(C402CE2) Quartz Large-Window Cuvette, 10 mm Path, 14 mL
Original price was: $147.00.$133.00Current price is: $133.00.
C402CE2 is a JGS1 quartz Large-Window Cuvette with a 10 mm optical path, straight-through Two-Way Light access and a 14 mL nominal capacity. Its open-top body suits direct filling for transmission measurements across the stated 200 to 2500 nm range. Sold as 1 cuvette per price unit, with a closure included.
Description
C402CE2 is a JGS1 quartz Large-Window Cuvette for straight-through transmission work with a 10 mm optical path. The open-top body gives direct access for filling and rinsing, while the 14 mL nominal capacity and larger rectangular format suit methods that use a fuller sample chamber rather than a compact micro-volume layout. This option is sold as 1 cuvette per price unit, with a closure included.
- Path Length
- 10 mm
- Sample Volume (Nominal)
- 14 mL
- Opening Configuration
- Open Top
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Large-Window Cuvette |
| Measurement Mode | UV/Vis Spectroscopy |
| Path Length | 10 mm |
| Light Transmission Configuration | Two-Way Light |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 14 mL |
| External Dimensions | 42.5 × 12.5 × 45 mm |
| Body Height | 45 mm |
| Base Dimensions | 42.5 × 12.5 mm |
| Material | Quartz |
| Material Grade | JGS1 |
| Closure Included | Yes |
| Opening Configuration | Open Top |
Choose this option
Choose C402CE2 when you need a larger-body quartz cell with a standard 10 mm path and direct top access. The large-window format is useful when your method is built around a fuller sample chamber, and the straight-through optical layout keeps selection simple for routine transmission measurements rather than side-access arrangements.
What makes this option different
- 10 mm optical path for standard straight-through transmission measurement through the body.
- Two-Way Light layout with opposed transmission access, suited to beam entry and exit across the defined path rather than side-looking optical access.
- Open-top filling access for direct sample addition, emptying and rinsing from above.
- 14 mL nominal capacity in a larger sample chamber for methods that are not built around ultra-low fill volumes.
- JGS1 quartz construction for the stated 200 to 2500 nm use range.
- Fused integrated construction in the supplier’s stated HELLMA process terminology, giving this option a joined quartz body construction rather than a separately assembled accessory set.
- Closure included with the cuvette price unit.
Using this cell
Fill the cell from the top opening and orient it so the measurement beam passes straight through the opposed optical faces along the 10 mm path. For routine work, handle the cuvette by the outer body surfaces where possible and avoid touching the optical faces before measurement.
The stated 14 mL value is a nominal capacity, not a minimum working volume. If your method depends on liquid height over the beam, confirm that your fill level covers the actual measurement zone in your instrument.
First-use check
Inspect the cuvette on arrival for chips, scratches or residue on the optical faces and rim. Before introducing sample, place the dry cell in your holder to confirm seating, orientation and top clearance, then run your normal blank under the intended measurement conditions.
Fit and optical alignment
The external body dimensions are 42.5 × 12.5 × 45 mm. This is a larger rectangular cuvette body, so check holder width, depth and top clearance if your instrument or fixture is arranged for a narrower format or limited space above the cell.
Two-Way Light here means straight-through optical access through the body, not side fluorescence access. Z Height is not specified for this listing, so instruments with a fixed beam height or tight vertical alignment should be checked against the actual beam position before ordering.
Solvents and cleaning
This cuvette is made from quartz. Avoid hydrofluoric acid, hot strong alkalis and abrasive cleaning methods. Use non-abrasive optical tissue or a lint-free wipe on the exterior optical faces.
The supplier describes this option as a fused integrated construction in its HELLMA process terminology. That construction description helps identify the body style, but it does not by itself establish a full chemical compatibility list for every solvent or cleaning condition. If your method involves aggressive chemicals, elevated temperature or prolonged soaking, review those conditions before use. For general fabrication background, see the MQ fabrication guide.
Included with this option
1 cuvette per listed price unit. Closure included.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We coordinate custom JGS1 quartz projects for requirements involving dimensions, optical path length, sample volume, optical windows or Z Height, closures and connections, and tolerance requests. Send a dimensioned drawing or labelled sketch together with your holder or instrument details, application wavelength, sample chemistry, temperature and target timing. Discuss your requirements and mention part number C402CE2.
Additional information
| Weight | 100 g |
|---|
You must be logged in to post a review.







Reviews
There are no reviews yet.