C052CA4 is a glass standard cuvette for visible absorbance work with a 5 mm optical path, Two-Way Light transmission and 1.75 mL nominal capacity. Its open-top format gives direct access for filling and rinsing, and this sale unit includes 1 cuvette with a closure.
Description
C052CA4 is a glass standard cuvette for visible absorbance measurements from 350 to 2000 nm. It combines a 5 mm optical path with a 1.75 mL nominal capacity in an open-top body, giving straightforward top access for filling, blanking and rinsing while keeping the familiar rectangular cuvette format. This sale unit is 1 cuvette, and a closure is included.
- Path Length
- 5 mm
- Sample Volume (Nominal)
- 1.75 mL
- Opening Configuration
- Open Top
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Standard Cuvette |
| Measurement Mode | Visible Absorbance Spectroscopy |
| Path Length | 5 mm |
| Light Transmission Configuration | Two-Way Light |
| Wavelength Range — Lower Limit | 350 nm |
| Wavelength Range — Upper Limit | 2000 nm |
| Sample Volume (Nominal) | 1.75 mL |
| External Dimensions | 7.5 × 12.5 × 45 mm |
| Uncapped Cell Dimensions | 7.5 × 12.5 × 45 mm |
| External Dimensions Scope | Uncapped Cell |
| Material | Glass |
| Closure Type | Lid |
| Closure Included | Yes |
| Opening Configuration | Open Top |
Choose this option
Choose C052CA4 when your method calls for a 5 mm absorbance path in a compact glass cell and you want direct access from above instead of a flow connection or demountable plate assembly. The nominal 1.75 mL capacity suits routine bench filling, and the included closure can cover the opening after filling. The cell uses a fused integrated construction in the supplier’s wording, which points to a built one-piece-style cell body rather than a user-assembled sample chamber, so routine handling and cleaning stay in the familiar format of a fixed rectangular cuvette.
What makes this option different
- Open-top access with closure included lets you fill and empty the cell directly from above, then cover the opening for routine handling.
- 5 mm optical path suits methods set up for this shorter absorbance distance without moving to a larger cell format.
- Two-Way Light layout supports straight-through transmission measurement through opposing optical faces for ordinary absorbance work.
- 1.75 mL nominal capacity gives a practical sample region for routine preparation, but your actual fill still needs to cover the beam in your instrument.
- Fused integrated construction means the cell body is supplied as a fixed cuvette rather than a demountable assembly, which is helpful when you want ordinary filling and cleaning without assembling sample-contact parts.
Using this cell
Fill the cell from the top and make sure the liquid level fully covers the beam during measurement. Use the same orientation for blank and sample when your procedure depends on consistent positioning, and remove visible bubbles from the light path before reading.
The included closure is useful for covered bench handling after filling, but this remains an open-top cuvette rather than a stated sealed or pressure-rated assembly. If your procedure involves transport after filling, agitation, extended standing time or any need for a tight seal, check whether this geometry is appropriate for your use.
First-use check
Inspect the optical faces and rim for chips, residue or scratches before first use. Rinse with a cleaning method suitable for your sample and the complete cell assembly, then run a blank to confirm clean handling, correct seating and full beam coverage at your normal fill level.
Fit and optical alignment
The recorded body dimensions for the uncapped cell are 7.5 × 12.5 × 45 mm. Use those uncapped dimensions to check holder seating and surrounding clearance, and allow extra space above the cell for the closure because the installed height with the closure in place is not stated here.
Z Height is not stated for this option. If your instrument or holder depends on a defined beam-center height, check that point before ordering rather than relying on the outside dimensions alone.
Solvents and cleaning
This glass cuvette is intended for visible-light analytical use, but the exact chemical limits of this selected assembly are not established here. If your samples or cleaning routine involve organic solvents, strong acids, strong alkalis, elevated temperature or long contact times, check suitability for the full cell-and-closure assembly before use.
For routine cleaning, avoid abrasive materials that can mark the optical faces. For general background on cuvette construction and selection, see Fabrication Method of Cuvettes.
Included with this option
1 cuvette per listed price unit. A closure is included.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
If you need the same general cell style with a different path length, material or related geometry, you can contact us about a custom version. Custom designs are quoted separately from this listed specification.
Additional information
| Weight | 30 g |
|---|
You must be logged in to post a review.








Reviews
There are no reviews yet.