(C104CE4) Quartz Micro Cuvette, 10 mm / 1 mm (dual path) Path, 350 µL
Original price was: $323.00.$291.00Current price is: $291.00.
C104CE4 is a JGS1 quartz micro cuvette for fluorescence spectroscopy, combining a 10 mm main path with a 1 mm secondary path in a Four-Way Light format. Its 350 µL nominal capacity suits limited-volume measurements where side optical access and a narrow sample region both matter. Supplied as 1 cuvette with an included closure.
Description
C104CE4 is a JGS1 quartz micro cuvette for fluorescence spectroscopy when you need four-side optical access in a compact body. It combines a 10 mm main path, a 1 mm secondary path and a 350 µL nominal capacity, so you can work with a small sample region while keeping the optical layout of this dual-path format in view. The stated wavelength range for this option is 200–2500 nm.
- Path Length
- 10 mm / 1 mm (dual path)
- Sample Volume (Nominal)
- 350 µL
- Closure Type
- Lid
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Micro Cuvette |
| Measurement Mode | Fluorescence Spectroscopy |
| Pack Quantity | 1 Piece |
| Path Length | 10 mm / 1 mm (dual path) |
| Light Transmission Configuration | Four-Way Light |
| Optical Window Dimensions | 1 mm |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 350 µL |
| External Dimensions | 12.5 × 12.5 × 45 mm |
| Uncapped Cell Dimensions | 12.5 × 12.5 × 45 mm |
| External Dimensions Scope | Uncapped Cell |
| Material | Quartz |
| Material Grade | JGS1 |
| Closure Type | Lid |
| Closure Included | Yes |
| Fabrication Method | Molded 83 |
| Detection Channel Width | 1 mm |
Choose this option
Choose C104CE4 when your method needs a micro cuvette with side access on four transmitting faces and a defined 10 mm / 1 mm geometry. The narrow 1 mm sample-region width is relevant when beam placement and sample coverage need closer attention than in a wider chamber, and the 350 µL nominal capacity keeps this model in a small-volume format rather than a larger general-purpose cell.
What makes this option different
- Four-Way Light access: side optical access on four faces supports fluorescence setups that use more than a simple straight-through layout.
- Dual-path format: a 10 mm main path and 1 mm secondary path are built into the same cuvette body.
- Narrow sample region: the stated 1 mm channel width is useful to consider when checking beam placement and fill coverage.
- Micro-volume body: 350 µL nominal capacity suits small prepared samples without moving to a full-size cuvette format.
- Included closure: supplied with a closure, while the listed 12.5 × 12.5 × 45 mm dimensions apply to the uncapped cell body.
- Quartz for the stated range: JGS1 quartz with a specified 200–2500 nm range for this option.
Using this cell
Fill the cell so the illuminated sample region is fully covered during measurement. In this geometry, bubbles or droplets near the optical faces can interfere with alignment more easily than in a broader chamber, so it helps to load the sample carefully and keep the same orientation for blank and sample runs.
The nominal 350 µL figure describes the model capacity, not a minimum working volume. If your method runs with very low fill levels, verify coverage of the actual beam position before routine use.
First-use check
Before first use, inspect the optical faces and closure contact area for dust, residue or small chips. Place the cuvette in the intended holder, confirm stable seating, and run a blank to make sure the beam passes cleanly through the intended sample region.
Fit and optical alignment
The stated body dimensions are 12.5 × 12.5 × 45 mm for the uncapped cell. Use those dimensions for holder seating, and allow extra overhead space for the installed closure because the assembled height is not stated here.
Z Height is not specified for this SKU, so holder fit and beam alignment should be checked from your instrument geometry rather than assumed from the outer body size alone. This is especially relevant when the 1 mm sample region must be positioned reliably within the beam.
Solvents and cleaning
This cuvette is listed under Molded 83, with the exact source describing the joining method as optical contact. For customer selection, this fabrication category is commonly chosen for methods that may involve organic-solvent handling, but the exact chemical limits for this specific assembled cuvette are not established here.
Choose cleaning and sample-contact conditions for the full assembly, including the closure. Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaning, and wipe the optical faces with non-abrasive optical tissue.
Included with this option
Supplied as 1 quartz micro cuvette with an included closure.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We can review custom JGS1 quartz versions related to dimensions, optical path length, nominal volume, optical windows or Z Height, closures and fabrication or tolerance requirements. Send a labelled sketch or drawing together with your holder or instrument details, key dimensions, sample conditions and target quantity. Prototype batches typically involve 2–4 cells; final feasibility, specifications, price and production time are confirmed in quotation. Discuss your requirements and mention part number C104CE4.
Additional information
| Weight | 30 g |
|---|
You must be logged in to post a review.






Reviews
There are no reviews yet.