(C102TS4) Quartz Large-Window Cuvette, 10 mm Path, 14 mL
Original price was: $365.00.$329.00Current price is: $329.00.
C102TS4 is a JGS1 quartz large-window cuvette with a 10 mm optical path, Two-Way Light layout and 14 mL nominal capacity. Its M8 threaded top opening gives defined top access for filling and handling, while the wider 42.5 × 12.5 mm base format suits setups that need more body clearance than a slim cell. Sold as 1 cuvette (1 pc/ea).
Description
C102TS4 is a JGS1 quartz large-window cuvette built around a 10 mm optical path and 14 mL nominal capacity. The wider body format and M8 threaded top opening make it a practical choice when your method needs a larger sample chamber, direct top access and enough clearance to handle the cell comfortably in place.
This cuvette uses a Two-Way Light layout for transmission measurements through the stated optical path, and the quartz material is specified for use across 200–2500 nm. The supplier also describes the body as fused integrated construction, which is useful where you want a fixed one-piece cell body for routine filling, rinsing and handling rather than a body assembled from separate plates during normal use.
- Path Length
- 10 mm
- Sample Volume (Nominal)
- 14 mL
- Closure Type
- Screw Cap
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Large-Window Cuvette |
| Measurement Mode | UV/Vis Spectroscopy |
| Pack Quantity | 1 Piece |
| Path Length | 10 mm |
| Light Transmission Configuration | Two-Way Light |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 14 mL |
| External Dimensions | 42.5 × 12.5 × 57 mm |
| Body Height | 45 mm |
| Overall Height with Closure | 61 mm |
| Base Dimensions | 42.5 × 12.5 mm |
| Material | Quartz |
| Material Grade | JGS1 |
| Closure Type | Screw Cap |
| Closure Thread | M8 |
Choose this option
Choose C102TS4 when you need a full-size 10 mm quartz cell with a larger nominal fill volume and a threaded top access point. It suits methods where the sample chamber, the way you introduce and remove liquid, and the physical space around the holder matter just as much as the path length itself.
What makes this option different
- 10 mm optical path in a large-window cuvette format for standard transmission measurements.
- 14 mL nominal capacity, suited to methods that use a larger filled sample region.
- M8 threaded top opening for controlled top access during filling, emptying and rinsing.
- Two-Way Light layout for a defined straight-through optical path.
- JGS1 quartz specified for 200–2500 nm wavelength use.
- Fused integrated construction as the supplier’s stated joining/construction form for the cell body.
- 42.5 × 12.5 mm base format with 45 mm body height; allow for up to 61 mm overall height where a closure is fitted.
Using this cell
Fill the cell from the top opening and keep the liquid level high enough to cover the beam path used by your instrument. During comparative work, use the same orientation for blank and sample, and keep bubbles, droplets and residue away from the optical faces.
The threaded opening helps you work from a defined access point rather than an open wide mouth. That is useful when your filling routine, pipette approach or rinsing sequence needs predictable top access in a fixed holder position.
First-use check
- Inspect the optical faces, rim and threaded opening area for chips, scratches or residue.
- Check that your holder accepts the 42.5 × 12.5 mm base and the vertical clearance your setup needs.
- Rinse with a suitable liquid for your method and run a blank in the same orientation you plan to use for samples.
Fit and optical alignment
The main fit points are the 42.5 × 12.5 mm base, the 45 mm body height and the 57 mm external body dimension, with 61 mm overall height shown for the capped configuration in the source dimensions. Check both holder width and the free space above the cell position, especially if your fixture was designed around a narrower or shorter rectangular cuvette.
Z Height is not stated for this item, so beam-center alignment should be checked against your instrument or holder where that dimension is critical. Two-Way Light describes the optical access category, but it does not by itself establish compatibility with a specific spectrometer, accessory or beam-height standard.
Solvents and cleaning
Quartz is commonly selected for UV and visible wavelength work, but the chemical limits for this exact assembly are not established here. If your sample, rinse solvent or cleaning routine involves aggressive chemicals, prolonged contact or elevated temperature, check suitability before use.
Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaning. Clean the optical faces gently with non-abrasive optical tissue, and see fabrication method of cuvettes for general construction background.
Included with this option
Sold as 1 cuvette (1 pc/ea). A closure is not specified as an included item for this sale unit.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We coordinate custom JGS1 quartz production for requirements involving dimensions, optical path length, sample volume, optical windows, Z Height, closures and connections, and tolerances. Send a dimensioned drawing or labelled sketch together with your holder or instrument details, critical dimensions, sample conditions and target quantity. Prototype batches typically involve 2–4 cells; final specifications, feasibility, price and production time are confirmed in quotation. Discuss your requirements and quote part number C102TS4.
Additional information
| Weight | 100 g |
|---|---|
| Dimensions | 4.25 × 1.25 × 5.7 mm |
You must be logged in to post a review.