(C062CS1) Quartz Standard Cuvette, 6 mm Path, 540 µL
Original price was: $27.00.$25.00Current price is: $25.00.
C062CS1 is a JGS1 quartz standard cuvette with a 6 mm optical path, a 540 µL nominal capacity and an open-top body for direct filling. Its Two-Way Light layout suits through-beam measurements where you want a compact cell and straightforward top access. Supplied as 1 cuvette per listed price unit.
Description
C062CS1 is a compact JGS1 quartz standard cuvette built around a 6 mm optical path and a 540 µL nominal capacity. The open-top format gives direct access to the sample area for filling, emptying and cleaning, while the Two-Way Light layout keeps the optical path straightforward for through-beam measurements.
This option is useful when your method already specifies a 6 mm path and your holder can accept a small uncapped body. Its 7 × 8 × 27 mm uncapped size is often easier to place where surrounding clearance is limited, but beam height still needs to be checked in your own setup.
- Path Length
- 6 mm
- Sample Volume (Nominal)
- 540 µL
- Opening Configuration
- Open Top
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Standard Cuvette |
| Measurement Mode | Biochemical Analysis |
| Path Length | 6 mm |
| Light Transmission Configuration | Two-Way Light |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 540 µL |
| External Dimensions | 7 × 8 × 27 mm |
| Uncapped Cell Dimensions | 7 × 8 × 27 mm |
| External Dimensions Scope | Uncapped Cell |
| Body Height | 27 mm |
| Base Dimensions | 7 × 8 mm |
| Material | Quartz |
| Material Grade | JGS1 |
| Fabrication Method | Molded 83 |
| Opening Configuration | Open Top |
Choose this option
Choose C062CS1 when you need a 6 mm path in a standard rectangular quartz cell and want direct top access instead of a capped or flow-through arrangement. The 540 µL nominal capacity fits small-volume bench work, while the compact uncapped body helps when holder space is tighter than with longer standard cells.
What makes this option different
- 6 mm optical path for methods written around that fixed transmission length.
- 540 µL nominal capacity in a small standard cell format for direct filling from above.
- Open-top body for simple loading, emptying and rinse access without threaded fittings or a removable plate assembly.
- Two-Way Light configuration for transmission through the opposing optical faces.
- JGS1 quartz construction with Molded 83 fabrication mapped from the current construction evidence.
- 7 × 8 × 27 mm uncapped dimensions to check holder seating and top clearance in your instrument.
Using this cell
Fill the cell from the top and make sure the liquid level covers the measurement region used by your instrument. Remove visible bubbles before reading, and keep the same orientation for blank and sample so the beam passes through the same faces each time.
The 540 µL figure is a nominal capacity, not a stated minimum working volume. Handle the cuvette by the non-optical surfaces where possible, and keep the measurement faces free from fingerprints and residue.
First-use check
Inspect the optical faces for dust or handling marks, place the empty cell in the holder to confirm seating, then run a blank with your intended liquid before routine measurements. This quick check helps confirm both beam coverage and practical filling level in your own instrument.
Fit and optical alignment
The listed 7 × 8 × 27 mm dimensions apply to the uncapped cell body. If your setup uses any separate closure or holder parts above the cell, leave enough extra clearance for those components because they are not included in the stated body size.
Z Height is not stated for this item. If your instrument has a fixed beam center or a holder designed around a specific optical axis height, check that alignment before ordering.
Solvents and cleaning
Molded 83 is commonly selected for methods that may involve organic solvents or heated use, but your actual sample, temperature, contact time and any closure materials still matter for the complete assembly. This page does not establish a full chemical-compatibility or pressure rating for the exact assembled setup.
Do not use hydrofluoric acid with quartz. Avoid hot strong alkalis and abrasive cleaning, and wipe the optical faces gently with non-abrasive optical tissue.
Included with this option
1 cuvette per listed price unit. Confirm supplied closure details before ordering if your setup requires one.
Availability and ordering
Order this listed specification directly, or ask about current availability and dispatch. If your delivery date is important, ask before checkout; preparation or production time is separate from transit and customs clearance.
Discuss a custom version
For a different design, send a drawing or describe the change you need. Custom JGS1 quartz enquiries are assessed separately from this listed specification.
Additional information
| Weight | 30 g |
|---|
You must be logged in to post a review.







Reviews
There are no reviews yet.