(C104CA2) Quartz Fluorescence Cuvette, 10 mm / 25 mm (dual path) Path, 9 mL
Original price was: $147.00.$133.00Current price is: $133.00.
C104CA2 is a JGS1 quartz fluorescence cuvette with two measurement directions in one body: 10 mm and 25 mm. Its Four-Way Light layout and open-top access make it practical for fluorescence work that needs side optical access and direct filling. Supplied as 1 cuvette, with closure included.
Description
C104CA2 is a JGS1 quartz fluorescence cuvette built for workflows that need two established path lengths in one cell body. You can use the 10 mm or 25 mm measurement direction by changing the cell orientation, while the open top gives direct access for filling, checking the sample and cleaning the chamber. This cell is specified for fluorescence spectroscopy and has a 9 mL nominal capacity.
The body uses a fused integrated construction, which makes the dual-path fluorescence geometry part of one assembled cuvette rather than a separate add-on arrangement. In practice, that matters when you want one cell format that can be placed in different orientations for different optical paths while keeping the same sample chamber and handling approach.
- Path Length
- 10 mm / 25 mm (dual path)
- Sample Volume (Nominal)
- 9 mL
- Opening Configuration
- Open Top
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Fluorescence Cuvette |
| Measurement Mode | Fluorescence Spectroscopy |
| Pack Quantity | 1 Piece |
| Path Length | 10 mm / 25 mm (dual path) |
| Light Transmission Configuration | Four-Way Light |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 9 mL |
| External Dimensions | 12.5 × 27.5 × 45 mm |
| Uncapped Cell Dimensions | 12.5 × 27.5 × 45 mm |
| External Dimensions Scope | Uncapped Cell |
| Material | Quartz |
| Material Grade | JGS1 |
| Closure Type | Lid |
| Closure Included | Yes |
| Opening Configuration | Open Top |
Choose this option
Choose C104CA2 when your method benefits from switching between 10 mm and 25 mm optical paths without changing to a different cuvette. It suits fluorescence setups that use side optical access around the sample region and need direct top filling rather than a permanently closed or piped cell. The included closure helps cover the open-top body during routine handling, but this page does not treat it as a pressure-rated or leak-tight feature.
What makes this option different
- Two optical path directions, 10 mm and 25 mm, are built into one cuvette body, so you can change path length by changing orientation instead of changing cells.
- Four-Way Light geometry provides optical access from multiple side directions around the sample region, which is useful for fluorescence measurement layouts that need more than a single straight-through direction.
- The open-top design gives direct access for filling, sample inspection and chamber rinsing.
- Its fused integrated construction keeps this dual-path arrangement as one assembled quartz body for handling and placement.
- The 9 mL nominal capacity suits methods that use a larger filled sample region than a micro-volume format.
- Supplied as 1 cuvette, with closure included.
Using this cell
Fill the cuvette from the top, then place it in the holder in the orientation that matches the optical path you want to use for that run. Keep blank and sample measurements in the same orientation so the chosen path direction stays consistent through the series.
If your workflow uses both path lengths, it is worth setting a simple handling routine for rotation and placement before you start. Check the sample region before measurement and remove visible bubbles, droplets or residue from the optical faces.
First-use check
- Inspect the cell body, optical faces and closure for dust, fingerprints or shipping residue.
- Place the empty cuvette in your holder and confirm stable seating in each intended measurement orientation.
- Run a blank in the chosen orientation before measuring samples.
Fit and optical alignment
The stated 12.5 × 27.5 × 45 mm dimensions apply to the uncapped cell body. Use those dimensions to check holder width, seating space and side clearance around the installed cell body.
Z Height is not stated for this SKU, so beam-center alignment should be checked in your own holder if your instrument depends on a defined beam height. The listed body dimensions are uncapped dimensions, and the installed height with the closure is not stated here, so verify top clearance where vertical space above the holder is limited.
Solvents and cleaning
This quartz cuvette is specified for fluorescence spectroscopy across 200–2500 nm. Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaning, and clean the optical faces gently with suitable non-abrasive optical tissue.
Detailed chemical compatibility for this exact SKU is not established here, so check routine suitability against your sample, rinse solvent and cleaning conditions. For fabrication background, see MQ Cuvette Fabrication Glossary.
Included with this option
One cuvette with closure included.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We coordinate custom JGS1 quartz versions for requirements involving dimensions, optical path length, optical access, closures and tolerances. Send a dimensioned drawing or labelled sketch together with holder or instrument details, sample conditions and target quantity. Discuss your requirements and quote part number C104CA2.