(C305CA) Quartz Fluorescence Cuvette, 30 mm / 10 mm (dual path) Path, 10.5 mL
Original price was: $156.00.$141.00Current price is: $141.00.
C305CA is a JGS1 quartz fluorescence cuvette with a 30 mm primary path, a 10 mm secondary path and 10.5 mL nominal capacity in one rectangular cell body. The covered opening uses a PTFE lid, which suits methods that want direct top access for filling and a lid in place during routine handling or measurement. Sold as 1 cuvette per price unit.
Description
C305CA is a JGS1 quartz fluorescence cuvette for methods that use a 30 mm optical path in a rectangular cell body. It also provides a 10 mm secondary path, giving you a second measurement orientation in the same cuvette, which is useful when your fluorescence setup or handling routine needs the sample presented in a different direction. The 10.5 mL nominal capacity and PTFE lid make it a practical choice when you want top filling, covered handling and a longer-path quartz cell in one format.
- Path Length
- 30 mm / 10 mm (dual path)
- Sample Volume (Nominal)
- 10.5 mL
- Closure Type
- Lid
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Fluorescence Cuvette |
| Measurement Mode | Fluorescence Spectroscopy |
| Pack Quantity | 1 Piece |
| Path Length | 30 mm / 10 mm (dual path) |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 10.5 mL |
| External Dimensions | 12.5 × 32.5 × 45 mm |
| Uncapped Cell Dimensions | 12.5 × 32.5 × 45 mm |
| External Dimensions Scope | Uncapped Cell |
| Material | Quartz |
| Material Grade | JGS1 |
| Closure Type | Lid |
| Closure Material | PTFE |
| Closure Included | Yes |
Choose this option
Choose C305CA when your method is built around a 30 mm path but you also want a defined 10 mm orientation in the same cell body. That combination helps when the sample needs to be filled from the top, checked visually before measurement and then kept covered with the PTFE lid during normal bench use. The fused integrated construction term used by the supplier identifies this exact build style for the cell body; for selection, treat it as this product’s stated construction rather than as a claim about universal solvent use, certified tolerance or special instrument compatibility.
What makes this option different
- 30 mm primary path for fluorescence methods that require a longer optical distance than a standard 10 mm measurement direction.
- 10 mm secondary path in the same cell body, so you can orient the cuvette to suit the measurement direction used by your setup.
- PTFE lid over a top opening for direct filling and sample access before covered handling or measurement.
- 10.5 mL nominal capacity for methods that use a larger sample volume in a rectangular fluorescence cuvette format.
- Fused integrated construction as the supplier’s stated construction term for this exact cuvette body.
- 12.5 × 32.5 × 45 mm uncapped body for checking holder fit and top clearance separately from the lid.
Using this cell
Fill from the top opening and make sure the liquid covers the optical region used by your method. The PTFE lid acts as a cover rather than a threaded connection or removable plate assembly, so it is well suited to routine bench handling where you want direct access first and a covered sample afterward.
Use the same orientation for blank, standards and samples throughout the method. In practice, the 30 mm direction and the 10 mm direction are not interchangeable labels: they represent two different optical paths in the same rectangular body, so consistent positioning matters when your fluorescence setup is arranged around one specific viewing direction.
First-use check
Inspect the cuvette and lid on arrival, rinse according to your laboratory procedure, and place the empty cell in the holder before preparing a full sample. Then confirm that the beam passes through the intended faces in the orientation your method uses.
Fit and optical alignment
The listed 12.5 × 32.5 × 45 mm dimensions apply to the uncapped cell body. Check holder width, depth and top clearance separately if the lid remains in place during measurement, because the uncapped outline does not define installed clearance with the lid on.
Z Height is not specified for this item. If your instrument requires a defined beam-center height, confirm that point before ordering rather than assuming alignment from the external body shape.
Solvents and cleaning
The cell body is quartz and the supplied lid is PTFE. For background on cuvette construction approaches, see Compare fabrication methods.
Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaning. Specific chemical limits for this exact configuration are not established here, so if your sample or cleaning routine involves demanding solvent, concentration, temperature or contact-time conditions, check suitability for the complete assembly before use.
Included with this option
One C305CA quartz fluorescence cuvette with PTFE lid.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We coordinate custom JGS1 quartz production for requirements involving dimensions, optical path length, sample volume, optical windows or Z Height, closures and connections, fabrication and tolerances. Send a dimensioned drawing or labelled sketch together with your holder or instrument details, critical dimensions, sample conditions and target quantity. Discuss your requirements and quote part number C305CA.
Additional information
| Weight | 100 g |
|---|
You must be logged in to post a review.






Reviews