Site Navigation

Quartz 40mm Infrared Cuvette, 14ml, Sintered 83, Two-way Light, PTFE Cap, 1pc/ea, C402CR6

Weight 100 g
SKU: C402CR6

USD$105.00 USD$95.00

In Stock

IR Quartz (JGS3) 40mm infrared cuvette, 14ml, Sintered 83 (>83% transmittance). Two-Way Light. PTFE Cap. 260–3500 nm. SKU: C402CR6.

In Stock
Add to Wishlist
Add to Wishlist
SKU: C402CR6 Categories: , ,

Description

The C402CR6 is a JGS3 IR-grade infrared cuvette with 40mm path length and two-way light optical configuration — two opposing faces are polished to optical grade for standard absorbance measurements. With a 14ml internal volume (40 × 10 × 43 mm chamber), the cell is compatible with most commercial FTIR, NIR, and IR spectrophotometers. Manufactured from JGS3 fused silica with an extended transmittance window of 260–3500 nm — well beyond the 2500 nm cutoff of standard JGS1 quartz. Fabricated using Sintered 83 (>83% transmittance) — high-temperature sintered to fuse quartz panels without adhesive. The friction-fit PTFE cap serves as a dust cover that keeps particulates out of the sample during measurements.

Technical Specifications — IR Infrared Cuvette
Material IR Quartz (JGS3) SKU C402CR6
Path Length 40mm Internal Volume 14ml
Optical Windows 2 (Two-Way Light) Fabrication Sintered 83
Transmittance >83% Wavelength 260–3500 nm
Exterior Dimensions 42.5 × 12.5 × 45 mm Interior Dimensions 40 × 10 × 43 mm
Closure PTFE Cap Package 1pc/ea

Infrared Spectroscopy Applications

FTIR Absorption Spectroscopy — functional-group identification, molecular fingerprinting, and quantitative analysis in the mid-IR
NIR Spectroscopy — overtone and combination-band analysis for moisture, protein, fat, and carbohydrate determination
Pharmaceutical QC — API identification, polymorph screening, and dissolution testing in the NIR/mid-IR range
Petrochemical Analysis — hydrocarbon characterization, fuel-quality monitoring, and lubricant degradation studies
Food & Beverage — sugar, alcohol, moisture, and adulterant detection via NIR/mid-IR absorption
Polymer & Materials Science — functional-group mapping, curing-kinetics monitoring, and degradation analysis
Environmental Monitoring — dissolved organic carbon, oil-in-water, and greenhouse-gas measurements
Biological & Biomedical — tissue characterization, protein secondary-structure analysis, and biofluid screening

Why Two-Way Light?

Two-way light cuvettes have two opposing faces polished to optical grade, providing a single well-defined beam path for standard absorbance measurements. This is the standard configuration for FTIR, NIR, and UV-Vis-NIR spectrophotometers, delivering clean baseline performance and maximum signal-to-noise ratio for quantitative infrared analysis.

Why a PTFE Cap?

The friction-fit PTFE cap serves as a dust cover that keeps particulates and contaminants out of the sample during measurements. PTFE is chemically inert and will not leach absorbing compounds into the sample. While not airtight, the cap reduces evaporation during short measurement cycles and protects the optical surfaces when the cuvette is stored.

Why Sintered 83?

Sintered 83 uses high-temperature sintering to fuse JGS3 IR quartz panels without adhesive, delivering >83% transmittance across 260–3500 nm. The sintered joints are chemically inert and compatible with strong acids, bases, and most organic solvents (excluding HF and aggressive organics such as toluene and acetone). This fabrication is ideal for IR analytical workflows involving harsh chemical matrices where standard glued cells would degrade.

Why JGS3 IR Quartz?

JGS3 is an infrared-grade fused silica with transmittance extending to 3500 nm — significantly beyond the ~2500 nm cutoff of standard JGS1 quartz. This extended window covers the critical O–H, C–H, and N–H overtone and combination bands in the NIR region as well as fundamental absorption bands in the mid-IR. JGS3 is the material of choice for FTIR liquid cells, NIR quantitative analysis, and any spectroscopic measurement where mid-infrared transparency is required.

Usage Tips

  • Rinse with a compatible solvent (e.g., ethanol or the measurement solvent) before first use to remove any residual particles.
  • Do not use abrasive materials or brushes on the polished optical faces — wipe gently with lens tissue.
  • Compatible with strong acids, bases, and most organic solvents (excluding HF and aggressive organics such as toluene and acetone).
  • Store in the original protective case to prevent scratches on the optical windows.
  • For baseline correction, fill with your reference solvent and run a blank before sample measurements.
  • Compatible with Thermo Fisher, Bruker, PerkinElmer, Shimadzu, JASCO, Agilent, and most FTIR/NIR instruments.
Custom Orders
Need a non-standard path length, volume, window configuration, or closure type? We manufacture IR quartz cuvettes to your exact specifications. Request a custom quote.
Disclaimer: Specifications are nominal values measured under standard laboratory conditions. Actual transmittance may vary slightly with wavelength and sample conditions. Images are representative; minor cosmetic variations between production batches are normal and do not affect optical performance.

Additional information

Weight 100 g

Reviews

There are no reviews yet.

Be the first to review “Quartz 40mm Infrared Cuvette, 14ml, Sintered 83, Two-way Light, PTFE Cap, 1pc/ea, C402CR6”

You may also like…

Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • SKU
  • Rating
  • Price
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Weight
  • Dimensions
  • Additional information
  • Attributes
  • Custom attributes
  • Custom fields
Click outside to hide the compare bar
Compare