(C305CA1) Quartz Fluorescence Cuvette, 30 mm / 10 mm (dual path) Path, 10.5 mL, Pack of 2
Original price was: $312.00.$281.00Current price is: $281.00.
C305CA1 is a JGS1 quartz fluorescence cuvette with a 30 mm primary path, a 10 mm secondary path and 10.5 mL nominal capacity. Its top-access body is supplied with PTFE lids for covered handling after filling. Sold as a pack of 2 cuvettes.
Description
C305CA1 is a JGS1 quartz fluorescence cuvette built for methods that use a 30 mm optical path in a rectangular cell. This option also provides a 10 mm secondary path in the alternate orientation, so one cell geometry can support two beam directions within the same body. With a 10.5 mL nominal capacity and supplied PTFE lids, it suits top filling followed by covered handling, and it is sold as a pack of 2 cuvettes.
- Path Length
- 30 mm / 10 mm (dual path)
- Sample Volume (Nominal)
- 10.5 mL
- Closure Type
- Lid
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Fluorescence Cuvette |
| Measurement Mode | Fluorescence Spectroscopy |
| Pack Quantity | Pack of 2 |
| Path Length | 30 mm / 10 mm (dual path) |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 10.5 mL |
| External Dimensions | 12.5 × 32.5 × 45 mm |
| Uncapped Cell Dimensions | 12.5 × 32.5 × 45 mm |
| External Dimensions Scope | Uncapped Cell |
| Material | Quartz |
| Material Grade | JGS1 |
| Closure Type | Lid |
| Closure Material | PTFE |
| Closure Included | Yes |
Choose this option
Choose C305CA1 when your method needs the longer 30 mm fluorescence path but you also want the practical option of using the same cell in its 10 mm orientation. That layout can be useful when your procedure, holder setup or check measurements call for a different beam direction without changing to a different cell format. The 10.5 mL nominal capacity gives a larger sample region than a very small rectangular cell, and the included PTFE lids let you cover the top opening after loading.
What makes this option different
- 30 mm primary path for fluorescence work that is arranged around a longer rectangular optical route.
- 10 mm secondary path so the same cuvette body can be used in a second orientation when your method calls for that geometry.
- 10.5 mL nominal capacity for methods that need a larger filled sample region in this cell format.
- Top-access design with PTFE lids for direct filling from above, then covered handling once the sample is in place.
- Fused integrated construction as the supplier’s stated construction term for this exact cuvette.
- Uncapped body size of 12.5 × 32.5 × 45 mm for checking holder space and top clearance before ordering.
- Pack of 2 cuvettes for this priced sales unit.
Using this cell
Load the sample from the top opening, then place the PTFE lid when your procedure benefits from covered handling during transfer or measurement. Keep the cuvette orientation consistent, because the body offers both a 30 mm primary path and a 10 mm secondary path depending on how the cell is placed in the beam.
The nominal capacity describes the cell’s stated fill volume, not a minimum working volume. Before measurement, make sure the liquid level fully covers the optical region your method uses, and check for bubbles or droplets on the optical faces.
First-use check
Inspect both cuvettes and the supplied lids on arrival, then rinse according to your laboratory procedure before first measurement. Test the cell in your holder with the intended orientation and confirm that the beam passes through the faces used for your 30 mm or 10 mm setup.
Fit and optical alignment
The listed 12.5 × 32.5 × 45 mm dimensions apply to the uncapped cell body. If your holder, compartment lid or sampling arrangement has limited overhead space, allow separately for the added clearance needed when the PTFE lid is in place.
Z Height is not specified for this item. If your instrument depends on a defined beam-center height, confirm that requirement before ordering rather than relying on the rectangular outline alone.
Solvents and cleaning
The cell body is quartz and the supplied lids are PTFE. The supplier describes this cuvette as having fused integrated construction; for general construction background across MQ cuvette types, see Compare fabrication methods.
Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaning, and clean the optical faces gently with non-abrasive optical tissue. Suitability for your actual sample chemistry, concentration, temperature and contact time should be checked for the complete wetted setup.
Included with this option
Two C305CA1 quartz fluorescence cuvettes with PTFE lids.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We coordinate custom JGS1 quartz projects for requirements involving dimensions, optical path length, sample volume, optical windows or Z Height, closures and connections, construction approach and tolerances. Send a dimensioned drawing or labelled sketch, plus your holder or instrument details, critical dimensions, sample conditions and target quantity. Prototype batches typically involve 2–4 cells; feasibility, final specifications, price and production time are confirmed in the project quotation. Discuss your requirements and quote part number C305CA1.
Additional information
| Weight | 100 g |
|---|
You must be logged in to post a review.







Reviews
There are no reviews yet.