(C014CS16) Quartz Screw-Top Cuvette, 1 mm Path, 350 µL
Original price was: $309.00.$279.00Current price is: $279.00.
C014CS16 is a quartz screw-top cuvette for UV/Vis work, combining a 1 mm optical path with a Four-Way Light sample region and 350 µL nominal capacity. The large screw-top opening gives direct top access for filling, while the covered format helps with routine handling between filling and measurement. Sold as 1 cuvette per sales unit.
Description
C014CS16 is a quartz screw-top cuvette for UV/Vis spectroscopy with a 1 mm optical path, a Four-Way Light body and 350 µL nominal capacity. Its large screw-top opening gives direct access from above, and the four-side optical layout gives you more than one side-on beam direction when your holder and measurement geometry allow it.
The optical body measures 35 mm high with a 3.5 × 12.5 mm base section. That compact footprint can be useful where the holder space is limited, but beam height still needs to match your setup because Z Height is not established for this SKU.
- Path Length
- 1 mm
- Sample Volume (Nominal)
- 350 µL
- Closure Type
- Screw Cap
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Screw-Top Cuvette |
| Measurement Mode | UV/Vis Spectroscopy |
| Pack Quantity | 1 Piece |
| Path Length | 1 mm |
| Light Transmission Configuration | Four-Way Light |
| Sample Volume (Nominal) | 350 µL |
| Cell Body Dimensions | 3.5 × 12.5 × 35 mm |
| Body Height | 35 mm |
| Base Dimensions | 3.5 × 12.5 mm |
| Material | Quartz |
| Closure Type | Screw Cap |
| Fabrication Method | Molded 83 |
Choose this option
Choose C014CS16 when you need a short 1 mm path in a covered quartz cell and want top access through a screw-cap opening rather than an open chamber. The 350 µL nominal capacity gives a practical sense of the sample region size, and the Four-Way Light layout is useful where side optical access matters for your UV/Vis arrangement.
What makes this option different
- 1 mm optical path for methods that are set up around a short path length.
- Large screw-top opening for direct top filling and sample access.
- Four-Way Light body with optical access from four vertical sides of the sample region.
- 350 µL nominal capacity in a small covered cell format.
- 3.5 × 12.5 mm base section and 35 mm body height for holder and clearance planning.
- Optical-contact integrated construction as the supplier’s stated construction term for this cell format.
Using this cell
Fill the cell from the top opening and seat the screw cap for covered handling during normal use. Make sure the liquid fully covers the beam path used in your setup, and remove visible bubbles before measurement.
Keep handling to the non-optical surfaces where possible so the light path stays clean. The 350 µL figure is a nominal capacity, not a minimum working volume, so your own method should determine the actual fill level needed for reliable beam coverage.
First-use check
- Inspect the optical faces and opening area for dust, fingerprints or transit marks.
- Rinse the sample-contact area with a suitable liquid for your method.
- Fill with a blank and check that the intended beam path is fully covered.
- Place the cell in the holder and confirm stable support without forcing the body.
Fit and optical alignment
The body dimensions are the practical starting point for fit: a 3.5 × 12.5 mm base section and 35 mm body height. Check these against your holder opening, side supports and any top clearance needed for the screw-cap format.
Four-Way Light means the sample region can be accessed optically from four sides, but it does not by itself establish compatibility with a specific instrument or beam geometry. Z Height is not established for this SKU, so instruments with a fixed beam center should be checked before ordering.
Solvents and cleaning
Molded 83 is the fabrication category used for this quartz cuvette, and the supplier describes the cell as an optical-contact integrated construction. This fabrication category is commonly selected for methods that may involve organic-solvent work, but suitability still depends on the complete assembled cell and the actual chemicals, concentration, temperature and contact time used in your process.
Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaning materials. After use, rinse promptly and clean the optical faces gently with non-abrasive optical tissue.
Included with this option
Sold as 1 cuvette per sales unit. The closure type for this SKU is a screw cap, but the exact included contents are not listed here beyond the selected single-unit sale.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We coordinate custom JGS1 quartz production for requirements involving dimensions, optical path length, sample volume, optical windows or Z Height, closures and connections, fabrication and tolerances. Send a dimensioned drawing or labelled sketch together with holder details, beam position, sample conditions and target quantity. Prototype batches typically involve 2–4 cells; final feasibility, specifications, price and production time are confirmed in the project quotation. Discuss your requirements and quote part number C014CS16.
Additional information
| Weight | 30 g |
|---|---|
| Dimensions | 1.25 × 0.35 × 5.5 mm |
You must be logged in to post a review.






Reviews