(C014CS4) Quartz Screw-Top Cuvette, 1 mm Path, 350 µL, Pack of 2
Original price was: $418.00.$377.00Current price is: $377.00.
C014CS4 is a JGS1 quartz screw-top cuvette with a 1 mm optical path, Two-Way Light configuration and 350 µL nominal capacity. The included PTFE screw cap gives you a covered sample format, and the narrow 12.5 × 3.5 mm body helps when your holder needs a slim rectangular cell. Supplied as a Pack of Two.
Description
C014CS4 is a JGS1 quartz screw-top cuvette for methods that use a 1 mm optical path in a covered sample format. It combines Two-Way Light transmission, a 350 µL nominal capacity and a narrow rectangular body, making it useful when you want a short-path quartz cell with a compact sample region and a cap included. This listing is sold as a Pack of Two.
- Path Length
- 1 mm
- Sample Volume (Nominal)
- 350 µL
- Opening Configuration
- Threaded Neck
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Screw-Top Cuvette |
| Measurement Mode | UV/Vis Spectroscopy |
| Pack Quantity | Pack of 2 |
| Path Length | 1 mm |
| Light Transmission Configuration | Two-Way Light |
| Sample Volume (Nominal) | 350 µL |
| Cell Body Dimensions | 12.5 × 3.5 × 38 mm |
| Overall Height without Closure | 54 mm |
| Body Height | 38 mm |
| Overall Height with Closure | 58 mm |
| Base Dimensions | 12.5 × 3.5 mm |
| Material | Quartz |
| Material Grade | JGS1 |
| Closure Type | Screw Cap |
| Closure Material | PTFE |
| Closure Included | Yes |
| Fabrication Method | Molded 83 |
| Opening Configuration | Threaded Neck |
Choose this option
Choose C014CS4 when your method calls for a 1 mm path and you want a covered cuvette rather than an open-top format. The included PTFE screw cap is the practical difference in daily handling: it covers the sample during transfer and measurement, while the 350 µL nominal capacity keeps the format compact without moving into a demountable or flow-cell assembly.
What makes this option different
- 1 mm optical path for methods specified for a short-path cuvette.
- Two-Way Light configuration supports standard transmission through opposing optical faces.
- Included PTFE screw cap gives a covered sample format for filling, handling and measurement.
- 350 µL nominal capacity provides a defined compact sample region for this cell style.
- 12.5 × 3.5 mm body footprint gives a slim rectangular body for holder-clearance checks.
- Pack of Two preserves the current MQ sale quantity for this SKU.
- Molded 83 fabrication is commonly selected for quartz cuvette work that may involve organic-solvent methods, subject to the conditions of your actual sample and cleaning routine.
Using this cell
Fill through the threaded neck and fit the PTFE screw cap before measurement when your method uses the cell in a covered condition. Keep the optical faces free from fingerprints, bubbles and dried residue, and use the same orientation for blank and sample work when positioning matters.
The 350 µL value is a nominal capacity, not a minimum working volume. In practice, the sample still needs to cover the beam path used by your instrument, so very low fill levels should be checked against your beam position.
First-use check
- Inspect the optical faces for chips, scratches or residue.
- Test fit the empty cell in your holder and check clearance with the cap on if you measure it covered.
- Rinse with a suitable solvent for your method, fill with your blank, and confirm that the sample level covers the beam area.
Fit and optical alignment
The body is 12.5 × 3.5 × 38 mm. The overall height is 54 mm uncapped and 58 mm with the cap fitted, which helps you check both holder fit around the body and vertical clearance above the neck.
Two-Way Light means transmission through opposing optical faces. It does not by itself establish instrument compatibility, and Z Height is not established for this SKU. If your holder has a fixed beam-center height or limited top clearance, check those points before ordering.
Solvents and cleaning
This cuvette is classified under Molded 83. That fabrication is commonly chosen for quartz cuvette applications that may involve organic-solvent methods, but the exact chemical limits of this complete cell assembly are not established here. When your solvent, concentration, temperature or contact time is demanding, check compatibility for the full wetted assembly, including the PTFE cap, before use.
Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaning. Clean the optical faces gently with non-abrasive optical tissue or another suitable soft wipe.
Included with this option
Supplied as a Pack of Two C014CS4 cuvettes with PTFE screw caps.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We also review custom JGS1 quartz cuvette enquiries. If you need a different geometry or related specification, send your drawing or application details and reference C014CS4. Feasibility, quantity, price and production time are confirmed separately in quotation.
Additional information
| Weight | 30 g |
|---|---|
| Dimensions | 1.25 × 0.35 × 5.5 mm |
You must be logged in to post a review.







Reviews
There are no reviews yet.