C104CA3 is a JGS1 quartz fluorescence cuvette with a dual-path layout: 10 mm on one optical axis and 25 mm on the other in one Four-Way Light body. Its open-top format and 9 mL nominal capacity suit fluorescence work that needs direct filling and a larger sample chamber than a compact square cell. Supplied as a pack of 2 cuvettes.
Description
C104CA3 is a JGS1 quartz fluorescence cuvette for setups that use two labelled optical paths in one cell body. It combines a 10 mm path on one axis with a 25 mm path on the other, in a Four-Way Light format with direct top access to the sample chamber. The 9 mL nominal capacity and rectangular uncapped body make it a practical choice when your method needs more sample space and a specific fluorescence viewing geometry.
- Path Length
- 10 mm / 25 mm (dual path)
- Sample Volume (Nominal)
- 9 mL
- Opening Configuration
- Open Top
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Fluorescence Cuvette |
| Measurement Mode | Fluorescence Spectroscopy |
| Pack Quantity | Pack of 2 |
| Path Length | 10 mm / 25 mm (dual path) |
| Light Transmission Configuration | Four-Way Light |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 9 mL |
| External Dimensions | 12.5 × 27.5 × 45 mm |
| Uncapped Cell Dimensions | 12.5 × 27.5 × 45 mm |
| External Dimensions Scope | Uncapped Cell |
| Material | Quartz |
| Material Grade | JGS1 |
| Closure Type | Lid |
| Closure Included | Yes |
| Opening Configuration | Open Top |
Choose this option
Choose C104CA3 when your method is built around a Four-Way Light fluorescence cell and you need the 10 mm / 25 mm dual-path arrangement rather than a single-path square cuvette. The open top makes filling, rinsing and visual checking straightforward, and the wider body is useful when you want a larger nominal chamber volume in the same cell.
What makes this option different
- Two labelled optical paths in one cell: 10 mm on one axis and 25 mm on the other.
- Four-Way Light body for fluorescence measurements that use optical access from multiple sides.
- 9 mL nominal capacity in a rectangular format rather than a compact 10 × 10 mm square body.
- Sold as 2 physical cuvettes per price unit.
Using this cell
Fill the cell from the open top and keep the same face orientation for blank and sample runs. In fluorescence work, place the cuvette so the intended excitation and observation directions use the correct optical axis, then check that the beam area is free of bubbles, droplets and dried residue.
The 9 mL figure is the nominal cell capacity, not a minimum working volume. If your method uses a low fill level or depends on a defined beam height, check that the liquid level in use will fully cover the measurement region.
First-use check
- Inspect the optical faces and rim for chips, scratches or handling residue.
- Rinse the wetted surfaces with a cleaning liquid suitable for your method.
- Place the cell in the holder and confirm the intended 10 mm and 25 mm orientation before measurement.
- Run a blank with the cell filled to a level that covers the measurement zone.
Fit and optical alignment
The listed external dimensions are for the uncapped cell body: 12.5 × 27.5 × 45 mm. Use those dimensions to review holder seating, side clearance and access around the longer body shape, especially if your compartment or fixture is designed around a narrower fluorescence cell.
Z Height is not established for this SKU, so overall body height should not be used as a substitute for beam-center fit. A closure is stated as included, but the body dimensions above do not include any installed closure, so allow extra top clearance where needed.
Solvents and cleaning
This cuvette is specified in quartz for use across the stated 200–2500 nm range. For general background on construction approaches, see Compare fabrication options. Chemical limits for this exact SKU are not established here, so match both sample liquids and cleaning steps to the full wetted assembly before use.
Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaning methods. Clean the optical faces gently with non-abrasive optical tissue and do not allow residues to dry on the windows after use.
Included with this option
Price is for 2 cuvettes, supplied as this listed C104CA3 option.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We coordinate custom JGS1 quartz cuvette projects for changes involving dimensions, optical path length, sample volume, optical windows, Z Height, closures, connections and tolerance requirements. Send a dimensioned drawing or labelled sketch together with holder details, wavelength range, sample conditions and target quantity. Discuss your requirements and mention part number C104CA3.
Additional information
| Weight | 100 g |
|---|
You must be logged in to post a review.







Reviews
There are no reviews yet.