(C102SR24) Quartz Micro Cuvette, 10 mm Path, 1.4 mL
Original price was: $167.00.$151.00Current price is: $151.00.
C102SR24 is a JGS1 quartz micro cuvette for UV/Vis work with a 10 mm optical path, Two-Way Light geometry and a 4 mm sample-region slit. Its 1.4 mL nominal capacity and supplied stopper make it a closed micro cuvette for methods that need a slightly wider illuminated sample region. Sold as 1 cuvette per listed price unit.
Description
C102SR24 is a JGS1 quartz micro cuvette for UV/Vis measurements that use a standard 10 mm optical path in a compact rectangular cell. This option combines a 4 mm sample region, 1.4 mL nominal capacity and a supplied stopper, making it a practical choice when you want a closed micro cuvette with a wider beam-through sample section than narrower slit versions in the same family.
- Path Length
- 10 mm
- Sample Volume (Nominal)
- 1.4 mL
- Closure Type
- Stopper
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Micro Cuvette |
| Measurement Mode | UV/Vis Spectroscopy |
| Path Length | 10 mm |
| Light Transmission Configuration | Two-Way Light |
| Optical Window Dimensions | 4 mm |
| Sample Volume (Nominal) | 1.4 mL |
| Material | Quartz |
| Material Grade | JGS1 |
| Closure Type | Stopper |
| Closure Included | Yes |
| Detection Channel Width | 4 mm |
Choose this option
Choose C102SR24 when your method uses a 10 mm path length and you want a micro cuvette with a 4 mm sample-region slit. That wider sample region can be useful when you want more room across the illuminated section, while the stopper supports routine closed-cell handling after filling.
What makes this option different
- 10 mm optical path for standard UV/Vis absorbance measurements.
- 4 mm sample-region slit for a wider defined illuminated section.
- 1.4 mL nominal capacity in a micro cuvette body.
- Stopper included for closed sample handling during use.
Using this cell
Fill the cuvette so the beam passes through a fully covered liquid region without bubbles, droplets or dry streaks on the optical faces. Use the same orientation and seating for blank and sample to keep measurement conditions consistent from run to run.
The nominal capacity is helpful for planning sample preparation, but it does not define a minimum working volume. If your instrument uses a fixed beam position, check that the liquid level actually covers the beam during measurement.
First-use check
Inspect the optical faces before first use and rinse the cell with a method-compatible liquid to remove handling residue. Insert the stopper gently, then run a blank to confirm stable placement and a clear optical path.
Fit and optical alignment
This is a Two-Way Light micro cuvette, measured through the two optical faces along the 10 mm path. The 4 mm slit describes the sample-region width, so it is the dimension to review when matching the beam footprint to the illuminated area.
Z Height is not specified for this item, and external fit dimensions are not stated here. If your holder has limited clearance or a fixed beam center, please check compatibility before ordering or send the holder details for review.
Solvents and cleaning
This quartz cuvette is intended for UV/Vis use, but the exact chemical compatibility limits for this SKU are not established here. If your sample or cleaning routine involves more demanding solvent conditions, check suitability before routine use.
Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaning, and wipe the exterior optical faces gently with non-abrasive optical tissue. For background on MQ fabrication options, see Compare fabrication options.
Included with this option
1 cuvette per listed price unit. Closure included.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We can review custom JGS1 quartz versions related to optical path length, sample volume, optical windows, Z Height, closures and fit details. Send a dimensioned drawing or labelled sketch, your holder or instrument information, the sample conditions and the required quantity. Discuss your requirements and quote part number C102SR24.
Additional information
| Weight | 30 g |
|---|
You must be logged in to post a review.





Reviews
There are no reviews yet.