(C102CS32) Quartz Micro Cuvette, 10 mm Path, 350 µL
Original price was: $19.00.$18.00Current price is: $18.00.
C102CS32 is a JGS1 quartz micro cuvette for UV/Vis spectroscopy with a 10 mm optical path, 350 µL nominal capacity and a 1 mm sample region in a Two-Way Light layout. This adhesive-bonded Standard 80 option is intended for neutral solutions and is supplied as 1 cuvette with a PTFE lid included.
Description
C102CS32 is a JGS1 quartz micro cuvette for UV/Vis work when you need a 10 mm optical path in a smaller 350 µL format. Its 1 mm sample region helps you manage beam coverage more carefully in the filled chamber, and the supplied PTFE lid covers the top after filling. This adhesive-bonded Standard 80 option is sold as 1 cuvette.
- Path Length
- 10 mm
- Sample Volume (Nominal)
- 350 µL
- Closure Type
- Lid
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Micro Cuvette |
| Measurement Mode | UV/Vis Spectroscopy |
| Pack Quantity | 1 Piece |
| Path Length | 10 mm |
| Light Transmission Configuration | Two-Way Light |
| Optical Window Dimensions | 1 mm |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 350 µL |
| External Dimensions | 12.5 × 12.5 × 45 mm |
| Cell Body Dimensions | 12.5 × 12.5 × 45 mm |
| Uncapped Cell Dimensions | 12.5 × 12.5 × 45 mm |
| External Dimensions Scope | Uncapped Cell |
| Material | Quartz |
| Material Grade | JGS1 |
| Closure Type | Lid |
| Closure Material | PTFE |
| Closure Included | Yes |
| Fabrication Method | Standard 80 |
| Detection Channel Width | 1 mm |
Choose this option
Choose C102CS32 when your method uses neutral, water-based samples and you want a compact quartz UV/Vis cell rather than a larger-volume cuvette body. The 10 mm optical path keeps the usual absorbance geometry, while the 350 µL nominal capacity and 1 mm sample region are useful when sample amount and beam placement both matter. The included PTFE lid suits top access handling, provided you also leave room above the cell in your holder setup.
What makes this option different
- JGS1 quartz body for UV/Vis spectroscopy, with a stated 200–2500 nm range.
- 10 mm optical path in a 350 µL nominal-volume micro cuvette format.
- Two-Way Light configuration for transmission measurement through the stated path.
- 1 mm sample region, which makes complete beam coverage important during filling and alignment.
- Adhesive-bonded Standard 80 construction for neutral solutions only.
- PTFE lid included for top closure after filling.
- 12.5 × 12.5 × 45 mm uncapped body dimensions for checking holder fit separately from lid clearance.
Using this cell
Fill the cell so the illuminated region is fully covered during measurement, and keep bubbles away from the optical faces. Use the same orientation for blank and sample measurements so the beam passes through the same part of the sample region each time.
The 350 µL figure is the nominal capacity, not a minimum working volume. Seat the PTFE lid gently after filling, and use it as a cover for measurement rather than as a pressure-rated or transport seal.
First-use check
- Inspect the optical faces, edges and rim for dust, residue or shipping marks.
- Test fit the empty body in the holder and confirm lid clearance above the cell.
- Run a blank at your working wavelength and confirm that the filled sample covers the beam without bubbles.
Fit and optical alignment
The listed 12.5 × 12.5 × 45 mm dimensions apply to the uncapped cell body. Check that your holder accepts that body size and leaves enough clearance above the rim for the lid arrangement.
Z Height is not specified for this SKU. If your instrument depends on a defined beam-center height, check actual holder geometry and beam position before ordering instead of assuming alignment from the outer body dimensions alone.
Solvents and cleaning
This is an adhesive-bonded Standard 80 cuvette. For this exact SKU, that construction matters for sample and cleaning choice: it is intended for neutral solutions only and should be used with room-temperature, water-based methods rather than organic or strongly corrosive media.
Do not soak or rinse this cell with ethanol, and do not use acids, alkalis or organic solvents with this adhesive-bonded option. For cleaning, use methods suitable for neutral aqueous residue, avoid abrasive treatment, and wipe the optical faces gently with non-abrasive optical tissue.
Included with this option
One C102CS32 micro cuvette with a PTFE lid included.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We coordinate custom JGS1 quartz production for requirements involving dimensions, optical path length, sample volume, optical windows or Z Height, closures and fabrication details. Send a dimensioned drawing or labelled sketch, your holder or instrument information, the critical dimensions and tolerances, and your sample conditions. Prototype batches typically involve 2–4 cells; feasibility, final specifications, price and production time are confirmed in the project quotation. Discuss your requirements and reference C102CS32.
Additional information
| Weight | 30 g |
|---|
You must be logged in to post a review.







Reviews
There are no reviews yet.