(C104CE26) Quartz Micro Cuvette, 10 mm Path, 1.75 mL
Original price was: $323.00.$291.00Current price is: $291.00.
C104CE26 is a quartz micro cuvette for fluorescence spectroscopy with a 10 mm optical path, Four-Way Light access and a 5 mm sample channel. Its 1.75 mL nominal capacity gives this version the widest recorded sample region in this group while keeping the same compact uncapped body format. Sold per 1 cuvette, with a closure included.
Description
C104CE26 is a quartz micro cuvette for fluorescence work that uses a 10 mm optical path and Four-Way Light optical access around the sample region. This version combines a 5 mm sample channel with a 1.75 mL nominal capacity, so it gives you a wider internal sample region and more filling space than narrower variants in the same body format. A closure is included, and the listed price is for 1 cuvette.
- Path Length
- 10 mm
- Sample Volume (Nominal)
- 1.75 mL
- Closure Type
- Lid
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Micro Cuvette |
| Measurement Mode | Fluorescence Spectroscopy |
| Path Length | 10 mm |
| Light Transmission Configuration | Four-Way Light |
| Optical Window Dimensions | 5 mm |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 1.75 mL |
| External Dimensions | 12.5 × 12.5 × 45 mm |
| Cell Body Dimensions | 12.5 × 12.5 × 45 mm |
| Uncapped Cell Dimensions | 12.5 × 12.5 × 45 mm |
| External Dimensions Scope | Uncapped Cell |
| Material | Quartz |
| Closure Type | Lid |
| Closure Included | Yes |
| Fabrication Method | Molded 83 |
| Detection Channel Width | 5 mm |
Choose this option
Choose C104CE26 when your method needs side optical access and a 10 mm path, but you also want the widest recorded channel in this shown group. The 5 mm sample region makes filling and rinsing more straightforward than a narrower slit-style chamber, while the 1.75 mL nominal capacity gives more headroom for loading the sample without changing to a larger outside body.
What makes this option different
- Four-Way Light geometry gives optical access from more than one side of the sample region, which is useful for fluorescence setups built around side illumination or side detection.
- 10 mm optical path suits methods set up around this standard path length while keeping a micro-cuvette body format.
- 5 mm sample channel gives this option a wider sample region in the cell, which can make top filling, rinsing and visual checking easier than in a narrower channel.
- 1.75 mL nominal capacity provides the largest recorded chamber volume in this group, so this option is the better fit when you want more fill headroom in the same general holder footprint.
- Optical contact construction is the supplier-stated joining term for this exact SKU, with the current MQ fabrication name recorded as Molded 83.
- Closure included means this sale unit includes the cell together with a closure for the top opening.
Using this cell
Fill the cell from the top opening and keep the optical faces clean before measurement. The wider 5 mm channel gives you more direct access when loading the sample, checking for bubbles and rinsing out residue between runs.
Use a consistent orientation in the holder for blanks and samples. The 1.75 mL figure is the nominal capacity of the cell, not a minimum working volume, so if your method relies on a particular beam height or partial-fill condition, check coverage in your own instrument setup before routine use.
First-use check
- Inspect the chamber and optical faces for dust, residue or handling marks.
- Place the empty cuvette in the holder to confirm stable seating and top clearance.
- Run a blank at the intended wavelength before sample measurements.
- After filling, check that the illuminated region is covered and that no bubbles remain in the sample path.
Fit and optical alignment
The stated 12.5 × 12.5 × 45 mm dimensions apply to the uncapped body. Use those dimensions to check holder seating and surrounding clearance, but leave additional space above the cell because the overall size with the closure fitted is not stated here.
Z Height is not stated for this SKU. If your fluorometer, sample holder or beam geometry depends on a defined beam-center height, verify that alignment point before ordering rather than assuming it from the outer body dimensions alone.
Solvents and cleaning
This cuvette is recorded with the supplier term optical contact and the current MQ fabrication name Molded 83. In MQ use, this fabrication is commonly selected for methods where organic-solvent handling or temperature-related workflow planning matters, but suitability still depends on the actual liquid, cleaning routine and the complete wetted assembly of the cell and closure.
Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaning. Rinse promptly after use, and clean the outer optical faces gently with a non-abrasive laboratory wipe.
Included with this option
1 cuvette per listed price unit. Closure included.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We coordinate custom JGS1 quartz production for requirements involving dimensions, optical path length, sample volume, optical windows or Z Height, closures and fabrication details. Send a dimensioned drawing or labelled sketch, together with holder or instrument information, sample conditions and target quantity. Prototype batches typically involve 2–4 cells; feasibility, final specifications, price and production time are confirmed in the project quotation. Discuss your requirements and quote part number C104CE26.
Additional information
| Weight | 30 g |
|---|
You must be logged in to post a review.






Reviews