(C104CE11) Quartz Micro Cuvette, 10 mm / 2 mm (dual path) Path, 700 µL
Original price was: $323.00.$291.00Current price is: $291.00.
C104CE11 is a JGS1 quartz micro cuvette for fluorescence spectroscopy with a 10 mm main path, 2 mm secondary path and Four-Way Light access. Its 700 µL nominal capacity and supplied lid suit compact fluorescence setups built around this dual-path geometry. Sold as 1 cuvette.
Description
C104CE11 is a JGS1 quartz micro cuvette for fluorescence spectroscopy, combining a 10 mm main path with a 2 mm secondary path in a compact Four-Way Light body. The 700 µL nominal capacity and narrow sample region make it suitable when you need this specific fluorescence cell geometry rather than a larger square cuvette. This option is sold as one cuvette and includes a lid.
- Path Length
- 10 mm / 2 mm (dual path)
- Sample Volume (Nominal)
- 700 µL
- Closure Type
- Lid
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Micro Cuvette |
| Measurement Mode | Fluorescence Spectroscopy |
| Pack Quantity | 1 Piece |
| Path Length | 10 mm / 2 mm (dual path) |
| Light Transmission Configuration | Four-Way Light |
| Optical Window Dimensions | 2 mm |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 700 µL |
| External Dimensions | 12.5 × 12.5 × 45 mm |
| Uncapped Cell Dimensions | 12.5 × 12.5 × 45 mm |
| External Dimensions Scope | Uncapped Cell |
| Material | Quartz |
| Material Grade | JGS1 |
| Closure Type | Lid |
| Closure Included | Yes |
| Fabrication Method | Molded 83 |
| Detection Channel Width | 2 mm |
Choose this option
Choose C104CE11 when your method is built around a 10 mm / 2 mm dual-path layout and side optical access around the sample region. The supplied lid helps with routine handling after filling, while the compact uncapped body can be useful where holder space is limited, provided your beam position and clearance match the cell.
What makes this option different
- 10 mm main path with 2 mm secondary path for methods that use this exact dual-path arrangement.
- Four-Way Light geometry for fluorescence setups that use optical access from more than one side.
- 700 µL nominal capacity in a compact micro cuvette format.
- Lid included for routine covered handling after filling.
Using this cell
Fill the cuvette so the illuminated sample region is fully covered, then seat the lid gently on clean contact surfaces. Keep bubbles, residue and fingerprints away from the optical faces, and use the same orientation for blank and sample so the optical layout stays consistent between runs.
The lid is useful for normal handling, but it should not be treated as a pressure-rated or leak-tight closure for inversion, transport or closed-loop flow use. The 700 µL value is nominal capacity, not a minimum working volume, so practical fill level should be set by the beam position in your own instrument.
First-use check
- Inspect the cuvette and lid contact area for chips, dust or residue.
- Rinse with a cleaning liquid appropriate to your method and dry the outer optical faces gently.
- Run a blank to confirm seating, beam alignment and practical fill level before measuring samples.
Fit and optical alignment
The stated external dimensions apply to the uncapped cell body: 12.5 × 12.5 × 45 mm. If your fluorometer or holder has limited vertical space, allow additional clearance for the fitted lid because the installed overall height is not stated here.
Z Height is not stated for this option. If your setup requires a defined beam-center height, please check holder datum and beam position before ordering rather than assuming fit from body size alone.
Solvents and cleaning
This cuvette uses Molded 83 fabrication with an optical-contact supplier construction option. This fabrication is often selected for methods that may involve organic solvents or temperature-controlled work, but the exact chemical limits for this SKU are not stated here.
Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaning, and check the suitability of your sample and cleaning liquids for the full cuvette-and-lid assembly before use.
Included with this option
One cuvette. Lid included.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We coordinate custom JGS1 quartz production for requirements involving dimensions, optical path length, sample volume, optical windows or Z Height, closures and connections, fabrication and tolerances. Send a dimensioned drawing or labelled sketch and identify the dimensions and tolerances that are critical to your application.
Prototype batches typically involve 2–4 cells; final feasibility, specifications, quantity, price and production time are confirmed in quotation. Discuss your requirements and quote part number C104CE11.
Additional information
| Weight | 30 g |
|---|
You must be logged in to post a review.






Reviews
There are no reviews yet.