(C014TE1) Quartz Micro Cuvette, 10 mm / 1 mm (dual path) Path, 350 µL, Pack of 2
Original price was: $949.00.$855.00Current price is: $855.00.
C014TE1 is a JGS1 quartz micro cuvette for fluorescence spectroscopy with a 10 mm main path, a 1 mm secondary path and a Four-Way Light layout. Its 350 µL nominal capacity suits small-volume handling in a compact square-body format. Supplied as a pack of 2, with caps included.
Description
C014TE1 is a JGS1 quartz micro cuvette for fluorescence spectroscopy with a 10 mm main path, a 1 mm secondary path and a Four-Way Light layout. The 350 µL nominal capacity keeps the cell in a compact micro format, while the square base fits familiar cuvette-holder footprints. This offer is supplied as a pack of 2, with caps included.
The physical cell geometry matches the same compact format used for this style: a 12.5 × 12.5 × 45 mm rectangular body, 56 mm uncapped overall height and 60 mm overall height with cap. That makes it easier to check seating clearance and top clearance separately when you plan the installation.
- Path Length
- 10 mm / 1 mm (dual path)
- Sample Volume (Nominal)
- 350 µL
- Closure Type
- Screw Cap
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Micro Cuvette |
| Measurement Mode | Fluorescence Spectroscopy |
| Pack Quantity | Pack of 2 |
| Path Length | 10 mm / 1 mm (dual path) |
| Light Transmission Configuration | Four-Way Light |
| Optical Window Dimensions | 1 mm |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 350 µL |
| External Dimensions | 12.5 × 12.5 × 56 mm |
| Cell Body Dimensions | 12.5 × 12.5 × 45 mm |
| Uncapped Cell Dimensions | 12.5 × 12.5 × 56 mm |
| Overall Height without Closure | 56 mm |
| External Dimensions Scope | Uncapped Cell |
| Body Height | 45 mm |
| Overall Height with Closure | 60 mm |
| Base Dimensions | 12.5 × 12.5 mm |
| Material | Quartz |
| Material Grade | JGS1 |
| Closure Type | Screw Cap |
| Closure Included | Yes |
| Fabrication Method | Molded 83 |
| Detection Channel Width | 1 mm |
Choose this option
Choose C014TE1 when you need the same 10 mm / 1 mm dual-path fluorescence cell geometry as the single-piece option, but want a two-cuvette sale pack. The Four-Way Light layout supports side optical access around the sample region, and the separate body, uncapped and capped heights help when clearance above the holder matters.
What makes this option different
- 10 mm / 1 mm dual-path layout for methods that use both the main and narrow secondary optical directions.
- Four-Way Light configuration for optical access from four sides around the sample region.
- 350 µL nominal capacity in a compact square-body micro-cuvette format.
- Pack of 2 with caps included for the priced sale unit.
Using this cell
Fill each cell so the illuminated sample region remains fully covered and free of bubbles during measurement. Keep the same orientation for blank and sample runs, especially if your method depends on the 1 mm optical direction as well as the 10 mm path.
The 350 µL figure is the nominal capacity of each cell, not a minimum working volume. Fit the cap after filling if needed, but do not treat the closure as a pressure or closed-loop rating.
First-use check
Inspect both cuvettes for chips, residue or transport marks before use. Rinse with a suitable liquid for your method, seat each cell squarely in the holder, and run a blank in the same orientation you plan to use for sample measurements.
Fit and optical alignment
The square base is 12.5 × 12.5 mm for holder seating. For height planning, distinguish between the 45 mm rectangular body, the 56 mm uncapped overall height and the 60 mm overall height with the cap in place.
Z Height is not established for this item. If your instrument depends on a fixed beam position, check the actual beam height and clearance in your own holder rather than assuming fit from the external shape alone.
Solvents and cleaning
This cuvette uses Molded 83 quartz construction. Molded 83 is commonly chosen when organic-solvent methods or temperature-controlled work are part of the application, but actual sample and cleaning liquids still need to suit the complete assembly, including the cap if it will contact the liquid.
Do not use hydrofluoric acid with quartz. Avoid hot strong alkalis and abrasive cleaning. Clean the optical faces gently with a non-abrasive, lint-free material suitable for laboratory optical surfaces.
Included with this option
Sold as a pack of 2 micro cuvettes. Closure is included.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We coordinate custom JGS1 quartz production for requirements involving dimensions, optical path length, sample volume, optical windows or Z Height, closures and fabrication. Send a dimensioned drawing or labelled sketch together with your holder or instrument details, critical dimensions, sample chemistry and target quantity. Discuss your requirements and reference C014TE1.
Additional information
| Weight | 30 g |
|---|
You must be logged in to post a review.







Reviews
There are no reviews yet.