(C022WS7) Quartz Flow Cell, 2 mm Path, 700 µL
Original price was: $251.00.$226.00Current price is: $226.00.
C022WS7 is a quartz flow cell for UV/Vis spectroscopy with a 2 mm optical path, 700 µL nominal capacity and Two-Way Light geometry. Two opposed tubes in a 5 mm OD / 3 mm ID size make this version useful when you want a simple straight flow connection and need to match the cell to existing tubing. Supplied as 1 flow cell.
Description
C022WS7 is a quartz flow cell for UV/Vis spectroscopy that combines a 2 mm optical path with a 700 µL nominal capacity in a Two-Way Light layout. Its opposed tube connections keep the flow arrangement straightforward, while the 5 mm OD / 3 mm ID tube size gives you a clear starting point for matching tubing and planning how the cell will sit in your line.
- Path Length
- 2 mm
- Sample Volume (Nominal)
- 700 µL
- Opening Configuration
- Two Opposed Fluid Tubes
Selection Specifications
| Product Kind | Flow Cell |
|---|---|
| Cell Type | Flow Cell |
| Measurement Mode | UV/Vis Spectroscopy |
| Pack Quantity | 1 Piece |
| Path Length | 2 mm |
| Light Transmission Configuration | Two-Way Light |
| Sample Volume (Nominal) | 700 µL |
| Cell Body Dimensions | 38 × 4.5 × 12.5 mm |
| Material | Quartz |
| MQ Grade | Molded 83 |
| Port Count | 2 |
| Tube Outer Diameter (OD) | 5 mm |
| Tube Inner Diameter (ID) | 3 mm |
| Fabrication Method | Molded 83 |
| Opening Configuration | Two Opposed Fluid Tubes |
Choose this option
Choose C022WS7 when you need a fixed 2 mm transmission path in a flow-through format and want the connection size defined as part of the purchase. This version is especially useful if your setup already uses tubing around the 5 mm OD / 3 mm ID range and you want a compact optical body rather than a larger holder-style assembly.
What makes this option different
- 2 mm optical path for short-path UV/Vis transmission measurements in a flow cell format.
- Two-Way Light geometry for measurement across one main optical axis rather than side-access layouts.
- 700 µL nominal capacity helps you estimate the cell portion of the wetted volume in your circuit.
- Two opposed fluid tubes, 5 mm OD / 3 mm ID for direct connection planning at both ends of the cell.
Using this cell
Install the cell with the two opposed tubes aligned to your liquid line and fill gradually so the optical region wets evenly. Before measurement, inspect the light path for bubbles, droplets or residue, then run your blank after the cell and the immediate connected line are fully filled.
The listed 700 µL value is the nominal capacity of the cell itself. It does not describe the total liquid volume of connected tubing, fittings or reservoir sections, so full system volume should be planned separately if rinse time or sample changeover matters in your method.
First-use check
- Inspect the quartz body and both tube ends for chips, cracks or visible contamination.
- Confirm that your tubing arrangement suits the 5 mm OD / 3 mm ID connection size.
- Fill slowly with a suitable blank and make sure the optical path is fully wetted and free of trapped bubbles.
- Support the body during installation so the tube connections are not carrying the mechanical load.
Fit and optical alignment
The cell body dimensions are 38 × 4.5 × 12.5 mm for the central optical body, excluding the projecting tubes. Use those body dimensions to check holder contact and clearance around the measurement section, and use the tube size to plan how the line enters and leaves the cell.
Z Height is not stated for this SKU. If your instrument uses a fixed beam position or a close-fitting mount, check beam height and seating directly rather than relying on body size alone.
Solvents and cleaning
This flow cell is listed under Molded 83 fabrication. For flow work, choose sample and cleaning liquids with the complete wetted setup in mind, including any tubing, fittings or seals used elsewhere in your system.
Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaning, and wipe the optical faces gently with non-abrasive optical tissue.
Included with this option
Supplied as 1 flow cell.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We also coordinate custom JGS1 quartz flow cells for changes to dimensions, optical path length, sample volume, optical windows or Z Height, connections, fabrication and tolerances. Send a dimensioned drawing or labelled sketch together with holder or instrument details through the contact page and reference C022WS7.
Additional information
| Weight | 30 g |
|---|
You must be logged in to post a review.






Reviews
There are no reviews yet.